109 research outputs found

    Apnoeic oxygenation for emergency anaesthesia of pre-hospital trauma patients

    Get PDF
    Background Efficient and timely airway management is universally recognised as a priority for major trauma patients, a proportion of whom require emergency intubation in the pre-hospital setting. Adverse events occur more commonly in emergency airway management, and hypoxia is relatively frequent. The aim of this study was to establish whether passive apnoeic oxygenation was effective in reducing the incidence of desaturation during pre-hospital emergency anaesthesia. Methods A prospective before-after study was performed to compare patients receiving standard care and those receiving additional oxygen via nasal prongs. The primary endpoint was median oxygen saturation in the peri-rapid sequence induction period, (2 minutes pre-intubation to 2 minutes post-intubation) for all patients. Secondary endpoints included the incidence of hypoxia in predetermined subgroups. Results Of 725 patients included; 188 patients received standard treatment and 537 received the intervention. The overall incidence of hypoxia (first recorded SpO2 < 90%) was 16.7%; 10.9% had SpO2 < 85%. 98/725 patients (13.5%) were hypoxic post-intubation (final SpO2 < 90% 10 minutes post-intubation). Median SpO2 was 100% vs. 99% for the standard vs. intervention group. There was a statistically significant benefit from apnoeic oxygenation in reducing the frequency of peri-intubation hypoxia (SpO2  95%, p = 0.0001. The other significant benefit was observed in the recovery phase for patients with severe hypoxia prior to intubation. Conclusion Apnoeic oxygenation did not influence peri-intubation oxygen saturations, but it did reduce the frequency and duration of hypoxia in the post-intubation period. Given that apnoeic oxygenation is a simple low-cost intervention with a low complication rate, and that hypoxia can be detrimental to outcome, application of nasal cannulas during the drug-induced phase of emergency intubation may benefit a subset of patients undergoing emergency anaesthesia.publishedVersio

    The success of pre-hospital tracheal intubation by different pre-hospital providers: a systematic literature review and meta-analysis

    Get PDF
    Background: Pre-hospital basic airway interventions can be ineffective at providing adequate oxygenation and ventilation in some severely ill or injured patients, and advanced airway interventions are then required. Controversy exists regarding the level of provider required to perform successful pre-hospital intubation. A previous meta-analysis reported pre-hospital intubation success rates of 0.849 for non-physicians versus 0.991 for physicians. The evidence base on the topic has expanded significantly in the last 10 years. This study systematically reviewed recent literature and presents comprehensive data on intubation success rates. Methods: A systematic search of MEDLINE and EMBASE was performed using PRISMA methodology to identify articles on pre-hospital tracheal intubation published between 2006 and 2016. Overall success rates were estimated using random effects meta-analysis. The relationship between intubation success rate and provider type was assessed in weighted linear regression analysis. Results: Of the 1838 identified studies, 38 met the study inclusion criteria. Intubation was performed by non-physicians in half of the studies and by physicians in the other half. The crude median (range) reported overall success rate was 0.969 (0.616–1.000). In random effects meta-analysis, the estimated overall intubation success rate was 0.953 (0.938–0.965). The crude median (range) reported intubation success rates for non-physicians were 0.917 (0.616–1.000) and, for physicians, were 0.988 (0.781–1.000) (p = 0.003). Discussion: The reported overall success rate of pre-hospital intubation has improved, yet there is still a significant difference between non-physician and physician providers. The finding that less-experienced personnel perform less well is not unexpected, but since there is considerable evidence that poorly performed intubation carries a significant risk of morbidity and mortality careful consideration should be given to the training and experience required to deliver this intervention safely.publishedVersio

    CDMSlite: A Search for Low-Mass WIMPs using Voltage-Assisted Calorimetric Ionization Detection in the SuperCDMS Experiment

    Get PDF
    SuperCDMS is an experiment designed to directly detect Weakly Interacting Massive Particles (WIMPs), a favored candidate for dark matter ubiquitous in the Universe. In this paper, we present WIMP-search results using a calorimetric technique we call CDMSlite, which relies on voltage- assisted Luke-Neganov amplification of the ionization energy deposited by particle interactions. The data were collected with a single 0.6 kg germanium detector running for 10 live days at the Soudan Underground Laboratory. A low energy threshold of 170 eVee (electron equivalent) was obtained, which allows us to constrain new WIMP-nucleon spin-independent parameter space for WIMP masses below 6 GeV/c2.Comment: 7 pages, 4 figure

    Improved WIMP-search reach of the CDMS II germanium data

    Get PDF
    CDMS II data from the five-tower runs at the Soudan Underground Laboratory were reprocessed with an improved charge-pulse fitting algorithm. Two new analysis techniques to reject surface-event backgrounds were applied to the 612 kg days germanium-detector weakly interacting massive particle (WIMP)-search exposure. An extended analysis was also completed by decreasing the 10 keV analysis threshold to ~5  keV, to increase sensitivity near a WIMP mass of 8  GeV/c[superscript 2]. After unblinding, there were zero candidate events above a deposited energy of 10 keV and six events in the lower-threshold analysis. This yielded minimum WIMP-nucleon spin-independent scattering cross-section limits of 1.8 × 10[superscript −44] and 1.18 × 10[superscript −41] at 90% confidence for 60 and 8.6  GeV/c[superscript 2] WIMPs, respectively. This improves the previous CDMS II result by a factor of 2.4 (2.7) for 60 (8.6)  GeV/c[superscript 2] WIMPs.National Science Foundation (U.S.)United States. Dept. of EnergyNatural Sciences and Engineering Research Council of CanadaSpain. Ministerio de Economia y Competitividad (MultiDark

    Demonstration of surface electron rejection with interleaved germanium detectors for dark matter searches

    Get PDF
    The SuperCDMS experiment in the Soudan Underground Laboratory searches for dark matter with a 9-kg array of cryogenic germanium detectors. Symmetric sensors on opposite sides measure both charge and phonons from each particle interaction, providing excellent discrimination between electron and nuclear recoils, and between surface and interior events. Surface event rejection capabilities were tested with two 210 Pb sources producing ∼130 beta decays/hr. In ∼800 live hours, no events leaked into the 8–115 keV signal region, giving upper limit leakage fraction 1.7 × 10−5 at 90% C.L., corresponding to < 0.6 surface event background in the future 200-kg SuperCDMS SNOLAB experiment

    Maximum Likelihood Analysis of Low Energy CDMS II Germanium Data

    Get PDF
    We report on the results of a search for a Weakly Interacting Massive Particle (WIMP) signal in low-energy data of the Cryogenic Dark Matter Search experiment using a maximum likelihood analysis. A background model is constructed using geant4 to simulate the surface-event background from Pb210 decay-chain events, while using independent calibration data to model the gamma background. Fitting this background model to the data results in no statistically significant WIMP component. In addition, we perform fits using an analytic ad hoc background model proposed by Collar and Fields, who claimed to find a large excess of signal-like events in our data. We confirm the strong preference for a signal hypothesis in their analysis under these assumptions, but excesses are observed in both single- and multiple-scatter events, which implies the signal is not caused by WIMPs, but rather reflects the inadequacy of their background model

    First Direct Limits on Lightly Ionizing Particles with Electric Charge Less than e/6

    Get PDF
    While the standard model of particle physics does not include free particles with fractional charge, experimental searches have not ruled out their existence. We report results from the Cryogenic Dark Matter Search (CDMS II) experiment that give the first direct-detection limits for cosmogenically produced relativistic particles with electric charge lower than e/6. A search for tracks in the six stacked detectors of each of two of the CDMS II towers finds no candidates, thereby excluding new parameter space for particles with electric charges between e/6 and e/200

    Dark matter effective field theory scattering in direct detection experiments

    Get PDF
    We examine the consequences of the effective field theory (EFT) of dark matter–nucleon scattering for current and proposed direct detection experiments. Exclusion limits on EFT coupling constants computed using the optimum interval method are presented for SuperCDMS Soudan, CDMS II, and LUX, and the necessity of combining results from multiple experiments in order to determine dark matter parameters is discussed. We demonstrate that spectral differences between the standard dark matter model and a general EFT interaction can produce a bias when calculating exclusion limits and when developing signal models for likelihood and machine learning techniques. We also discuss the implications of the EFT for the next-generation (G2) direct detection experiments and point out regions of complementarity in the EFT parameter space.National Science Foundation (U.S.)United States. Dept. of EnergyNatural Sciences and Engineering Research Council of CanadaSpain. Ministerio de Economia y Competitividad (MultiDark
    • …
    corecore