1,392 research outputs found

    A novel space-vector algorithm for multilevel converters based on geometrical considerations using a new sequence control technique

    Get PDF
    his paper presents a fast and simple space vector modulation algorithm for voltage source multilevel converters for calculating the switching times and the space vectors using simple geometrical considerations. This method provides the nearest switching vectors sequence to the reference vector and calculates the on-state durations of the respective switching state vectors without involving trigonometric functions, look-up tables or coordinate system transformations which increase the computational load corresponding to the modulation of a multilevel converter. The low computational cost of the proposed method is always the same and it is independent of the number of levels of the converter. In addition, a new switching sequence control technique is presented for reducing the ripple of the DC-link voltage approximately in 66%

    Dental implants placed on bone subjected to vertical alveolar distraction show the same performance as those placed on primitive bone

    Get PDF
    Introduction: Vertical osteogenic alveolar distraction (VOAD) allows for the augmentation of the alveolar ridge for the placement of dental implants in atrophic alveolar ridges. The goal of this paper is to assess long-term peri- implant bone resorption in implants placed on bones subjected to VOAD, comparing it with a group of patients who had implants placed directly on the alveolar bone without previous bone regeneration. Material and Methods: We conducted a follow-up study on 32 patients who were divided into two groups: The Distraction Group (14 patients), and the Distraction-Free Group (18 patients), who received a total of 100 implants. Peri-implant bone loss was measured by means of panoramic X-rays, at the time of loading and one year later, and in 35 implants of each group after 3 years of functional loading. Results: The peri-implant bone resorption (PBR) average observed in the Distraction Group at the time of prosthetic placement is higher (0.50±0.09 mm) than in the Distraction-Free Group (0.25±0.06 mm), showing statistically significant results (p=0.047). PBR levels 1 year after loading were the same for both groups (0.66 mm). At 3 years, they were higher in the Distraction Group (1.03 ± 0.22 mm vs. 0.68 ± 0.08 mm)

    Kinetic theory of a confined quasi-one-dimensional gas of hard disks

    Get PDF
    A dilute gas of hard disks confined between two straight parallel lines is considered. The distance between the two boundaries is between one and two particle diameters, so that the system is quasi-one-dimensional. A Boltzmann-like kinetic equation, that takes into account the limitation in the possible scattering angles, is derived. It is shown that the equation verifies an -theorem implying a monotonic approach to equilibrium. The implications of this result are discussed, and the equilibrium properties are derived. Closed equations describing how the kinetic energy is transferred between the degrees of freedom parallel and perpendicular to the boundaries are derived for states that are homogeneous along the direction of the boundaries. The theoretical predictions agree with results obtained by means of Molecular Dynamics simulations.Consejería de Economía, Conocimiento, Empresas y Universidad de la Junta de Andalucía US-1380729 (partially financed by FEDER 2014-2020 funds

    Llano Alto (Béjar-Salamanca) : aula activa de la naturaleza

    Get PDF
    Copia digital : Junta de Castilla y León. Consejería de Cultura y Turismo, 201

    Generalized analytical approach of the calculation of the harmonic effects of single phase multilevel PWM inverters

    Get PDF
    This paper introduces a generalized analytical approach for calculating the total harmonic distortion THD and its weighted value WTHD for multilevel PWM inverters. The calculation considers one single phase and it can apply to any number of levels of the inverter in general. Although the analysis is based on the assumption of a high number of pulses, the developed equations can also be applied for lower frequency ratios fs/f1. The analytical formulas require the characteristic parameters of the PWM only, which are the modulation factor m, the switching frequency fs, the fundamental frequency f1, the effective inductance L and the DC link voltage inverters with a number of levels N are considered. It must be noticed that some differences appear between the case of N odd and N even. Several parametric curves arc calculated to define the specifications of an inverter with N levels in order to fulfill the harmonic voltage recommendations trying to reduce the output signal filtering

    Three-dimensional space vector modulation in abc coordinates for four-leg voltage source converters

    Get PDF
    Four-leg inverters have been selected as one of the preferred power converter topologies for applications that require a precise control of neutral current, like active filters. The main advantage of this topology lies in an extended range for the zero sequence voltages and currents. However, the addition of a fourth leg extends the space vectors from two to three dimensions, making the selection of the modulation vectors more complex. Most of the algorithms that deal with this problem require an /spl alpha//spl beta//spl gamma/ transformation. This paper presents a new space vector modulation algorithm using abc coordinates (the phase voltages) avoiding the /spl alpha//spl beta//spl gamma/ transformation. Thanks to the use of abc coordinates, the algorithm is much simpler and more intuitive than in /spl alpha//spl beta//spl gamma/ representation, drastically reducing the complexity of modulation algorithm and the computational load associated to it

    Tuberculosis-Related Deaths within a Well-Functioning DOTS Control Program

    Get PDF
    To describe the molecular epidemiology of tuberculosis (TB)-related deaths in a well-managed program in a low-HIV area, we analyzed data from a cohort of 454 pulmonary TB patients recruited between March 1995 and October 2000 in southern Mexico. Patients who were sputum acid-fast bacillus smear positive underwent clinical and mycobacteriologic evaluation (isolation, identification, drug-susceptibility testing, and IS6110-based genotyping and spoligotyping) and received treatment from the local directly observed treatment strategy (DOTS) program. After an average of 2.3 years of follow-up, death was higher for clustered cases (28.6 vs. 7%, p=0.01). Cox analysis revealed that TB-related mortality hazard ratios included treatment default (8.9), multidrug resistance (5.7), recently transmitted TB (4.1), weight loss (3.9), and having less than 6 years of formal education (2). In this community, TB is associated with high mortality rates

    Detection of Executive Performance Profiles Using the ENFEN Battery in Children Diagnosed With Attention-Deficit Hyperactivity Disorder

    Get PDF
    Attention-deficit hyperactivity disorder (ADHD) is one of the most common neurodevelopmental disorders in children and adolescents. People who have this disorder are characterized by presenting difficulties in the processes of sustained attention, being very active, and having poor control of their impulses. Despite the high prevalence of this disorder and the existence of various tests used for its diagnosis, few data are available regarding the usefulness and diagnostic validity of these tools. Given the difficulties that these subjects present in executive functions, the aim of this study was to evaluate whether the Neuropsychological Assessment of Executive Functions battery for Children (ENFEN, for its acronym in Spanish, Portellano et al., 2009) allows to establish specific profiles of executive performance for people with attention-deficit hyperactivity disorder (ADHD). The sample was made up of 197 participants of both sexes, aged between 6 and 12 years age (134 with a clinical diagnosis and 63 without pathology). A nonexperimental design was followed, using a comparative descriptive study method. The results indicated that the scales of phonological fluency, color path, rings, and interference are the most associated with the diagnosis of ADHD, providing data on inhibition, mental flexibility, sustained and selective attention, planning, verbal fluency, and working memory, among others. The practical implication of these results is in line with providing support in the clinical diagnosis that is carried out in children’s mental health units. In addition, the ENFEN tool can be valued as a suitable psychometric instrument in the psychoeducational field, helping professionals in a school environment to be more aware of the areas of cognitive development in which a student diagnosed with ADHD will have more difficulties and, in doing so, providing more adjusted and effective psychopedagogical measures when it comes to supporting students in their adaptation to the school environment

    Plasma ACE2 species are differentially altered in COVID-19 patients

    Get PDF
    Studies are needed to identify useful biomarkers to assess the severity and prognosis of COVID-19 disease, caused by severe acute respiratory syndrome coronavirus (SARS-CoV-2) virus. Here, we examine the levels of various plasma species of the SARS-CoV-2 host receptor, the angiotensin-converting enzyme 2 (ACE2), in patients at different phases of the infection. Human plasma ACE2 species were characterized by immunoprecipitation and western blotting employing antibodies against the ectodomain and the C-terminal domain, using a recombinant human ACE2 protein as control. In addition, changes in the cleaved and full-length ACE2 species were also examined in serum samples derived from humanized K18-hACE2 mice challenged with a lethal dose of SARS-CoV-2. ACE2 immunoreactivity was present in human plasma as several molecular mass species that probably comprise truncated (70 and 75 kDa) and full-length forms (95, 100, 130, and 170 kDa). COVID-19 patients in the acute phase of infection (n = 46) had significantly decreased levels of ACE2 full-length species, while a truncated 70-kDa form was marginally higher compared with non-disease controls (n = 26). Levels of ACE2 full-length species were in the normal range in patients after a recovery period with an interval of 58-70 days (n = 29), while the 70-kDa species decreased. Levels of the truncated ACE2 species served to discriminate between individuals infected by SARS-CoV-2 and those infected with influenza A virus (n = 17). In conclusion, specific plasma ACE2 species are altered in patients with COVID-19 and these changes normalize during the recovery phase. Alterations in ACE2 species following SARS-CoV-2 infection warrant further investigation regarding their potential usefulness as biomarkers for the disease process and to asses efficacy during vaccination
    corecore