448 research outputs found

    Impact of Reporting Bias in Network Meta-Analysis of Antidepressant Placebo-Controlled Trials

    Get PDF
    BACKGROUND: Indirect comparisons of competing treatments by network meta-analysis (NMA) are increasingly in use. Reporting bias has received little attention in this context. We aimed to assess the impact of such bias in NMAs. METHODS: We used data from 74 FDA-registered placebo-controlled trials of 12 antidepressants and their 51 matching publications. For each dataset, NMA was used to estimate the effect sizes for 66 possible pair-wise comparisons of these drugs, the probabilities of being the best drug and ranking the drugs. To assess the impact of reporting bias, we compared the NMA results for the 51 published trials and those for the 74 FDA-registered trials. To assess how reporting bias affecting only one drug may affect the ranking of all drugs, we performed 12 different NMAs for hypothetical analysis. For each of these NMAs, we used published data for one drug and FDA data for the 11 other drugs. FINDINGS: Pair-wise effect sizes for drugs derived from the NMA of published data and those from the NMA of FDA data differed in absolute value by at least 100% in 30 of 66 pair-wise comparisons (45%). Depending on the dataset used, the top 3 agents differed, in composition and order. When reporting bias hypothetically affected only one drug, the affected drug ranked first in 5 of the 12 NMAs but second (n = 2), fourth (n = 1) or eighth (n = 2) in the NMA of the complete FDA network. CONCLUSIONS: In this particular network, reporting bias biased NMA-based estimates of treatments efficacy and modified ranking. The reporting bias effect in NMAs may differ from that in classical meta-analyses in that reporting bias affecting only one drug may affect the ranking of all drugs

    The CEACAM1 expression is decreased in the liver of severely obese patients with or without diabetes

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Type 2 diabetes is mainly caused by insulin resistance. The carcinoembryonic antigen-related cell adhesion molecule 1 (CEACAM1) is an important candidate for causing insulin resistance.</p> <p>Methods</p> <p>The CEACAM1 expression was evaluated immunohistochemically in the liver tissues of 99 severely obese or non-obese subjects with or without diabetes. The CEACAM1 expression was classified into two categories: a normal expression or a decreased expression.</p> <p>Results</p> <p>The CEACAM1 expression was markedly decreased in the hepatocytes with macrovesicular steatosis. A decreased CEACAM1 expression was noted in 29 (29%) of 99 cases. The incidence of a decreased CEACAM1 expression was significantly higher in high grade fatty liver as well as severe obesity with or without diabetes (p < 0.05). The incidence of a decreased CEACAM1 expression was not different between the diabetic and non-diabetic groups.</p> <p>Conclusions</p> <p>This data supports that a decreased CEACAM1 expression is related to obesity and a fatty liver.</p

    Diagnostic and prognostic accuracy of clinical and laboratory parameters in community-acquired pneumonia

    Get PDF
    BACKGROUND: Community-acquired pneumonia (CAP) is the most frequent infection-related cause of death. The reference standard to diagnose CAP is a new infiltrate on chest radiograph in the presence of recently acquired respiratory signs and symptoms. This study aims to evaluate the diagnostic and prognostic accuracy of clinical signs and symptoms and laboratory biomarkers for CAP. METHODS: 545 patients with suspected lower respiratory tract infection, admitted to the emergency department of a university hospital were included in a pre-planned post-hoc analysis of two controlled intervention trials. Baseline assessment included history, clinical examination, radiography and measurements of procalcitonin (PCT), highly sensitive C-reactive protein (hsCRP) and leukocyte count. RESULTS: Of the 545 patients, 373 had CAP, 132 other respiratory tract infections, and 40 other final diagnoses. The AUC of a clinical model including standard clinical signs and symptoms (i.e. fever, cough, sputum production, abnormal chest auscultation and dyspnea) to diagnose CAP was 0.79 [95% CI, 0.75–0.83]. This AUC was significantly improved by including PCT and hsCRP (0.92 [0.89–0.94]; p < 0.001). PCT had a higher diagnostic accuracy (AUC, 0.88 [0.84–0.93]) in differentiating CAP from other diagnoses, as compared to hsCRP (AUC, 0.76 [0.69–0.83]; p < 0.001) and total leukocyte count (AUC, 0.69 [0.62–0.77]; p < 0.001). To predict bacteremia, PCT had a higher AUC (0.85 [0.80–0.91]) as compared to hsCRP (p = 0.01), leukocyte count (p = 0.002) and elevated body temperature (p < 0.001). PCT, in contrast to hsCRP and leukocyte count, increased with increasing severity of CAP, as assessed by the pneumonia severity index (p < 0.001). CONCLUSION: PCT, and to a lesser degree hsCRP, improve the accuracy of currently recommended approaches for the diagnosis of CAP, thereby complementing clinical signs and symptoms. PCT is useful in the severity assessment of CAP

    Detection of Gamma-Ray Emission from the Starburst Galaxies M82 and NGC 253 with the Large Area Telescope on Fermi

    Full text link
    We report the detection of high-energy gamma-ray emission from two starburst galaxies using data obtained with the Large Area Telescope on board the Fermi Gamma-ray Space Telescope. Steady point-like emission above 200 MeV has been detected at significance levels of 6.8 sigma and 4.8 sigma respectively, from sources positionally coincident with locations of the starburst galaxies M82 and NGC 253. The total fluxes of the sources are consistent with gamma-ray emission originating from the interaction of cosmic rays with local interstellar gas and radiation fields and constitute evidence for a link between massive star formation and gamma-ray emission in star-forming galaxies.Comment: Submitted to ApJ Letter

    A Multi-Stage Model for Fundamental Functional Properties in Primary Visual Cortex

    Get PDF
    Many neurons in mammalian primary visual cortex have properties such as sharp tuning for contour orientation, strong selectivity for motion direction, and insensitivity to stimulus polarity, that are not shared with their sub-cortical counterparts. Successful models have been developed for a number of these properties but in one case, direction selectivity, there is no consensus about underlying mechanisms. We here define a model that accounts for many of the empirical observations concerning direction selectivity. The model describes a single column of cat primary visual cortex and comprises a series of processing stages. Each neuron in the first cortical stage receives input from a small number of on-centre and off-centre relay cells in the lateral geniculate nucleus. Consistent with recent physiological evidence, the off-centre inputs to cortex precede the on-centre inputs by a small (∼4 ms) interval, and it is this difference that confers direction selectivity on model neurons. We show that the resulting model successfully matches the following empirical data: the proportion of cells that are direction selective; tilted spatiotemporal receptive fields; phase advance in the response to a stationary contrast-reversing grating stepped across the receptive field. The model also accounts for several other fundamental properties. Receptive fields have elongated subregions, orientation selectivity is strong, and the distribution of orientation tuning bandwidth across neurons is similar to that seen in the laboratory. Finally, neurons in the first stage have properties corresponding to simple cells, and more complex-like cells emerge in later stages. The results therefore show that a simple feed-forward model can account for a number of the fundamental properties of primary visual cortex

    Dacron® vs. PTFE as bypass materials in peripheral vascular surgery – systematic review and meta-analysis

    Get PDF
    Roll S, Müller-Nordhorn J, Keil T, et al. Dacron® vs. PTFE as bypass materials in peripheral vascular surgery – systematic review and meta-analysis. BMC Surgery. 2008;8(1): 22.Background: In peripheral vascular bypass surgery different synthetic materials are available for bypass grafting. It is unclear which of the two commonly used materials, polytetrafluoroethylene (PTFE) or polyester (Dacron®) grafts, is to be preferred. Thus, the aim of this meta-analysis and systematic review was to compare the effectiveness of these two prosthetic bypass materials (Dacron® and PTFE). Methods: We performed a systematic literature search in MEDLINE, Cochrane-Library – CENTRAL, EMBASE and other databases for relevant publications in English and German published between 1999 and 2008. Only randomized controlled trials were considered for inclusion. We assessed the methodological quality by means of standardized checklists. Primary patency was used as the main endpoint. Random-effect meta-analysis as well as pooling data in life table format was performed to combine study results. Results: Nine randomized controlled trials (RCT) were included. Two trials showed statistically significant differences in primary patency, one favouring Dacron® and one favouring PTFE grafts, while 7 trials did not show statistically significant differences between the two materials. Meta-analysis on the comparison of PTFE vs. Dacron® grafts yielded no differences with regard to primary patency rates (hazard ratio 1.04 (95% confidence interval [0.85;1.28]), no significant heterogeneity (p = 0.32, I2 = 14%)). Similarly, there were no significant differences with regard to secondary patency rates. Conclusion: Systematic evaluation and meta-analysis of randomized controlled trials comparing Dacron® and PTFE as bypass materials for peripheral vascular surgery showed no evidence of an advantage of one synthetic material over the other

    Bringing the real world into the fMRI scanner: Repetition effects for pictures versus real objects

    Get PDF
    Our understanding of the neural underpinnings of perception is largely built upon studies employing 2-dimensional (2D) planar images. Here we used slow event-related functional imaging in humans to examine whether neural populations show a characteristic repetition-related change in haemodynamic response for real-world 3-dimensional (3D) objects, an effect commonly observed using 2D images. As expected, trials involving 2D pictures of objects produced robust repetition effects within classic object-selective cortical regions along the ventral and dorsal visual processing streams. Surprisingly, however, repetition effects were weak, if not absent on trials involving the 3D objects. These results suggest that the neural mechanisms involved in processing real objects may therefore be distinct from those that arise when we encounter a 2D representation of the same items. These preliminary results suggest the need for further research with ecologically valid stimuli in other imaging designs to broaden our understanding of the neural mechanisms underlying human vision
    • …
    corecore