77 research outputs found

    Correction to: Comparison of cross-sectional area and fat infiltration of suboccipital muscles between normal dogs and dogs with atlantoaxial instability

    Get PDF
    BACKGROUND: Atlantoaxial instability (AAI) is primarily a congenital neurological disorder affecting young toy-breed dogs. So far, most studies have focused on bones and ligaments related to AAI, and there are no studies on the suboccipital muscles (SOMs) that occupy a large area from the occipital bone to C2 in dogs. This study evaluated the cross-sectional area (CSA) and fat infiltration of the SOMs using magnetic resonance imaging (MRI), specifically, T1-weighted images, in normal dogs (≤ 5 kg) and AAI dogs. The relationship between the severity of the neurological symptoms of AAI (group A and group B) and the values from MRI was also assessed. RESULTS: AAI dogs had significantly smaller CSA (P = 0.029) and greater fat infiltration (P = 0.044) of the SOMs compared to normal dogs. AAI dogs with mild neurological symptoms for a long period (group A) had greater fat infiltration than AAI dogs with severe neurological symptoms (group B) (P = 0.035). CONCLUSIONS: The muscle changes are most likely due to spinal cord compression resulting from instability; however, the possibility that chronic changes of the muscle may play an additional role in maintaining stability in this region cannot be excluded. This study provides fundamental quantitative information of the SOMs in normal and AAI dogs

    Chemically modulated graphene quantum dot for tuning the photoluminescence as novel sensory probe

    Get PDF
    A band gap tuning of environmental-friendly graphene quantum dot (GQD) becomes a keen interest for novel applications such as photoluminescence (PL) sensor. Here, for tuning the band gap of GQD, a hexafluorohydroxypropanyl benzene (HFHPB) group acted as a receptor of a chemical warfare agent was chemically attached on the GQD via the diazonium coupling reaction of HFHPB diazonium salt, providing new HFHPB-GQD material. With a help of the electron withdrawing HFHPB group, the energy band gap of the HFHPB-GQD was widened and its PL decay life time decreased. As designed, after addition of dimethyl methyl phosphonate (DMMP), the PL intensity of HFHPB-GQD sensor sharply increased up to approximately 200% through a hydrogen bond with DMMP. The fast response and short recovery time was proven by quartz crystal microbalance (QCM) analysis. This HFHPB-GQD sensor shows highly sensitive to DMMP in comparison with GQD sensor without HFHPB and graphene. In addition, the HFHPB-GQD sensor showed high selectivity only to the phosphonate functional group among many other analytes and also stable enough for real device applications. Thus, the tuning of the band gap of the photoluminescent GQDs may open up new promising strategies for the molecular detection of target substrates. © The Author(s) 20166511sciescopu

    Three-dimensional CT angiography of the canine hepatic vasculature

    Get PDF
    Eight Beagle dogs were anesthetized and were imaged using a single channel helical CT scanner. The contrast medium used in this study was iohexol (300 mg I/ml) and doses were 0.5 ml/kg for a cine scan, 3 ml/kg for an enhanced scan. The flow rate for contrast material administration was 2 ml/sec for all scans. This study was divided into three steps, with unenhanced, cine and enhanced scans. The enhanced scan was subdivided into the arterial phase and the venous phase. All of the enhanced scans were reconstructed in 1 mm intervals and the scans were interpreted by the use of reformatted images, a cross sectional histogram, maximum intensity projection and shaded surface display. For the cine scans, optimal times were a 9-sec delay time post IV injection in the arterial phase, and an 18-sec delay time post IV injection in the venous phase. A nine-sec delay time was acceptable for the imaging of the canine hepatic arteries by CT angiography. After completion of arterial phase scanning, venous structures of the liver were well visualized as seen on the venous phase

    Osteochondrodysplasia in three Scottish Fold cats

    Get PDF
    This report explains typical radiographic features of Scottish Fold osteochondrodysplasia. Three Scottish Fold cats suffering from lameness were referred to the Veterinary Medical Teaching Hospital, Seoul National University, Korea. Based on the breed predisposition, history, clinical signs, physical examination, and radiographic findings, Scottish Fold osteochondrodysplasia was confirmed in three cases. Radiographic changes mainly included exostosis and secondary arthritis around affected joint lesions, and defective conformation in the phalanges and caudal vertebrae. The oral chondroprotective agents such as glucosamine and chondroitin sulfate make the patients alleviate their pain without adverse effects

    Computed tomographic characteristics of acute thoracolumbar intervertebral disc disease in dogs

    Get PDF
    Forty canine patients with a presumptive diagnosis of the intervertebral disc herniation at the thoracolumbar region were imaged. A neurological examination was performed and all patients were classified under four grades by the examination. The degrees of attenuation of the herniated disc material were measured in Housefield units (HU) in each image. The ratio of the area to herniated disc material and the height to disc material were measured. The clinical grade was correlated with the area ratio of the herniated disc material to the spinal cord, but not correlated with the height ratio of that. In the patients with epidural hemorrhage at surgery, HUs of the herniated disc material was lower than those with no epidural hemorrhage at surgery. Non-contrast computed tomography scans of the spine can be useful in diagnosing acute intervertebral disc disease in chondrodystrophoid breeds, evaluating patient status and identifying concurrent epidural hemorrhage

    Computed tomographic evaluation of abdominal fat in minipigs

    Get PDF
    Computed tomography (CT) exams were conducted to determine the distribution of abdominal fat identified based on the CT number measured in Hounsfield Units (HU) and to measure the volume of the abdominal visceral and subcutaneous fat in minipigs. The relationship between the CT-based fat volumes of several vertebral levels and the entire abdomen and anthropometric data including the sagittal abdominal diameter and waist circumference were evaluated. Moreover, the total fat volumes at the T11, T13, L3, and L5 levels were compared with the total fat volume of the entire abdomen to define the landmark of abdominal fat distribution. Using a single-detector CT, six 6-month-old male minipigs were scanned under general anesthesia. Three radiologists then assessed the HU value of visceral and subcutaneous abdominal fat by drawing the region of interest manually at the T11, T13, L1, L3, and L5 levels. The CT number and abdominal fat determined in this way by the three radiologists was found to be correlated (intra-class coefficient = 0.9). The overall HU ranges for the visceral and subcutaneous fat depots were -147.47 to -83.46 and -131.62 to -90.97, respectively. The total fat volume of the entire abdomen was highly correlated with the volume of abdominal fat at the T13 level (r = 0.97, p < 0.0001). These findings demonstrate that the volume of abdominal adipose tissue measured at the T13 level using CT is a strong and reliable predictor of total abdominal adipose volume

    Outbreak and control of haemorrhagic pneumonia due to Streptococcus equi subspecies zooepidemicus in dogs

    Get PDF
    This work was supported by the Brain Korea 21 Program for Veterinary Science and the Korea Research Foundation (KRF- 2004-005-E00077)

    Assessment of glomerular filtration rate with dynamic computed tomography in normal Beagle dogs

    Get PDF
    The objective of our study was to determine individual and global glomerular filtration rates (GFRs) using dynamic renal computed tomography (CT) in Beagle dogs. Twenty-four healthy Beagle dogs were included in the experiment. Anesthesia was induced in all dogs by using propofol and isoflurane prior to CT examination. A single slice of the kidney was sequentially scanned after a bolus intravenous injection of contrast material (iohexol, 1 mL/kg, 300 mgI/mL). Time attenuation curves were created and contrast clearance per unit volume was calculated using a Patlak plot analysis. The CT-GFR was then determined based on the conversion of contrast clearance per unit volume to contrast clearance per body weight. At the renal hilum, CT-GFR values per unit renal volume (mL/min/mL) of the right and left kidneys were 0.69 ± 0.04 and 0.57 ± 0.05, respectively. No significant differences were found between the weight-adjusted CT-GFRs in either kidney at the same renal hilum (p = 0.747). The average global GFR was 4.21 ± 0.25 mL/min/kg and the whole kidney GFR was 33.43 ± 9.20 mL/min. CT-GFR techniques could be a practical way to separately measure GFR in each kidney for clinical and research purposes

    Lung lobe torsion in a Yorkshire terrier

    No full text

    How Customers Perceive Virtual Mirror Technology in the 4th Industrial Revolution Environment

    No full text
    Purpose: The purpose of this study is to explore how customers perceive virtual mirror technology in the 4th industrial revolution environment. In particular, this study investigated how virtual mirror technology affects customer satisfaction and intention to use that are rarely examined in previous studies. Research questions include how proposed variables including sensory stimulation, enjoyment, product quality, telepresence, interactivity, and immersion affect satisfaction and intention to use and how satisfaction affects intention to use. Research design, data and methodology: This study conducted an online survey and applied factor and regression analyses to test hypotheses. Results: The results of this study found that effects of sensory stimulation, telepresence, and immersion on satisfaction were significant, while effects of enjoyment, product quality, and immersion on intention to use were significant. Therefore, variables affecting satisfaction and intention to use were different, while effects of immersion were significant both on satisfaction and intention to use. Conclusions: This study concluded that the role of virtual mirror technology helps customers determine product quality and increase satisfaction level, while it also helps customers enjoy shopping and increase intent to use the service. The results of this study provide how to foster better relationship with customers by applying advanced technologies.2
    corecore