4,844 research outputs found

    Spectral Line Imaging Observations of 1E0102.2-7219

    Get PDF
    E0102-72 is the second brightest X-ray source in the Small Magellanic Cloud and the brightest supernova remnant in the SMC. We observed this SNR for ~140 ksec with the High Energy Transmission Gratings (HETG) aboard the Chandra X-ray Observatory. The small angular size and high surface brightness make this an excellent target for HETG and we resolve the remnant into individual lines. We observe fluxes from several lines which include O VIII Lyα\alpha, Lyβ\beta, and O VII along with several lines from Ne X, Ne IX and Mg XII. These line ratios provide powerful constraints on the electron temperature and the ionization age of the remnant.Comment: To appear in "Young Supernova Remnants" (11th Annual Astrophysics Conference in Maryland), S. S. Holt & U. Hwang (eds), AIP, New York (2001

    Social presence in the 21st Century: an adjustment to the Community of Inquiry framework

    Get PDF
    The Community of Inquiry framework, originally proposed by Garrison, Anderson and Archer (2000) identifies teaching, social and cognitive presences as central to a successful online educational experience. This article presents the findings of a study conducted in Uruguay between 2007 and 2010. The research aimed to establish the role of cognitive, social and teaching presences in the professional development of 40 English language teachers on Continuous Professional Development (CPD) programmes delivered in blended learning settings. The findings suggest that teaching presence and cognitive presence have themselves 'become social'. The research points to social presence as a major lever for engagement, sense-making and peer support. Based on the patterns identified in the study, this article puts forward an adjustment to the Community of Inquiry framework, which shows social presence as more prominent within the teaching and cognitive constructs than the original version of the framework suggests

    Scapegoat: John Dewey and the character education crisis

    Get PDF
    Many conservatives, including some conservative scholars, blame the ideas and influence of John Dewey for what has frequently been called a crisis of character, a catastrophic decline in moral behavior in the schools and society of North America. Dewey’s critics claim that he is responsible for the undermining of the kinds of instruction that could lead to the development of character and the strengthening of the will, and that his educational philosophy and example exert a ubiquitous and disastrous influence on students’ conceptions of moral behavior. This article sets forth the views of some of these critics and juxtaposes them with what Dewey actually believed and wrote regarding character education. The juxtaposition demonstrates that Dewey neither called for nor exemplified the kinds of character-eroding pedagogy his critics accuse him of championing; in addition, this paper highlights the ways in which Dewey argued consistently and convincingly that the pedagogical approaches advocated by his critics are the real culprits in the decline of character and moral education

    From representation to emergence: complexity's challenge to the epistemology of schooling

    Get PDF
    In modern,Western societies the purpose of schooling is to ensure that school-goers acquire knowledge of pre-existing practices, events, entities and so on.The knowledge that is learned is then tested to see if the learner has acquired a correct or adequate understanding of it. For this reason, it can be argued that schooling is organised around a representational epistemology: one which holds that knowledge is an accurate representation of something that is separate from knowledge itself. Since the object of knowledge is assumed to exist separately from the knowledge itself, this epistemology can also be considered ‘spatial.’ In this paper we show how ideas from complexity have challenged the ‘spatial epistemology’ of representation and we explore possibilities for an alternative ‘temporal’ understanding of knowledge in its relationship to reality. In addition to complexity, our alternative takes its inspiration from Deweyan ‘transactional realism’ and deconstruction. We suggest that ‘knowledge’ and ‘reality’ should not be understood as separate systems which somehow have to be brought into alignment with each other, but that they are part of the same emerging complex system which is never fully ‘present’ in any (discrete) moment in time. This not only introduces the notion of time into our understanding of the relationship between knowledge and reality, but also points to the importance of acknowledging the role of the ‘unrepresentable’ or ‘incalculable’. With this understanding knowledge reaches us not as something we receive but as a response, which brings forth new worlds because it necessarily adds something (which was not present anywhere before it appeared) to what came before. This understanding of knowledge suggests that the acquisition of curricular content should not be considered an end in itself. Rather, curricular content should be used to bring forth that which is incalculable from the perspective of the present. The epistemology of emergence therefore calls for a switch in focus for curricular thinking, away from questions about presentation and representation and towards questions about engagement and response

    Is there a gender difference in noninvasive coronary imaging? Multislice computed tomography for noninvasive detection of coronary stenoses

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Multislice computed tomography (MSCT) coronary angiography is the foremost alternative to invasive coronary angiography.</p> <p>Methods</p> <p>We sought to compare the diagnostic accuracy of MSCT in female and male patients with suspected coronary disease. Altogether 50 women and 95 men underwent MSCT with 0.5 mm detector collimation. Coronary artery stenoses of at least 50% on conventional coronary angiography were considered significant.</p> <p>Results</p> <p>The coronary vessel diameters of all four main coronary artery branches were significantly larger in men than in women. The diagnostic accuracy of MSCT in identifying patients with coronary artery disease was significantly lower for women (72%) compared with men (89%, <it>p </it>< 0.05). Also sensitivity (70% vs. 95%), positive predictive value (64% vs. 93%), and the rate of nondiagnostic examinations (14% vs. 4%, all: <it>p </it>< 0.05) were significantly worse for women. The effective radiation dose of MSCT coronary angiography was significantly higher in the examination of women (13.7 ± 1.2 mSv) than of men (11.7 ± 0.9 mSv, <it>p </it>< 0.001), mainly as a result of the fact that the radiosensitive female breast (contributing 24.5% of the dose in women) is in the x-ray path.</p> <p>Conclusion</p> <p>Noninvasive coronary angiography with MSCT might be less accurate and sensitive for women than men. Also, women are exposed to a significantly higher effective radiation dose than men.</p

    emiT: an apparatus to test time reversal invariance in polarized neutron decay

    Get PDF
    We describe an apparatus used to measure the triple-correlation term (\D \hat{\sigma}_n\cdot p_e\times p_\nu) in the beta-decay of polarized neutrons. The \D-coefficient is sensitive to possible violations of time reversal invariance. The detector has an octagonal symmetry that optimizes electron-proton coincidence rates and reduces systematic effects. A beam of longitudinally polarized cold neutrons passes through the detector chamber, where a small fraction beta-decay. The final-state protons are accelerated and focused onto arrays of cooled semiconductor diodes, while the coincident electrons are detected using panels of plastic scintillator. Details regarding the design and performance of the proton detectors, beta detectors and the electronics used in the data collection system are presented. The neutron beam characteristics, the spin-transport magnetic fields, and polarization measurements are also described.Comment: 15 pages, 13 figure

    High Resolution X-Ray Spectra of Capella: Initial Results from the Chandra High Energy Transmission Grating Spectrometer

    Get PDF
    High resolution spectra of the active binary Capella (G8 III + G1 III) covering the energy range 0.4-8.0 keV (1.5-30 Angstroms) show a large number of emission lines, demonstrating the performance of the HETGS. A preliminary application of plasma diagnostics provides information on coronal temperatures and densities. Lines arising from different elements in a range of ionization states indicate that Capella has plasma with a broad range of temperatures, from log T = 6.3 to 7.2, generally consistent with recent results from observations with the Extreme Ultraviolet Explorer (EUVE) and the Advanced Satellite for Cosmology and Astrophysics (ASCA). The electron density is determined from He-like O VII lines, giving the value N_e=10^10 cm^-3 at T_e=2*10^6 K; He-like lines formed at higher temperatures give only upper limits to the electron density. The density and emission measure from O VII lines together indicate that the coronal loops are significantly smaller than the stellar radius.Comment: 9 pages, 3 figures (1 color) accepted for ApJ

    Decentring emotion regulation: from emotion regulation to relational emotion

    Get PDF
    YesThis article takes a critical approach to emotion regulation suggesting that the concept needs supplementing with a relational position on the generation and restraint of emotion. I chart the relational approach to emotion, challenging the ‘two-step’ model of emotion regulation. From this, a more interdisciplinary approach to emotion is developed using concepts from social science to show the limits of instrumental, individualistic and cognitivist orientations in the psychology of emotion regulation, centred on appraisal theory. Using a social interactionist approach I develop an ontological position in which social relations form the fundamental contexts in which emotions are generated, toned, and restrained, so that regulation is decentred and seen as just one moment or aspect in the relational patterning of emotion

    A Statistical Study of the Force Balance and Structure in the Flux Ropes in Mercury’s Magnetotail

    Full text link
    This study presents a statistical investigation of the force balance and structures in the flux ropes in Mercury’s magnetotail plasma sheet by using the measurements of MErcury Surface, Space ENviroment, GEochemistry, and Ranging (MESSENGER). One hundred sixty-eight flux ropes were identified from the 14 hot seasons of MESSENGER from 11 March 2011 to 30 April 2015, and 143 of them show clear magnetic field enhancements with the core field being -20% higher than the background magnetic field. The investigation on the force balance of these 143 flux ropes shows that magnetic pressure gradient force cannot be solely balanced by magnetic tension force, implying that thermal plasma pressure gradient force cannot be neglected in the flux ropes. We employ a non-force-free model considering the contribution of thermal pressure to resolve the physical properties of flux ropes in Mercury’s magnetotail. Twenty-eight flux ropes are obtained through the fitting to the non-force-free model. The flux ropes are found to be consistent with the flattened structures, in which the mean semimajor is -851 km and semiminor is -333 km, both are several times the local proton inertial length. The average core field is estimated to be -57.5 nT, and flux content is -0.019 MWb, much larger than the previous results obtained from force-free flux rope model. The importance of thermal pressure gradient in the force balance of the flux ropes and the flattened structure indicates that the flux ropes in Mercury’s magnetotail plasma sheet are mostly in early stage of the evolution, and still contain enough plasma to affect their magnetic structures.Key PointsThermal pressure gradient is significant for the flux ropes in Mercury’s magnetotailNon-force-free modeling reveals the flatten structure and much higher magnetic flux of the flux ropes different from the previous studiesFlux ropes in this study should be in their early stage of evolution and could be strongly affected by thermal pressurePeer Reviewedhttps://deepblue.lib.umich.edu/bitstream/2027.42/151305/1/jgra55044_am.pdfhttps://deepblue.lib.umich.edu/bitstream/2027.42/151305/2/jgra55044.pd

    Patient Acceptance of Noninvasive and Invasive Coronary Angiography

    Get PDF
    BACKGROUND: Noninvasive angiography using multislice computed tomography (MSCT) is superior to magnetic resonance imaging (MRI) for detection of coronary stenoses. We compared patient acceptance of these two noninvasive diagnostic tests and invasive conventional coronary angiography (Angio). METHODS AND FINDINGS: A total of 111 consecutive patients with suspected coronary artery disease underwent MSCT, MRI, and Angio. Subsequently, patient acceptance of the three tests was evaluated with questionnaires in all patients. The main acceptance variables were preparation and information prior to the test, degree of concern, comfort, degree of helplessness, pain (on visual analog scales), willingness to undergo the test again, and overall satisfaction. Preparation for each test was not rated significantly differently, whereas patients were significantly more concerned about Angio than the two noninvasive tests (p<0.001). No pain during MSCT, MRI, and Angio as assessed on visual analog scales (0 to 100) was reported by 99, 93, and 31 patients, respectively. Among the 82 patients who felt pain during at least one procedure, both CT (0.9±4.5) and MRI (5.2±16.6) were significantly less painful than Angio (24.6±23.4, both p<0.001). MSCT was considered significantly more comfortable (1.49±0.64) than MRI (1.75±0.81, p<0.001). In both the no-revascularization (55 patients) and the revascularization group (56 patients), the majority of the patients (73 and 71%) would prefer MSCT to MRI and Angio for future imaging of the coronary arteries. None of the patients indicated to be unwilling to undergo MSCT again. The major advantages patients attributed to MSCT were its fast, uncomplicated, noninvasive, and painless nature. CONCLUSIONS: Noninvasive coronary angiography with MSCT is considered more comfortable than MRI and both MSCT and MRI are less painful than Angio. Patient preference for MSCT might tip the scales in favor of this test provided that the diagnostic accuracy of MSCT can be shown to be high enough for clinical application
    corecore