62 research outputs found
Recommended from our members
Biocompatible magnetic fluids of co-doped iron oxide nanoparticles with tunable magnetic properties
Magnetite (Fe3O4) particles with a diameter around 10 nm have a very low coercivity (Hc) and relative remnant magnetization (Mr/Ms), which is unfavorable for magnetic fluid hyperthermia. In contrast, cobalt ferrite (CoFe2O4) particles of the same size have a very high Hc and Mr/Ms, which is magnetically too hard to obtain suitable specific heating power (SHP) in hyperthermia. For the optimization of the magnetic properties, the Fe2+ ions of magnetite were substituted by Co2+ step by step, which results in a Co doped iron oxide inverse spinel with an adjustable Fe2+ substitution degree in the full range of pure iron oxide up to pure cobalt ferrite. The obtained magnetic nanoparticles were characterized regarding their structural and magnetic properties as well as their cell toxicity. The pure iron oxide particles showed an average size of 8 nm, which increased up to 12 nm for the cobalt ferrite. For ferrofluids containing the prepared particles, only a limited dependence of Hc and Mr/Ms on the Co content in the particles was found, which confirms a stable dispersion of the particles within the ferrofluid. For dry particles, a strong correlation between the Co content and the resulting Hc and Mr/Ms was detected. For small substitution degrees, only a slight increase in Hc was found for the increasing Co content, whereas for a substitution of more than 10% of the Fe atoms by Co, a strong linear increase in Hc and Mr/Ms was obtained. Mössbauer spectroscopy revealed predominantly Fe3+ in all samples, while also verifying an ordered magnetic structure with a low to moderate surface spin canting. Relative spectral areas of Mössbauer subspectra indicated a mainly random distribution of Co2+ ions rather than the more pronounced octahedral site-preference of bulk CoFe2O4. Cell vitality studies confirmed no increased toxicity of the Co-doped iron oxide nanoparticles compared to the pure iron oxide ones. Magnetic heating performance was confirmed to be a function of coercivity as well. The here presented non-toxic magnetic nanoparticle system enables the tuning of the magnetic properties of the particles without a remarkable change in particles size. The found heating performance is suitable for magnetic hyperthermia application. © 2020 by the authors. Licensee MDPI, Basel, Switzerland
Recommended from our members
Biocompatible magnetic fluids of Co-doped iron oxide nanoparticles with tunable magnetic properties
Magnetite (Fe3O4) particles with a diameter around 10 nm have a very low coercivity (Hc) and relative remnant magnetization (Mr/Ms), which is unfavorable for magnetic fluid hyperthermia. In contrast, cobalt ferrite (CoFe2O4) particles of the same size have a very high Hc and Mr/Ms, which is magnetically too hard to obtain suitable specific heating power (SHP) in hyperthermia. For the optimization of the magnetic properties, the Fe2+ ions of magnetite were substituted by Co2+ step by step, which results in a Co doped iron oxide inverse spinel with an adjustable Fe2+ substitution degree in the full range of pure iron oxide up to pure cobalt ferrite. The obtained magnetic nanoparticles were characterized regarding their structural and magnetic properties as well as their cell toxicity. The pure iron oxide particles showed an average size of 8 nm, which increased up to 12 nm for the cobalt ferrite. For ferrofluids containing the prepared particles, only a limited dependence of Hc and Mr/Ms on the Co content in the particles was found, which confirms a stable dispersion of the particles within the ferrofluid. For dry particles, a strong correlation between the Co content and the resulting Hc and Mr/Ms was detected. For small substitution degrees, only a slight increase in Hc was found for the increasing Co content, whereas for a substitution of more than 10% of the Fe atoms by Co, a strong linear increase in Hc and Mr/Ms was obtained. Mössbauer spectroscopy revealed predominantly Fe3+ in all samples, while also verifying an ordered magnetic structure with a low to moderate surface spin canting. Relative spectral areas of Mössbauer subspectra indicated a mainly random distribution of Co2+ ions rather than the more pronounced octahedral site-preference of bulk CoFe2O4. Cell vitality studies confirmed no increased toxicity of the Co-doped iron oxide nanoparticles compared to the pure iron oxide ones. Magnetic heating performance was confirmed to be a function of coercivity as well. The here presented non-toxic magnetic nanoparticle system enables the tuning of the magnetic properties of the particles without a remarkable change in particles size. The found heating performance is suitable for magnetic hyperthermia application
XMCD studies of thin Co films on BaTiO
Different layer thicknesses of Cobalt ranging from 2.6 {\AA} (1.5 ML) up to
55 {\AA} (30.5 ML) deposited on ferroelectric BaTiO have been studied
regarding their magnetic behavior. The layers have been characterized using
XMCD spectroscopy at remanent magnetization. After careful data analysis the
magnetic moments of the Cobalt could be determined using the sum rule
formalism. There is a sudden and abrupt onset in magnetism starting at
thicknesses of 9 {\AA} (5 ML) of Cobalt for measurements at 120 K and of 10
{\AA} (5.5 ML) if measured at room temperature. Initial island growth and
subsequent coalescence of Co on BaTiO is suggested to explain the sudden
onset. In that context, no magnetically dead layers are observed.Comment: 9 pages, 5 figures, submitted to J. Phys. Condens. Matte
Recommended from our members
Influence of Sterilization and Preservation Procedures on the Integrity of Serum Protein-Coated Magnetic Nanoparticles
Protein-coated magnetic nanoparticles are promising candidates for various medical applications. Prior to their application into a biological system, one has to guarantee that the particle dispersions are free from pathogens or any other microbiologic contamination. Furthermore, to find entrance into clinical routine, the nanoparticle dispersions have to be storable for several months. In this study, we tested several procedures for sterilization and preservation of nanoparticle containing liquids on their influence on the integrity of the protein coating on the surface of these particles. For this, samples were treated by freezing, autoclaving, lyophilization, and ultraviolet (UV) irradiation, and characterized by means of dynamic light scattering, determination of surface potential, and gel electrophoresis afterwards. We found that the UV sterilization followed by lyophilization under the addition of polyethylene glycol are the most promising procedures for the preparation of sterilized long-term durable protein-coated magnetic nanoparticles. Ongoing work is focused on the optimization of used protocols for UV sterilization and lyophilization for further improvement of the storage time
Classical-quantum correspondence in atomic ionization by midinfrared pulses: Multiple peak and interference structures
Atomic ionization by strong and ultrashort laser pulses with frequencies in the midinfrared spectral region have revealed novel features such as the low-energy structures. We have performed fully three-dimensional quantum dynamical as well as classical trajectory Monte Carlo simulations for pulses with wavelengths from λ=2000 to 6000 nm. Furthermore, we apply distorted-wave quantum approximations. This allows to explore the quantum-classical correspondence as well as the (non) perturbative character of the ionization dynamics driven by long-wavelength pulses. We observe surprisingly rich structures in the differential energy and angular momentum distribution which sensitively depend on λ, the pulse duration Ïp, and the carrier-envelope phase ÏCEP
Magnetic switching of nanoscale antidot lattices
We investigate the rich magnetic switching properties of nanoscale antidot lattices in the 200 nm regime. In-plane magnetized Fe, Co, and Permalloy (Py) as well as out-of-plane magnetized GdFe antidot films are prepared by a modified nanosphere lithography allowing for non-close packed voids in a magnetic film. We present a magnetometry protocol based on magneto-optical Kerr microscopy elucidating the switching modes using first-order reversal curves. The combination of various magnetometry and magnetic microscopy techniques as well as micromagnetic simulations delivers a thorough understanding of the switching modes. While part of the investigations has been published before, we summarize these results and add significant new insights in the magnetism of exchange-coupled antidot lattices.Web of Science775073
Influence of sterilization and preservation procedures on the integrity of serum protein-coated magnetic nanoparticles
Protein-coated magnetic nanoparticles are promising candidates for various medical applications. Prior to their application into a biological system, one has to guarantee that the particle dispersions are free from pathogens or any other microbiologic contamination. Furthermore, to find entrance into clinical routine, the nanoparticle dispersions have to be storable for several months. In this study, we tested several procedures for sterilization and preservation of nanoparticle containing liquids on their influence on the integrity of the protein coating on the surface of these particles. For this, samples were treated by freezing, autoclaving, lyophilization, and ultraviolet (UV) irradiation, and characterized by means of dynamic light scattering, determination of surface potential, and gel electrophoresis afterwards. We found that the UV sterilization followed by lyophilization under the addition of polyethylene glycol are the most promising procedures for the preparation of sterilized long-term durable protein-coated magnetic nanoparticles. Ongoing work is focused on the optimization of used protocols for UV sterilization and lyophilization for further improvement of the storage time
X-Ray Microscopy of Spin Wave Focusing using a Fresnel Zone Plate
Magnonics, i.e. the artificial manipulation of spin waves, is a flourishing
field of research with many potential uses in data processing within reach.
Apart from the technological applications the possibility to directly influence
and observe these types of waves is of great interest for fundamental research.
Guidance and steering of spin waves has been previously shown and lateral spin
wave confinement has been achieved. However, true spin wave focusing with both
lateral confinement and increase in amplitude has not been shown before. Here,
we show for the first time spin wave focusing by realizing a Fresnel zone plate
type lens. Using x-ray microscopy we are able to directly image the propagation
of spin waves into the nanometer sized focal spot. Furthermore, we observe that
the focal spot can be freely moved in a large area by small variations of the
bias field. Thus, this type of lens provides a steerable intense nanometer
sized spin wave source. Potentially, this could be used to selectively
illuminate magnonic devices like nano oscillators with a steerable spin wave
beam
- âŠ