736 research outputs found

    Effects of hemoglobin-based oxygen carriers on blood coagulation.

    Get PDF
    For many decades, Hemoglobin-based oxygen carriers (HBOCs) have been central in the development of resuscitation agents that might provide oxygen delivery in addition to simple volume expansion. Since 80% of the world population lives in areas where fresh blood products are not available, the application of these new solutions may prove to be highly beneficial (Kim and Greenburg 2006). Many improvements have been made to earlier generation HBOCs, but various concerns still remain, including coagulopathy, nitric oxide scavenging, platelet interference and decreased calcium concentration secondary to volume expansion (Jahr et al. 2013). This review will summarize the current challenges faced in developing HBOCs that may be used clinically, in order to guide future research efforts in the field

    Better Not Sleep Under Water : A Comparison of Two Norwegian Films and their American Remakes

    Get PDF
    Close to half of the films produced in Hollywood every year are based on books, TV-series, comic books, cartoons or earlier films. Many of these earlier films are produced in other countries than the United States. Making a film based on another film can be a dangerous game, especially if that earlier film is a product of a different country and different culture. This thesis looks at the differences in remakes and their originary films, and more specifically the differences between the two Norwegian films Hodet over vannet (Nils Gaup, 1993) and Insomnia (Erik Skjoldbjærg, 1999) and their American remakes Head Above Water (Jim Wilson, 1996) and Insomnia (Christopher Nolan, 2002). The analysis focuses on the cultural and industry related differences that can be read out of comparing the films. The thesis makes the claim that the there are many pitfalls that a production company or a director can fall into when remaking a film from a different country, and that both the ideological content and the narrative structure of the films have to be reworked in order to make a successful cross-cultural remake

    Nucleosomes in serum as a marker for cell death

    Get PDF
    The concentration of nucleosomes is elevated in blood of patients with diseases which are associated with enhanced cell death. In order to detect these circulating nucleosomes, we used the Cell Death Detection-ELISA(Plus) (CDDE) from Roche Diagnostics (Mannheim, Germany) (details at http:\textbackslash{}\textbackslash{}biochem.roche.com). For its application in liquid materials we performed various modifications: we introduced a standard curve with nucleosome-rich material, which enabled direct quantification and improved comparability of the values within (CVinterassay:3.0-4.1%) and between several runs (CVinterassay:8.6-13.5%), and tested the analytical specificity of the ELISA. Because of the fast elimination of nucleosomes from circulation and their limited stability, we compared plasma and serum matrix and investigated in detail the pre-analytical handling of serum samples which can considerably influence the test results. Careless venipuncture producing hemolysis, delayed centrifugation and bacterial contamination of the blood samples led to false-positive results; delayed stabilization with EDTA and insufficient storage conditions resulted in false-negative values. At temperatures of -20 degreesC, serum samples which were treated with 10 mM EDTA were stable for at least 6 months. In order to avoid possible interfering factors, we recommend a schedule for the pre-analytical handling of the samples. As the first stage, the possible clinical application was investigated in the sera of 310 persons. Patients with solid tumors (n = 220; mean = 361 Arbitrary Units (AU)) had considerably higher values than healthy persons (n = 50; mean = 30 AU; P = 0.0001) and patients with inflammatory diseases (n = 40; mean = 296 AU; p = 0.096). Within the group of patients with tumors, those in advanced stages (UICC 4) showed significantly higher values than those in early stages (UICC 1-3) (P = 0.0004)

    Analysis of the intraspinal calcium dynamics and its implications on the plasticity of spiking neurons

    Full text link
    The influx of calcium ions into the dendritic spines through the N-metyl-D-aspartate (NMDA) channels is believed to be the primary trigger for various forms of synaptic plasticity. In this paper, the authors calculate analytically the mean values of the calcium transients elicited by a spiking neuron undergoing a simple model of ionic currents and back-propagating action potentials. The relative variability of these transients, due to the stochastic nature of synaptic transmission, is further considered using a simple Markov model of NMDA receptos. One finds that both the mean value and the variability depend on the timing between pre- and postsynaptic action-potentials. These results could have implications on the expected form of synaptic-plasticity curve and can form a basis for a unified theory of spike time-dependent, and rate based plasticity.Comment: 14 pages, 10 figures. A few changes in section IV and addition of a new figur

    Is there a bidirectional association between sedentary behaviour and cognitive decline in older adults? Findings from the Irish Longitudinal Study on Ageing

    Get PDF
    Research on whether sedentary behaviour (SB) is related to cognitive decline in older individuals is conflicting, potentially caused by methodological differences in previous studies. To inform public health policies, we analysed both the forward and reverse association across four-years between subjective TV time and objectively-measured SB and four cognitive outcome measures in older adults. The Irish Longitudinal Study on Ageing (TILDA) quantified time spent watching TV using a questionnaire and objective physical activity patterns with a GENEActiv accelerometer. Mixed model analysis examined whether these two measures of SB related to changes in cognitive function (immediate and delayed recall, MMSE, and animal naming task) during a four-year follow-up period. Furthermore, the reverse association between changes in cognition over the preceding four years and SB was investigated. We included 1,276 participants (67 ± 9 years). Longitudinally, every hour of objective SB per day was associated with a -0.01 (95%CI = -0.03;-0.00) lower MMSE score per year. Reversely, a worse decline in immediate and delayed recall over the preceding waves was related to slightly more objective SB (B = -0.24 (95%CI = -0.41;-0.07)) and TV time (B = -0.25 (95%CI = -0.48;-0.03)) at the end of those four years. To conclude, in healthy older individuals, higher levels of objective SB are related to cognitive decline across a four-year follow-up, although the magnitude and clinical relevance are questionable. As preceding cognitive decline is associated with more SB across follow-up, this suggests that a bidirectional association is plausible

    Circulating Cell-Free DNA in Dogs with Mammary Tumors: Short and Long Fragments and Integrity Index

    Get PDF
    Circulating cell-free DNA (cfDNA) has been considered an interesting diagnostic/prognostic plasma biomarker in tumor-bearing subjects. In cancer patients, cfDNA can hypothetically derive from tumor necrosis/apoptosis, lysed circulating cells, and some yet unrevealed mechanisms of active release. This study aimed to preliminarily analyze cfDNA in dogs with canine mammary tumors (CMTs). Forty-four neoplastic, 17 non-neoplastic disease-bearing, and 15 healthy dogs were recruited. Necrosis and apoptosis were also assessed as potential source of cfDNA on 78 CMTs diagnosed from the 44 dogs. The cfDNA fragments and integrity index significantly differentiated neoplastic versus non-neoplastic dogs (P<0.05), and allowed the distinction between benign and malignant lesions (P<0.05). Even if without statistical significance, the amount of cfDNA was also affected by tumor necrosis and correlated with tumor size and apoptotic markers expression. A significant (P<0.01) increase of Bcl-2 in malignant tumors was observed, and in metastatic CMTs the evasion of apoptosis was also suggested. This study, therefore, provides evidence that cfDNA could be a diagnostic marker in dogs carrying mammary nodules suggesting that its potential application in early diagnostic procedures should be further investigated

    Polymerized bovine hemoglobin solution as a replacement for allogeneic red blood cell transfusion after cardiac surgery: Results of a randomized, double-blind trial

    Get PDF
    AbstractBackground: Blood loss leading to reduced oxygen-carrying capacity is usually treated with red blood cell transfusions. This study examined the hypothesis that a hemoglobin-based oxygen-carrying solution can serve as an initial alternative to red blood cell transfusion. Methods: In a randomized, double-blind efficacy trial of HBOC-201, a total of 98 patients undergoing cardiac surgery and requiring transfusion were randomly assigned to receive either red blood cell units or HBOC-201 (Hemopure; Biopure Corporation, Cambridge, Mass) for the first three postoperative transfusions. Patients were monitored before and after transfusion, at discharge, and at 3 to 4 weeks after the operation for subsequent red blood cell use, hemodynamics, and clinical laboratory parameters. Results: The use of HBOC-201 eliminated the need for red blood cell transfusions in 34% of cases (95% confidence interval 21%-49%). Patients in the HBOC group received a mean of 1.72 subsequent units of red blood cells; those who received red blood cells only received a mean of 2.19 subsequent units (P =.05). Hematocrit values were transiently lower in the HBOC group but were similar in the two groups at discharge and follow-up. Oxygen extraction was greater in the HBOC group (P =.05). Mean increases in blood pressure were greater in the HBOC group, but not significantly so. Conclusion: HBOC-201 may be an initial alternative to red blood cell transfusions for patients with moderate anemia after cardiac surgery. In a third of cases, HBOC-201 eliminated the need for red blood cell transfusion, although substantial doses were needed to produce this modest degree of blood conservation.J Thorac Cardiovasc Surg 2002;124:35-4

    Selective laser melting-produced porous titanium scaffolds regenerate bone in critical size cortical bone defects

    Get PDF
    Porous titanium scaffolds have good mechanical properties that make them an interesting bone substitute material for large bone defects. These scaffolds can be produced with selective laser melting, which has the advantage of tailoring the structure's architecture. Reducing the strut size reduces the stiffness of the structure and may have a positive effect on bone formation. Two scaffolds with struts of 120-μm (titanium-120) or 230-μm (titanium-230) were studied in a load-bearing critical femoral bone defect in rats. The defect was stabilized with an internal plate and treated with titanium-120, titanium-230, or left empty. In vivo micro-CT scans at 4, 8, and 12 weeks showed more bone in the defects treated with scaffolds. Finally, 18.4 ± 7.1 mm3(titanium-120, p = 0.015) and 18.7 ± 8.0 mm3(titanium-230, p = 0.012) of bone was formed in those defects, significantly more than in the empty defects (5.8 ± 5.1 mm3). Bending tests on the excised femurs after 12 weeks showed that the fusion strength reached 62% (titanium-120) and 45% (titanium-230) of the intact contralateral femurs, but there was no significant difference between the two scaffolds. This study showed that in addition to adequate mechanical support, porous titanium scaffolds facilitate bone formation, which results in high mechanical integrity of the treated large bone defects. Copyrigh

    Absolute response of Fuji imaging plate detectors to picosecond-electron bunches

    Get PDF
    The characterization of the absolute number of electrons generated by laser wakefield acceleration often relies on absolutely calibrated FUJI imaging plates (IP), although their validity in the regime of extreme peak currents is untested. Here, we present an extensive study on the dependence of the sensitivity of BAS-SR and BAS-MS IP to picosecond electron bunches of varying charge of up to 60 pC, performed at the electron accelerator ELBE, making use of about three orders of magnitude of higher peak intensity than in prior studies. We demonstrate that the response of the IPs shows no saturation effect and that the BAS-SR IP sensitivity of 0.0081 photostimulated luminescence per electron number confirms surprisingly well data from previous works. However, the use of the identical readout system and handling procedures turned out to be crucial and, if unnoticed, may be an important error source

    Absolute response of Fuji imaging plate detectors to picosecond-electron bunches

    Get PDF
    The characterization of the absolute number of electrons generated by laser wakefield acceleration often relies on absolutely calibrated FUJI imaging plates (IP), although their validity in the regime of extreme peak currents is untested. Here, we present an extensive study on the dependence of the sensitivity of BAS-SR and BAS-MS IP to picosecond electron bunches of varying charge of up to 60 pC, performed at the electron accelerator ELBE, making use of about three orders of magnitude of higher peak intensity than in prior studies. We demonstrate that the response of the IPs shows no saturation effect and that the BAS-SR IP sensitivity of 0.0081 photostimulated luminescence per electron number confirms surprisingly well data from previous works. However, the use of the identical readout system and handling procedures turned out to be crucial and, if unnoticed, may be an important error source
    • …
    corecore