33 research outputs found

    FRP reinforcement for concrete structures: state-of-the-art review of application and design

    Get PDF
    Fiber reinforced polymers (FRPs) are considered to be a promising alternative to steel reinforcement, especially in concrete structures subjected to an aggressive environment or to the effects of electromagnetic fields. Although attempts to develop effective reinforcement have been followed, the application of FRPs remains limited by the solution to simple structural problems that mainly appear due to the absence of design codes, significant variation in the material properties of FRP composites and limited knowledge gained by engineers as regards the application aspects of FRP composites and structural mechanics of concrete elements reinforced with FRPs. To fill the latter gap, the current state-of-the-art report is dedicated to present recent achievements in FRPs applying practice to a broad engineers’ community. The report also revises the manufacturing process, material properties, the application area and design peculiarities of concrete elements reinforced with FRP composites. Along the focus on internal reinforcement, the paper overviews recent practices of applying FRP reinforced concrete (RC) elements in structural engineering. The review highlights the main problems restricting the application of FRPs in building industry and reveals the problematic issues (related to the material properties of the FRP) important for designing RC following the formulation of targets for further research

    Detection of inspiratory recruitment of atelectasis by automated lung sound analysis as compared to four-dimensional computed tomography in a porcine lung injury model

    Get PDF
    Background: Cyclic recruitment and de-recruitment of atelectasis (c-R/D) is a contributor to ventilator-induced lung injury (VILI). Bedside detection of this dynamic process could improve ventilator management. This study investigated the potential of automated lung sound analysis to detect c-R/D as compared to four-dimensional computed tomography (4DCT). Methods: In ten piglets (25 ± 2 kg), acoustic measurements from 34 thoracic piezoelectric sensors (Meditron ASA, Norway) were performed, time synchronized to 4DCT scans, at positive end-expiratory pressures of 0, 5, 10, and 15 cmH2O during mechanical ventilation, before and after induction of c-R/D by surfactant washout. 4DCT was post-processed for within-breath variation in atelectatic volume (Δ atelectasis) as a measure of c-R/D. Sound waveforms were evaluated for: 1) dynamic crackle energy (dCE): filtered crackle sounds (600–700 Hz); 2) fast Fourier transform area (FFT area): spectral content above 500 Hz in frequency and above −70 dB in amplitude in proportion to the total amount of sound above −70 dB amplitude; and 3) dynamic spectral coherence (dSC): variation in acoustical homogeneity over time. Parameters were analyzed for global, nondependent, central, and dependent lung areas. Results: In healthy lungs, negligible values of Δ atelectasis, dCE, and FFT area occurred. In lavage lung injury, the novel dCE parameter showed the best correlation to Δ atelectasis in dependent lung areas (R2 = 0.88) where c-R/D took place. dCE was superior to FFT area analysis for each lung region examined. The analysis of dSC could predict the lung regions where c-R/D originated. Conclusions: c-R/D is associated with the occurrence of fine crackle sounds as demonstrated by dCE analysis. Standardized computer-assisted analysis of dCE and dSC seems to be a promising method for depicting c-R/D

    International Consensus Based Review and Recommendations for Minimum Reporting Standards in Research on Transcutaneous Vagus Nerve Stimulation (Version 2020)

    Get PDF
    Given its non-invasive nature, there is increasing interest in the use of transcutaneous vagus nerve stimulation (tVNS) across basic, translational and clinical research. Contemporaneously, tVNS can be achieved by stimulating either the auricular branch or the cervical bundle of the vagus nerve, referred to as transcutaneous auricular vagus nerve stimulation(VNS) and transcutaneous cervical VNS, respectively. In order to advance the field in a systematic manner, studies using these technologies need to adequately report sufficient methodological detail to enable comparison of results between studies, replication of studies, as well as enhancing study participant safety. We systematically reviewed the existing tVNS literature to evaluate current reporting practices. Based on this review, and consensus among participating authors, we propose a set of minimal reporting items to guide future tVNS studies. The suggested items address specific technical aspects of the device and stimulation parameters. We also cover general recommendations including inclusion and exclusion criteria for participants, outcome parameters and the detailed reporting of side effects. Furthermore, we review strategies used to identify the optimal stimulation parameters for a given research setting and summarize ongoing developments in animal research with potential implications for the application of tVNS in humans. Finally, we discuss the potential of tVNS in future research as well as the associated challenges across several disciplines in research and clinical practice

    Inventory of current EU paediatric vision and hearing screening programmes

    Get PDF
    Background: We examined the diversity in paediatric vision and hearing screening programmes in Europe. Methods: Themes relevant for comparison of screening programmes were derived from literature and used to compile three questionnaires on vision, hearing and public-health screening. Tests used, professions involved, age and frequency of testing seem to influence sensitivity, specificity and costs most. Questionnaires were sent to ophthalmologists, orthoptists, otolaryngologists and audiologists involved in paediatric screening in all EU fullmember, candidate and associate states. Answers were cross-checked. Results: Thirty-nine countries participated; 35 have a vision screening programme, 33 a nation-wide neonatal hearing screening programme. Visual acuity (VA) is measured in 35 countries, in 71% more than once. First measurement of VA varies from three to seven years of age, but is usually before the age of five. At age three and four picture charts, including Lea Hyvarinen are used most, in children over four Tumbling-E and Snellen. As first hearing screening test otoacoustic emission (OAE) is used most in healthy neonates, and auditory brainstem response (ABR) in premature newborns. The majority of hearing testing programmes are staged; children are referred after one to four abnormal tests. Vision screening is performed mostly by paediatricians, ophthalmologists or nurses. Funding is mostly by health insurance or state. Coverage was reported as >95% in half of countries, but reporting was often not first-hand. Conclusion: Largest differences were found in VA charts used (12), professions involved in vision screening (10), number of hearing screening tests before referral (1-4) and funding sources (8)

    Balancing Ethical Principles in Emergency Medicine Research

    No full text

    On the reconstruction of parameters of quasi-Gaussian pump beams during transient SBS

    No full text
    The radii and radii of curvature of Stokes stimulated Brillouin scattering (SBS) beams are measured by the method of moments for smooth nearly Gaussian focused pump beams with the propagation coefficient M2σp<1.2. It is shown that in the case of sufficiently deeply focused pump radiation, the propagation coefficient M2σS of Stokes beams near the threshold of the transient SBS is smaller than M2σp and approaches it with increasing the pump pulse energy. It is also found that the radii of Stokes beams at the output from a nonlinear medium are smaller than the radii of pump beams, while the radii of wave-front curvature are close (in modulus) to the radii of wave-front curvature for pump beamsFizikos institutasVytauto Didžiojo universiteta

    Mechanical Behavior of Steel Fiber-Reinforced Concrete Beams Bonded with External Carbon Fiber Sheets

    No full text
    This study investigates the mechanical behavior of steel fiber-reinforced concrete (SFRC) beams internally reinforced with steel bars and externally bonded with carbon fiber-reinforced polymer (CFRP) sheets fixed by adhesive and hybrid jointing techniques. In particular, attention is paid to the load resistance and failure modes of composite beams. The steel fibers were used to avoiding the rip-off failure of the concrete cover. The CFRP sheets were fixed to the concrete surface by epoxy adhesive as well as combined with various configurations of small-diameter steel pins for mechanical fastening to form a hybrid connection. Such hybrid jointing techniques were found to be particularly advantageous in avoiding brittle debonding failure, by promoting progressive failure within the hybrid joints. The use of CFRP sheets was also effective in suppressing the localization of the discrete cracks. The development of the crack pattern was monitored using the digital image correlation method. As revealed from the image analyses, with an appropriate layout of the steel pins, brittle failure of the concrete-carbon fiber interface could be effectively prevented. Inverse analysis of the moment-curvature diagrams was conducted, and it was found that a simplified tension-stiffening model with a constant residual stress level at 90% of the strength of the SFRC is adequate for numerically simulating the deformation behavior of beams up to the debonding of the CFRP sheets

    Prediction of fuel channel-graphite gas-gap behaviour in RBMK reactors

    No full text
    To maintain thermal contact between the fuel assembly and the graphite moderator, RBMK design reactors employ graphite split rings, which are alternatively tight on the pressure tube or tight on the graphite brick central bore. The split in the graphite rings allows a helium / nitrogen gas mixture flow up the fuel channel. This prevents oxidation of the graphite and can be sampled to detect pressure tube leaks. The initial clearance between the rings and pressure tube or graphite brick is approximately 2.7 mm (1.35mm each side). Due to material property changes of the pressure tubes and graphite during operation of the reactor, the size of the clearance between the rings and the pressure tube/brick, called the “gas-gap”, varies. Closure of these gaps has been identified as a possible safety case issue by reactor designers and by independent reviews carried out as part of TACIS reviews and as part of the Ignalina Safety Analysis Report. The reasons for this are that gas-gap closure would cause the pressure tube to be tightly gripped by the graphite bricks via the split rings, which could lead to: · Extra loading on the upper pressure tube zirconium / steel transition joint, particularly during shut down and emergency transients · Splitting of the graphite brick leading to loss thermal contact between the pressure tube and graphite. As approximately 5.6% of the heat in graphite moderated reactor is generated within the moderator through neutron and gamma-heating loss of thermal contact would result in higher graphite temperatures accelerating the rate of graphite expansion and hence increasing the loading of the core radial restraint.· Graphite debris may become lodged in inter brick gaps leading to increased axial pressure tube loading during shut down and emergency transientsLietuvos energetikos institutasVytauto Didžiojo universiteta

    ESR spectroscopy of alanine impacted by high energy irradiations for wide range dosimetry

    No full text
    The ESR spectrometry, based on alanine dosimeters, is a standard tool for dosimetry of different type ionizing radiations. The calibrated dosimeters and ESR readers operate rather reliably in the dose range up to 200 kGy. In this study, the ESR spectrometry of stable free radicals in alanine, induced by penetrative X- and γ-rays as well as neutron and stopped proton irradiations covering the dose range from a few Gy to a few MGy, has been performed in order to create the generalized calibration function for the wide range dosimetry. The simulations based on the cumulative generation of ESR active stable radicals R1, R2 and R3 enabled us to derive the generalized calibration model ascribed to the irradiation fluence from 10^10 to 2 × 10^16 particle/cm^2 normalized using 1 MeV neutron equivalent
    corecore