37 research outputs found

    Implementing a 48 h EWTD-compliant rota for junior doctors in the UK does not compromise patients’ safety : assessor-blind pilot comparison

    Get PDF
    Background: There are currently no field data about the effect of implementing European Working Time Directive (EWTD)-compliant rotas in a medical setting. Surveys of doctors’ subjective opinions on shift work have not provided reliable objective data with which to evaluate its efficacy. Aim: We therefore studied the effects on patient's safety and doctors’ work-sleep patterns of implementing an EWTD-compliant 48 h work week in a single-blind intervention study carried out over a 12-week period at the University Hospitals Coventry & Warwickshire NHS Trust. We hypothesized that medical error rates would be reduced following the new rota. Methods: Nineteen junior doctors, nine studied while working an intervention schedule of <48 h per week and 10 studied while working traditional weeks of <56 h scheduled hours in medical wards. Work hours and sleep duration were recorded daily. Rate of medical errors (per 1000 patient-days), identified using an established active surveillance methodology, were compared for the Intervention and Traditional wards. Two senior physicians blinded to rota independently rated all suspected errors. Results: Average scheduled work hours were significantly lower on the intervention schedule [43.2 (SD 7.7) (range 26.0–60.0) vs. 52.4 (11.2) (30.0–77.0) h/week; P < 0.001], and there was a non-significant trend for increased total sleep time per day [7.26 (0.36) vs. 6.75 (0.40) h; P = 0.095]. During a total of 4782 patient-days involving 481 admissions, 32.7% fewer total medical errors occurred during the intervention than during the traditional rota (27.6 vs. 41.0 per 1000 patient-days, P = 0.006), including 82.6% fewer intercepted potential adverse events (1.2 vs. 6.9 per 1000 patient-days, P = 0.002) and 31.4% fewer non-intercepted potential adverse events (16.6 vs. 24.2 per 1000 patient-days, P = 0.067). Doctors reported worse educational opportunities on the intervention rota. Conclusions: Whilst concerns remain regarding reduced educational opportunities, our study supports the hypothesis that a 48 h work week coupled with targeted efforts to improve sleep hygiene improves patient safety

    Structural and biochemical characterization of HP0315 from Helicobacter pylori as a VapD protein with an endoribonuclease activity

    Get PDF
    VapD-like virulence-associated proteins have been found in many organisms, but little is known about this protein family including the 3D structure of these proteins. Recently, a relationship between the Cas2 family of ribonucleases associated with the CRISPR system of microbial immunity and VapD was suggested. Here, we show for the first time the structure of a member of the VapD family and present a relationship of VapD with Cas2 family and toxin–antitoxin (TA) systems. The crystal structure of HP0315 from Helicobacter pylori was solved at a resolution of 2.8 Å. The structure of HP0315, which has a modified ferredoxin-like fold, is very similar to that of the Cas2 family. Like Cas2 proteins, HP0315 shows endoribonuclease activity. HP0315-cleaved mRNA, mainly before A and G nucleotides preferentially, which means that HP0315 has purine-specific endoribonuclease activity. Mutagenesis studies of HP0315 revealed that D7, L13, S43 and D76 residues are important for RNase activity, in contrast, to the Cas2 family. HP0315 is arranged as an operon with HP0316, which was found to be an antitoxin-related protein. However, HP0315 is not a component of the TA system. Thus, HP0315 may be an evolutionary intermediate which does not belong to either the Cas2 family or TA system

    Commercial Nucleic-Acid Amplification Tests for Diagnosis of Pulmonary Tuberculosis in Respiratory Specimens: Meta-Analysis and Meta-Regression

    Get PDF
    BACKGROUND: Hundreds of studies have evaluated the diagnostic accuracy of nucleic-acid amplification tests (NAATs) for tuberculosis (TB). Commercial tests have been shown to give more consistent results than in-house assays. Previous meta-analyses have found high specificity but low and highly variable estimates of sensitivity. However, reasons for variability in study results have not been adequately explored. We performed a meta-analysis on the accuracy of commercial NAATs to diagnose pulmonary TB and meta-regression to identify factors that are associated with higher accuracy. METHODOLOGY/PRINCIPAL FINDINGS: We identified 2948 citations from searching the literature. We found 402 articles that met our eligibility criteria. In the final analysis, 125 separate studies from 105 articles that reported NAAT results from respiratory specimens were included. The pooled sensitivity was 0.85 (range 0.36-1.00) and the pooled specificity was 0.97 (range 0.54-1.00). However, both measures were significantly heterogeneous (p<.001). We performed subgroup and meta-regression analyses to identify sources of heterogeneity. Even after stratifying by type of commercial test, we could not account for the variability. In the meta-regression, the threshold effect was significant (p = .01) and the use of other respiratory specimens besides sputum was associated with higher accuracy. CONCLUSIONS/SIGNIFICANCE: The sensitivity and specificity estimates for commercial NAATs in respiratory specimens were highly variable, with sensitivity lower and more inconsistent than specificity. Thus, summary measures of diagnostic accuracy are not clinically meaningful. The use of different cut-off values and the use of specimens other than sputum could explain some of the observed heterogeneity. Based on these observations, commercial NAATs alone cannot be recommended to replace conventional tests for diagnosing pulmonary TB. Improvements in diagnostic accuracy, particularly sensitivity, need to be made in order for this expensive technology to be worthwhile and beneficial in low-resource countries
    corecore