2,701 research outputs found

    Towards Clustering of Mobile and Smartwatch Accelerometer Data for Physical Activity Recognition

    Get PDF
    Mobile and wearable devices now have a greater capability of sensing human activity ubiquitously and unobtrusively through advancements in miniaturization and sensing abilities. However, outstanding issues remain around the energy restrictions of these devices when processing large sets of data. This paper presents our approach that uses feature selection to refine the clustering of accelerometer data to detect physical activity. This also has a positive effect on the computational burden that is associated with processing large sets of data, as energy efficiency and resource use is decreased because less data is processed by the clustering algorithms. Raw accelerometer data, obtained from smartphones and smartwatches, have been preprocessed to extract both time and frequency domain features. Principle component analysis feature selection (PCAFS) and correlation feature selection (CFS) have been used to remove redundant features. The reduced feature sets have then been evaluated against three widely used clustering algorithms, including hierarchical clustering analysis (HCA), k-means, and density-based spatial clustering of applications with noise (DBSCAN). Using the reduced feature sets resulted in improved separability, reduced uncertainty, and improved efficiency compared with the baseline, which utilized all features. Overall, the CFS approach in conjunction with HCA produced higher Dunn Index results of 9.7001 for the phone and 5.1438 for the watch features, which is an improvement over the baseline. The results of this comparative study of feature selection and clustering, with the specific algorithms used, has not been performed previously and provides an optimistic and usable approach to recognize activities using either a smartphone or smartwatch

    Measurement of gut permeability using fluorescent tracer agent technology

    Get PDF
    Abstract The healthy gut restricts macromolecular and bacterial movement across tight junctions, while increased intestinal permeability accompanies many intestinal disorders. Dual sugar absorption tests, which measure intestinal permeability in humans, present challenges. Therefore, we asked if enterally administered fluorescent tracers could ascertain mucosal integrity, because transcutaneous measurement of differentially absorbed molecules could enable specimen-free evaluation of permeability. We induced small bowel injury in rats using high- (15 mg/kg), intermediate- (10 mg/kg), and low- (5 mg/kg) dose indomethacin. Then, we compared urinary ratios of enterally administered fluorescent tracers MB-402 and MB-301 to urinary ratios of sugar tracers lactulose and rhamnose. We also tested the ability of transcutaneous sensors to measure the ratios of absorbed fluorophores. Urinary fluorophore and sugar ratios reflect gut injury in an indomethacin dose dependent manner. The fluorophores generated smooth curvilinear ratio trajectories with wide dynamic ranges. The more chaotic sugar ratios had narrower dynamic ranges. Fluorophore ratios measured through the skin distinguished indomethacin-challenged from same day control rats. Enterally administered fluorophores can identify intestinal injury in a rat model. Fluorophore ratios are measureable through the skin, obviating drawbacks of dual sugar absorption tests. Pending validation, this technology should be considered for human use

    Targeting the differential addiction to anti-apoptotic BCL-2 family for cancer therapy

    Get PDF
    AbstractBCL-2 family proteins are central regulators of mitochondrial apoptosis and validated anti-cancer targets. Using small cell lung cancer (SCLC) as a model, we demonstrated the presence of differential addiction of cancer cells to anti-apoptotic BCL-2, BCL-XL or MCL-1, which correlated with the respective protein expression ratio. ABT-263 (navitoclax), a BCL-2/BCL-XL inhibitor, prevented BCL-XL from sequestering activator BH3-only molecules (BH3s) and BAX but not BAK. Consequently, ABT-263 failed to kill BCL-XL-addicted cells with low activator BH3s and BCL-XL overabundance conferred resistance to ABT-263. High-throughput screening identified anthracyclines including doxorubicin and CDK9 inhibitors including dinaciclib that synergized with ABT-263 through downregulation of MCL-1. As doxorubicin and dinaciclib also reduced BCL-XL, the combinations of BCL-2 inhibitor ABT-199 (venetoclax) with doxorubicin or dinaciclib provided effective therapeutic strategies for SCLC. Altogether, our study highlights the need for mechanism-guided targeting of anti-apoptotic BCL-2 proteins to effectively activate the mitochondrial cell death programme to kill cancer cells.</jats:p

    DAWN Mission Bus and Waveguide Venting Analysis Review

    Get PDF
    A concern was raised regarding the time after launch when the DAWN Mission Communications Subsystem, which contains a 100 Watt X-Band Traveling Wave Tube Amplifier (TWTA) with a high voltage ((approximately 7 Kilo Volt (KV)) Electronic Power Converter (EPC), will be powered on for the first post-launch downlink. This activation is planned to be approximately one hour after launch. Orbital Sciences (the DAWN Mission spacecraft contractor) typically requires a 24-hour wait period prior to high voltage initiation for Earth-orbiting Science and GEO spacecraft. The concern relates to the issue of corona and/or radio frequency (RF) breakdown of the TWTA ((high voltage direct current (DC) and RF)), and of the microwave components (high voltage RF) in the presence of partial atmospheric pressures or outgassing constituents. In particular, generally the diplexer and circulator are susceptible to RF breakdown in the corona region due to the presence of small physical gaps ((~ 2.5 millimeter (mm)) between conductors that carry an RF voltage. The NESC concurred the DAWN Mission communication system is safe for activation

    Using ordinal logistic regression to evaluate the performance of laser-Doppler predictions of burn-healing time

    Get PDF
    Background Laser-Doppler imaging (LDI) of cutaneous blood flow is beginning to be used by burn surgeons to predict the healing time of burn wounds; predicted healing time is used to determine wound treatment as either dressings or surgery. In this paper, we do a statistical analysis of the performance of the technique. Methods We used data from a study carried out by five burn centers: LDI was done once between days 2 to 5 post burn, and healing was assessed at both 14 days and 21 days post burn. Random-effects ordinal logistic regression and other models such as the continuation ratio model were used to model healing-time as a function of the LDI data, and of demographic and wound history variables. Statistical methods were also used to study the false-color palette, which enables the laser-Doppler imager to be used by clinicians as a decision-support tool. Results Overall performance is that diagnoses are over 90% correct. Related questions addressed were what was the best blood flow summary statistic and whether, given the blood flow measurements, demographic and observational variables had any additional predictive power (age, sex, race, % total body surface area burned (%TBSA), site and cause of burn, day of LDI scan, burn center). It was found that mean laser-Doppler flux over a wound area was the best statistic, and that, given the same mean flux, women recover slightly more slowly than men. Further, the likely degradation in predictive performance on moving to a patient group with larger %TBSA than those in the data sample was studied, and shown to be small. Conclusion Modeling healing time is a complex statistical problem, with random effects due to multiple burn areas per individual, and censoring caused by patients missing hospital visits and undergoing surgery. This analysis applies state-of-the art statistical methods such as the bootstrap and permutation tests to a medical problem of topical interest. New medical findings are that age and %TBSA are not important predictors of healing time when the LDI results are known, whereas gender does influence recovery time, even when blood flow is controlled for. The conclusion regarding the palette is that an optimum three-color palette can be chosen 'automatically', but the optimum choice of a 5-color palette cannot be made solely by optimizing the percentage of correct diagnoses

    In situ metal organic framework (ZIF-8) and mechanofusion-assisted MWCNT coating of LiFePO/C composite material for lithium-ion batteries

    Get PDF
    LiFePO4 is one of the industrial, scalable cathode materials in lithium-ion battery production, due to its cost-effectiveness and environmental friendliness. However, the electrochemical performance of LiFePO4 in high current rate operation is still limited, due to its poor ionic- and electron-conductive properties. In this study, a zeolitic imidazolate framework (ZIF-8) and multiwalled carbon nanotubes (MWCNT) modified LiFePO4/C (LFP) composite cathode materials were developed and investigated in detail. The ZIF-8 and MWCNT can be used as ionic- and electron-conductive materials, respectively. The surface modification of LFP by ZIF-8 and MWCNT was carried out through in situ wet chemical and mechanical alloy coating. The as-synthesized materials were scrutinized via various characterization methods, such as XRD, SEM, EDX, etc., to determine the material microstructure, morphology, phase, chemical composition, etc. The uniform and stable spherical morphology of LFP composites was obtained when the ZIF-8 coating was processed by the agitator [A], instead of the magnetic stirrer [MS], condition. It was found that the (optimum of) 2 wt.% ZIF-8@LFP [A]/MWCNT composite cathode material exhibited outstanding improvement in high-rate performance; it maintained the discharge capacities of 125 mAh g−1 at 1C, 110 mAh g−1 at 3C, 103 mAh g−1 at 5C, and 91 mAh g−1 at 10C. Better cycling stability with capacity retention of 75.82% at 1C for 100 cycles, as compared to other electrodes prepared in this study, was also revealed. These excellent results were mainly obtained because of the improvement of lithium-ion transport properties, less polarization effect, and interfacial impedance of the LFP composite cathode materials derived from the synergistic effect of both ZIF-8 and MWCNT coating materials

    Physician decision making in selection of second-line treatments in immune thrombocytopenia in children.

    Get PDF
    Immune thrombocytopenia (ITP) is an acquired autoimmune bleeding disorder which presents with isolated thrombocytopenia and risk of hemorrhage. While most children with ITP promptly recover with or without drug therapy, ITP is persistent or chronic in others. When needed, how to select second-line therapies is not clear. ICON1, conducted within the Pediatric ITP Consortium of North America (ICON), is a prospective, observational, longitudinal cohort study of 120 children from 21 centers starting second-line treatments for ITP which examined treatment decisions. Treating physicians reported reasons for selecting therapies, ranking the top three. In a propensity weighted model, the most important factors were patient/parental preference (53%) and treatment-related factors: side effect profile (58%), long-term toxicity (54%), ease of administration (46%), possibility of remission (45%), and perceived efficacy (30%). Physician, health system, and clinical factors rarely influenced decision-making. Patient/parent preferences were selected as reasons more often in chronic ITP (85.7%) than in newly diagnosed (0%) or persistent ITP (14.3%, P = .003). Splenectomy and rituximab were chosen for the possibility of inducing long-term remission (P < .001). Oral agents, such as eltrombopag and immunosuppressants, were chosen for ease of administration and expected adherence (P < .001). Physicians chose rituximab in patients with lower expected adherence (P = .017). Treatment choice showed some physician and treatment center bias. This study illustrates the complexity and many factors involved in decision-making in selecting second-line ITP treatments, given the absence of comparative trials. It highlights shared decision-making and the need for well-conducted, comparative effectiveness studies to allow for informed discussion between patients and clinicians

    MoO3 nanoparticle coatings on high-voltage 5 V LiNi0.5 Mn1.5 O4 cathode materials for improving lithium-ion battery performance

    Get PDF
    To reduce surface contamination and increase battery life, MoO3 nanoparticles were coated with a high-voltage (5 V) LiNi0.5 Mn1.5 O4 cathode material by in-situ method during the high-temperature annealing process. To avoid charging by more than 5 V, we also developed a system based on anode-limited full-cell with a negative/positive electrode (N/P) ratio of 0.9. The pristine LiNi0.5 Mn1.5 O4 was initially prepared by high-energy ball-mill with a solid-state reaction, followed by a precipitation reaction with a molybdenum precursor for the MoO3 coating. The typical structural and electrochemical behaviors of the materials were clearly investigated and reported. The results revealed that a sample of 2 wt.% MoO3-coated LiNi0.5 Mn1.5 O4 electrode exhibited an optimal electrochemical activity, indicating that the MoO3 nanoparticle coating layers considerably enhanced the high-rate charge–discharge profiles and cycle life performance of LiNi0.5 Mn1.5 O4 with a negligible capacity decay. The 2 wt.% MoO3-coated LiNi0.5 Mn1.5 O4 electrode could achieve high specific discharge capacities of 131 and 124 mAh g−1 at the rates of 1 and 10 C, respectively. In particular, the 2 wt.% MoO3-coated LiNi0.5 Mn1.5 O4 electrode retained its specific capacity (87 mAh g−1) of 80.1% after 500 cycles at a rate of 10 C. The Li4 Ti5 O12 /LiNi0.5 Mn1.5 O4 full cell based on the electrochemical-cell (EL-cell) configuration was successfully assembled and tested, exhibiting excellent cycling retention of 93.4% at a 1 C rate for 100 cycles. The results suggest that the MoO3 nano-coating layer could effectively reduce side reactions at the interface of the LiNi0.5 Mn1.5 O4 cathode and the electrolyte, thus improving the electrochemical performance of the battery system
    • …
    corecore