    Reduction of the model noise in non-linear reconstruction via an efficient calculation of the incident field: application to a 434 MHz Scanner

    Get PDF
    Microwave tomography has been drastically boosted by the development of efficient reconstruction algorithms based on an iterative solution of the corresponding non-linear inverse problem. The accuracy of the electric field radiated by the antennas of a microwave scanner, inside the target area, has been shown to play a significant role on the overall image quality. Taking into account the antenna environment is of prime importance, especially when operating at low frequency. For instance, the wall of a 60 cm diameter whole-body microwave scanner cannot be neglected at 434 MHz, even when using the immersion technique consisting of putting the target in water. Indeed, at such a frequency, the attenuation introduced by water is not sufficient to avoid multiple reflections on the scanner boundary walls. Consequently, the method of calculating the incident field constitutes a key factor in iteratively solving non-linear inverse problems. The selected technique must accommodate high accuracy while maintaining acceptable calculation complexity. In this paper, three distinct techniques are analysed. They are based on the use of i) free-space and ii) non free-space Green's function, and iii) a FDTD approach. All these techniques have been firstly investigated for their 2D version, being used in 2D reconstruction algorithms. However, the scattered field data are collected in a 3D scanner. For assessing the validity of the previous 2D techniques, their results have been compared to both experimentally and 3D-FDTD results.Peer ReviewedPostprint (published version

    Microwave imaging techniques for biomedical applications

    Get PDF
    Microwaves have been considered for medical applications involving the detection of organ movements and changes in tissue water content. More particularly cardiopulmonary interrogation via microwaves has resulted in various sensors monitoring ventricular volume change or movement, arterial wall motion, respiratory movements, pulmonary oedema, etc. In all these applications, microwave sensors perform local measurements and need to be displaced for obtaining an image reproducing the spatial variations of a given quantity. Recently, advances in the area of inverse scattering theory and microwave technology have made possible the development of microwave imaging and tomographic instruments. This paper provides a review of such equipment developed at Suplec and UPC Barcelona, within the frame of successive French-Spanish PICASSO cooperation programs. It reports the most significant results and gives some perspectives for future developments. Firstly, a brief historical survey is given. Then, both technological and numerical aspects are considered. The results of preliminary pre-clinical assessments and in-lab experiments allow to illustrate the capabilities of the existing equipment, as well as its difficulty in dealing with clinical situations. Finally, some remarks on the expected development of microwave imaging techniques for biomedical applications are given.Peer ReviewedPostprint (published version

    Quantitative images of large biological bodies in microwave tomography by using numerical and real data

    Get PDF
    A new inverse microwave imaging algorithm is presented which has the ability to obtain quantitative dielectric maps of large biological bodies. By using a priori information, obtained with a first order algorithm, the final image is obtained by solving the direct problem and an ill-conditioned system of equations into an iterative procedure. The algorithm has been successfully tested with real data from an experimental scanner.Peer Reviewe

    Database of "in vivo" measurements for quantitative microwave imaging and reconstruction algorithms available

    Get PDF
    Reconstruction algorithms and equipment have been developed for microwave imaging, with emphasis on noninvasive control of deep hyperthermia treatments. Tomographic reconstruction algorithms have also been developed for qualitative spectral and quantitative spatial iterations. The data can be accessed from the e-mail address ftp voltor.upc.es.Peer Reviewe

    Convergence and stability assessment of Newton-Kantorovich reconstrutin algorithms for microwve tomography

    Get PDF
    For newly developed iterative Newton-Kantorovitch reconstruction techniques, the quality of the final image depends on both experimental and model noise. Experimental noise is inherent to any experimental acquisition scheme, while model noise refers to the accuracy of the numerical model, used in the reconstruction process, to reproduce the experimental setup. This paper provides a systematic assessment of the major sources of experimental and model noise on the quality of the final image. This assessment is conducted from experimental data obtained with a microwave circular scanner operating at 2.33 GHz. Targets to be imaged include realistic biological structures, such as a human forearm, as well as calibrated samples for the sake of accuracy evaluation. The results provide a quantitative estimation of the effect of experimental factors, such as temperature of the immersion medium, frequency, signal-to-noise ratio, and various numerical parameters.Peer Reviewe

    Design and Experimental Assessment of a 2D Microwave Imaging System for Brain Stroke Monitoring

    Get PDF
    The aim of this paper is to present and experimentally verify the first prototype of a microwave imaging system specifically designed and realized for the continuous monitoring of patients affected by brain stroke, immediately after its onset and diagnosis. The device is a 2D version of the 3D system, currently under construction, and consists of an array of 12 printed monopole antennas connected to a two-port vector network analyzer through a switching matrix so that each antenna can act as a transmitter or receiver, thereby allowing the acquisition of the entire multistatic multiview scattering matrix required for the imaging. The system has been experimentally tested on 2D phantoms with electric properties mimicking the brain. The presence and the evolution of the stroke have been reproduced by filling a proper cavity in the phantom with a liquid having the electric properties of blood. A differential approach has been adopted by acquiring the scattering matrix before and after the filling of the blood cavity. The so achieved differential dataset has been processed by means of a linear imaging algorithm in order to reconstruct the stroke location and dimension. Moreover, the effect of pre- and postprocessing operations on the measured data is investigated. A good agreement has been obtained between the reconstructions and the actual scenario. As a final remark, it is worth noting that the entire data acquisition and processing are sufficiently fast to allow a real-time monitoring

    Planar and cylindrical active microwave temperature imaging: numerical simulations

    Get PDF
    A comparative study at 2.45 GHz concerning both measurement and reconstruction parameters for planar and cylindrical configurations is presented. For the sake of comparison, a numerical model consisting of two nonconcentric cylinders is considered and reconstructed using both geometries from simulated experimental data. The scattered fields and reconstructed images permit extraction of very useful information about dynamic range, sensitivity, resolution, and quantitative image accuracy for the choice of the configuration in a particular application. Both geometries can measure forward and backward scattered fields. The backscattering measurement improves the image resolution and reconstruction in lossy mediums, but, on the other hand, has several dynamic range difficulties. This tradeoff between forward only and forward-backward field measurement is analyzed. As differential temperature imaging is a weakly scattering problem, Born approximation algorithms can be used. The simplicity of Born reconstruction algorithms and the use of FFT make them very attractive for real-time biomedical imaging systems.Peer Reviewe

    Development of an Anthropomorphic Phantom of the Axillary Region for Microwave Imaging Assessment

    Get PDF
    We produced an anatomically and dielectrically realistic phantom of the axillary region to enable the experimental assessment of Axillary Lymph Node (ALN) imaging using microwave imaging technology. We segmented a thoracic Computed Tomography (CT) scan and created a computer-aided designed file containing the anatomical configuration of the axillary region. The phantom comprises five 3D-printed parts representing the main tissues of interest of the axillary region for the purpose of microwave imaging: fat, muscle, bone, ALNs, and lung. The phantom allows the experimental assessment of multiple anatomical configurations, by including ALNs of different size, shape, and number in several locations. Except for the bone mimicking organ, which is made of solid conductive polymer, we 3D-printed cavities to represent the fat, muscle, ALN, and lung and filled them with appropriate tissue-mimicking liquids. Existing studies about complex permittivity of ALNs have reported limitations. To address these, we measured the complex permittivity of both human and animal lymph nodes using the standard open-ended coaxial-probe technique, over the 0.5 GHz-8.5 GHz frequency band, thus extending current knowledge on dielectric properties of ALNs. Lastly, we numerically evaluated the effect of the polymer which constitutes the cavities of the phantom and compared it to the realistic axillary region. The results showed a maximum difference of 7 dB at 4 GHz in the electric field magnitude coupled to the tissues and a maximum of 10 dB difference in the ALN response. Our results showed that the phantom is a good representation of the axillary region and a viable tool for pre-clinical assessment of microwave imaging technology.info:eu-repo/semantics/publishedVersio

    Planar and cylindrical active microwave temperature imaging: numerical simulations

    Get PDF
    A comparative study at 2.45 GHz concerning both measurement and reconstruction parameters for planar and cylindrical configurations is presented. For the sake of comparison, a numerical model consisting of two nonconcentric cylinders is considered and reconstructed using both geometries from simulated experimental data. The scattered fields and reconstructed images permit extraction of very useful information about dynamic range, sensitivity, resolution, and quantitative image accuracy for the choice of the configuration in a particular application. Both geometries can measure forward and backward scattered fields. The backscattering measurement improves the image resolution and reconstruction in lossy mediums, but, on the other hand, has several dynamic range difficulties. This tradeoff between forward only and forward-backward field measurement is analyzed. As differential temperature imaging is a weakly scattering problem, Born approximation algorithms can be used. The simplicity of Born reconstruction algorithms and the use of FFT make them very attractive for real-time biomedical imaging systemsPeer ReviewedPostprint (published version