3,242 research outputs found

    On the complexity of some birational transformations

    Get PDF
    Using three different approaches, we analyze the complexity of various birational maps constructed from simple operations (inversions) on square matrices of arbitrary size. The first approach consists in the study of the images of lines, and relies mainly on univariate polynomial algebra, the second approach is a singularity analysis, and the third method is more numerical, using integer arithmetics. Each method has its own domain of application, but they give corroborating results, and lead us to a conjecture on the complexity of a class of maps constructed from matrix inversions

    Born's rule from measurements of classical signals by threshold detectors which are properly calibrated

    Full text link
    The very old problem of the statistical content of quantum mechanics (QM) is studied in a novel framework. The Born's rule (one of the basic postulates of QM) is derived from theory of classical random signals. We present a measurement scheme which transforms continuous signals into discrete clicks and reproduces the Born's rule. This is the sheme of threshold type detection. Calibration of detectors plays a crucial role.Comment: The problem of double clicks is resolved; hence, one can proceed in purely wave framework, i.e., the wave-partcile duality has been resolved in favor of the wave picture of prequantum realit

    SPIROC (SiPM Integrated Read-Out Chip): Dedicated very front-end electronics for an ILC prototype hadronic calorimeter with SiPM read-out

    Get PDF
    The SPIROC chip is a dedicated very front-end electronics for an ILC prototype hadronic calorimeter with Silicon photomultiplier (or MPPC) readout. This ASIC is due to equip a 10,000-channel demonstrator in 2009. SPIROC is an evolution of FLC_SiPM used for the ILC AHCAL physics prototype [1]. SPIROC was submitted in June 2007 and will be tested in September 2007. It embeds cutting edge features that fulfil ILC final detector requirements. It has been realized in 0.35m SiGe technology. It has been developed to match the requirements of large dynamic range, low noise, low consumption, high precision and large number of readout channels needed. SPIROC is an auto-triggered, bi-gain, 36-channel ASIC which allows to measure on each channel the charge from one photoelectron to 2000 and the time with a 100ps accurate TDC. An analogue memory array with a depth of 16 for each channel is used to store the time information and the charge measurement. A 12-bit Wilkinson ADC has been embedded to digitize the analogue memory content (time and charge on 2 gains). The data are then stored in a 4kbytes RAM. A very complex digital part has been integrated to manage all theses features and to transfer the data to the DAQ which is described on [2]

    Promoting RNA helical stacking via A-minor junctions

    Get PDF
    RNA molecules take advantage of prevalent structural motifs to fold and assemble into well-defined 3D architectures. The A-minor junction is a class of RNA motifs that specifically controls coaxial stacking of helices in natural RNAs. A sensitive self-assembling supra-molecular system was used as an assay to compare several natural and previously unidentified A-minor junctions by native polyacrylamide gel electrophoresis and atomic force microscopy. This class of modular motifs follows a topological rule that can accommodate a variety of interchangeable A-minor interactions with distinct local structural motifs. Overall, two different types of A-minor junctions can be distinguished based on their functional self-assembling behavior: one group makes use of triloops or GNRA and GNRA-like loops assembling with helices, while the other takes advantage of more complex tertiary receptors specific for the loop to gain higher stability. This study demonstrates how different structural motifs of RNA can contribute to the formation of topologically equivalent helical stacks. It also exemplifies the need of classifying RNA motifs based on their tertiary structural features rather than secondary structural features. The A-minor junction rule can be used to facilitate tertiary structure prediction of RNAs and rational design of RNA parts for nanobiotechnology and synthetic biology

    SPIROC (SiPM Integrated Read-Out Chip): Dedicated very front-end electronics for an ILC prototype hadronic calorimeter with SiPM read-out

    Get PDF
    The SPIROC chip is a dedicated very front-end electronics for an ILC prototype hadronic calorimeter with Silicon photomultiplier (or MPPC) readout. This ASIC is due to equip a 10,000-channel demonstrator in 2009. SPIROC is an evolution of FLC_SiPM used for the ILC AHCAL physics prototype [1]. SPIROC was submitted in June 2007 and will be tested in September 2007. It embeds cutting edge features that fulfil ILC final detector requirements. It has been realized in 0.35m SiGe technology. It has been developed to match the requirements of large dynamic range, low noise, low consumption, high precision and large number of readout channels needed. SPIROC is an auto-triggered, bi-gain, 36-channel ASIC which allows to measure on each channel the charge from one photoelectron to 2000 and the time with a 100ps accurate TDC. An analogue memory array with a depth of 16 for each channel is used to store the time information and the charge measurement. A 12-bit Wilkinson ADC has been embedded to digitize the analogue memory content (time and charge on 2 gains). The data are then stored in a 4kbytes RAM. A very complex digital part has been integrated to manage all theses features and to transfer the data to the DAQ which is described on [2]. After an exhaustive description, the extensive measurement results of that new front-end chip will be presented

    HPLC–Tandem Mass Spectrometric Method to Characterize Resveratrol Metabolism in Humans

    Get PDF
    AbstractBackground: Nutritional biomarkers are alternatives to traditional dietary assessment tools. We sought to develop a method for nutritional analysis of resveratrol, a phenolic compound with purported health-promoting properties, and to determine all resveratrol metabolites.Methods: We obtained LDL and urine samples from 11 healthy male volunteers who had consumed 250 mL of Merlot red wine. We measured resveratrol and its metabolites with 96-well solid-phase extraction plates coupled with HPLC-tandem mass spectrometry. Hexestrol was used as the internal standard. Gradient chromatography in multiple reaction monitoring mode was performed on a Luna C18 column, maintained at 40 °C; m/z transitions were as follows: resveratrol, 227/185; resveratrol glucosides, 389/227; resveratrol glucuronides, 403/227; resveratrol sulfates, 307/227; taxifolin, 303/285; and hexestrol, 269/134.Results: Standard calibration curves were linear at 4.4–3289.5 nmol/L. Residual analyses were 100% (3.2) for trans-resveratrol and 100% (11.1) for trans-piceid. In both matrices, imprecision (CV) was <10.8% at all concentrations. Detection limits for resveratrol were 0.2 nmol/L (LDL), 0.3 nmol/L (synthetic urine), and 4.0 nmol/L (blank urine). Resveratrol and metabolites were checked for stability, and no degradation was observed.Conclusions: The HPLC–tandem mass spectrometry method enabled us to identify resveratrol sulfates in human LDL and to characterize the complete profile of resveratrol metabolism in human LDL and urine. This method provides an accurate index of exposure to resveratrol and its metabolites, which can be used as nutritional biomarkers for evaluating the biological effects of moderate wine intake on human health

    Slow relaxations and history dependence of the transport properties of layered superconductors

    Full text link
    We study numerically the time evolution of the transport properties of layered superconductors after different preparations. We show that, in accordance with recent experiments in BSCCO performed in the second peak region of the phase diagram (Portier et al, 2001), the relaxation strongly depends on the initial conditions and is extremely slow. We investigate the dependence on the pinning center density and the perturbation applied. We compare the measurements to recent findings in tapped granular matter and we interpret our results with a rather simple picture.Comment: 4 pages, 4 fig
    • 

    corecore