2,256 research outputs found

    Relating Space Radiation Environments to Risk Estimates

    Full text link

    Surface topography of hydroxyapatite affects ROS17/2.8 cells response

    Get PDF
    Hydroxyapatite (HA) has been used in orthopedic, dental, and maxillofacial surgery as a bone substitute. The aim of this investigation was to study the effect of surface topography produced by the presence of microporosity on cell response, evaluating: cell attachment, cell morphology, cell proliferation, total protein content, and alkaline phosphatase (ALP) activity. HA discs with different percentages of microporosity (< 5%, 15%, and 30%) were confected by means of the combination of uniaxial powder pressing and different sintering conditions. ROS17/2.8 cells were cultured on HA discs. For the evaluation of attachment, cells were cultured for two hours. Cell morphology was evaluated after seven days. After seven and fourteen days, cell proliferation, total protein content, and ALP activity were measured. Data were compared by means of ANOVA and Duncan’s multiple range test, when appropriate. Cell attachment (p = 0.11) and total protein content (p = 0.31) were not affected by surface topography. Proliferation after 7 and 14 days (p = 0.0007 and p = 0.003, respectively), and ALP activity (p = 0.0007) were both significantly decreased by the most irregular surface (HA30). These results suggest that initial cell events were not affected by surface topography, while surfaces with more regular topography, as those present in HA with 15% or less of microporosity, favored intermediary and final events such as cell proliferation and ALP activity

    Helium in the adult critical care setting

    Get PDF
    Helium is a low-density inert gas whose physical properties are very different from those of nitrogen and oxygen. Such properties could be clinically useful in the adult critical care setting, especially in patients with upper to more distal airway obstruction requiring moderate to intermediate levels of FiO2. However, despite decades of utilization and reporting, it is still difficult to give any firm clinical recommendation in this setting. Numerous case reports are available in the context of upper airway obstruction of different origins, but there is a lack of controlled studies for this indication. One study reported a helium-induced beneficial effect on surrogates of work of breathing after extubation in non-COPD patients, possibly in relation to laryngeal consequences of tracheal intubation. Physiological benefits of helium-oxygen breathing have been demonstrated in the context of acute severe asthma, but there is a lack of large controlled studies demonstrating an effect on pertinent clinical endpoints, except for a study reported only as an abstract, which mentioned a reduction in the intubation rate in helium-treated patients. Finally, there are a number of physiological studies in the context of COLD-COPD patients demonstrating a beneficial effect, mainly by a reduction in the resistive inspiratory work of breathing but also by a reduction in hyperinflation. Reduction of hypercapnia was mainly observed in spontaneously breathing and noninvasively ventilated helium-treated patients but not in intubated patients during controlled ventilation, suggesting that the decrease in PaCO2 was mainly in relation to a diminution in CO2 production, related to the diminution in work of breathing and not an improved alveolar ventilation. Moreover, there is little evidence that helium-oxygen could improve parameters of heterogeneity in such patients. Two RCTs were unable to demonstrate a reduction in the intubation rate in such setting, but they were likely underpowered. An adequately powered international multicentric study is ongoing and will help to determinate the exact place of the helium-oxygen mixture in the future. The place of the mixture during the weaning period will deserve further evaluation

    Fabrication of cell container arrays with overlaid surface topographies

    Get PDF
    This paper presents cell culture substrates in the form of microcontainer arrays with overlaid surface topographies, and a technology for their fabrication. The new fabrication technology is based on microscale thermoforming of thin polymer films whose surfaces are topographically prepatterned on a micro- or nanoscale. For microthermoforming, we apply a new process on the basis of temporary back moulding of polymer films and use the novel concept of a perforated-sheet-like mould. Thermal micro- or nanoimprinting is applied for prepatterning. The novel cell container arrays are fabricated from polylactic acid (PLA) films. The thin-walled microcontainer structures have the shape of a spherical calotte merging into a hexagonal shape at their upper circumferential edges. In the arrays, the cell containers are arranged densely packed in honeycomb fashion. The inner surfaces of the highly curved container walls are provided with various topographical micro- and nanopatterns. For a first validation of the microcontainer arrays as in vitro cell culture substrates, C2C12 mouse premyoblasts are cultured in containers with microgrooved surfaces and shown to align along the grooves in the three-dimensional film substrates. In future stem-cell-biological and tissue engineering applications, microcontainers fabricated using the proposed technology may act as geometrically defined artificial microenvironments or niches
    corecore