730 research outputs found

    Dipolar reorientation and phase transitions in mixed alkali-halide-alkali-cyanide crystals

    Get PDF
    We show that the results of LĂŒty and Ortiz-Lopez relating the cyanide reorientation rates to the high-temperature phase diagrams of alkali-halide-alkali-cyanide mixed crystals can be understood within simple mean-field theory

    Induction of Colonic Aberrant Crypts in Mice by Feeding Apparent N-Nitroso Compounds Derived From Hot Dogs

    Get PDF
    Nitrite-preserved meats (e.g., hot dogs) may help cause colon cancer because they contain N-nitroso compounds. We tested whether purified hot-dog-derived total apparent N-nitroso compounds (ANC) could induce colonic aberrant crypts, which are putative precursors of colon cancer. We purified ANC precursors in hot dogs and nitrosated them to produce ANC. In preliminary tests, CF1 mice received 1 or 3 i.p. injections of 5mg azoxymethane (AOM)/kg. In Experiments 1 and 2, female A/J mice received ANC in diet. In Experiment 1, ANC dose initially dropped sharply because the ANC precursors had mostly decomposed but, later in Experiment 1 and throughout Experiment 2, ANC remained at 85 nmol/g diet. Mice were killed after 8 (AOM tests) or 17–34 (ANC tests) wk.Median numbers of aberrant crypts in the distal 2 cm of the colon for 1 and 3 AOMinjections, CF1 controls, ANC (Experiment 1), ANC (Experiment 2),and untreated A/J mice were 31, 74, 12, 20, 12, and 5–6, with P < 0.01 for both ANC tests. Experiment 2 showed somewhat increased numbers of colonic mucin-depleted foci in the ANC-treated group. We conclude that hot-dog-derived ANC induced significant numbers of aberrant crypts in the mouse colon

    3. Launching the New Enterprise

    Get PDF
    As the academic year of 1945-46 approached, the intensity of activity in preparation for actually opening the school in the fall term became overwhelming. Incredible though it may seem, Ives and Day were able in a period of a few weeks to assemble the nucleus of a faculty, several of whom formed a continuing source of counsel and advice both during the school’s formative years and thereafter. Includes: The First Dean and the School’s Dedication; A Participant’s View of the Early Years; Ives Moves On; Several Views of Martin P. Catherwood; The Founders

    The Impact of Operation Bushmaster on Medical Student Decision-making in a High-Stress, Operational Environment.

    Get PDF
    INTRODUCTION: Operation Bushmaster is a high-fidelity military medical field practicum for fourth-year medical students at the Uniformed Services University. During Operation Bushmaster, students treat live-actor and mannequin-based simulated patients in wartime scenarios throughout the five-day practicum. This study explored the impact of participating in Operation Bushmaster on students\u27 decision-making in a high-stress, operational environment, a crucial aspect of their future role as military medical officers. MATERIALS AND METHODS: A panel of emergency medicine physician experts used a modified Delphi technique to develop a rubric to evaluate the participants\u27 decision-making abilities under stress. The participants\u27 decision-making was assessed before and after participating in either Operation Bushmaster (control group) or completing asynchronous coursework (experimental group). A paired-samples t-test was conducted to detect any differences between the means of the participants\u27 pre- and posttest scores. This study was approved by the Institutional Review Board at Uniformed Services University #21-13079. RESULTS: A significant difference was detected in the pre- and posttest scores of students who attended Operation Bushmaster (P \u3c .001), while there was no significant difference in the pre- and posttest scores of students who completed online, asynchronous coursework (P = .554). CONCLUSION: Participating in Operation Bushmaster significantly improved the control group participants\u27 medical decision-making under stress. The results of this study confirm the effectiveness of high-fidelity simulation-based education for teaching decision-making skills to military medical students

    ACC/AHA guidelines for percutaneous coronary intervention (revision of the 1993 PTCA guidelines)—executive summary21When citing this document, the American College of Cardiology and the American Heart Association would appreciate the following citation format: Smith SC, Jr, Dove JT, Jacobs AK, Kennedy JW, Kereiakes D, Kern MJ, Kuntz RE, Popma JJ, Schaff HV, Williams DO. ACC/AHA guidelines for percutaneous coronary intervention: executive summary and recommendations: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Committee to Revise the 1993 Guidelines for Percutaneous Transluminal Coronary Angioplasty). J Am Coll Cardiol 2001;37:2215–38.22Address for reprints: a single reprint of this document is available by calling 800-253-4636 (US only) or writing the American College of Cardiology, Educational Services, 9111 Old Georgetown Road, Bethesda, MD 20814-1699. This document (reprint no. 71-0205), as well as the companion full-text guideline (reprint no. 71-0206), are available on the ACC Web site at www.acc.organd the AHA Web site at http://www.americanheart.org. To purchase additional reprints (specify version): up to 999 copies, call 800-611-6083 (US only) or fax 413-665-2671; 1000 or more copies, call 214-706-1466, fax 214-691-6342; or E-mail: [email protected]. A report of the American College of Cardiology/American Heart Association Task Force on practice guidelines (Committee to revise the 1993 guidelines for percutaneous transluminal coronary angioplasty) endorsed by the Society for Cardiac Angiography and Interventions

    Get PDF

    PatientĂą level Factors and the Quality of Care Delivered in Pediatric Emergency Departments

    Full text link
    ObjectiveQuality of care delivered to adult patients in the emergency department (ED) is often associated with demographic and clinical factors such as a patient’s race/ethnicity and insurance status. We sought to determine whether the quality of care delivered to children in the ED was associated with a variety of patientñ level factors.MethodsThis was a retrospective, observational cohort study. Pediatric patients (<18 years) who received care between January 2011 and December 2011 at one of 12 EDs participating in the Pediatric Emergency Care Applied Research Network (PECARN) were included. We analyzed demographic factors (including age, sex, and payment source) and clinical factors (including triage, chief complaint, and severity of illness). We measured quality of care using a previously validated implicit review instrument using chart review with a summary score that ranged from 5 to 35. We examined associations between demographic and clinical factors and quality of care using a hierarchical multivariable linear regression model with hospital site as a random effect.ResultsIn the multivariable model, among the 620 ED encounters reviewed, we did not find any association between patient age, sex, race/ethnicity, and payment source and the quality of care delivered. However, we did find that some chief complaint categories were significantly associated with lower than average quality of care, including fever (ñ 0.65 points in quality, 95% confidence interval [CI] = ñ 1.24 to ñ 0.06) and upper respiratory symptoms (ñ 0.68 points in quality, 95% CI = ñ 1.30 to ñ 0.07).ConclusionWe found that quality of ED care delivered to children among a cohort of 12 EDs participating in the PECARN was high and did not differ by patient age, sex, race/ethnicity, and payment source, but did vary by the presenting chief complaint.Peer Reviewedhttps://deepblue.lib.umich.edu/bitstream/2027.42/142981/1/acem13347_am.pdfhttps://deepblue.lib.umich.edu/bitstream/2027.42/142981/2/acem13347-sup-0001-DataSupplementS1.pdfhttps://deepblue.lib.umich.edu/bitstream/2027.42/142981/3/acem13347.pdfhttps://deepblue.lib.umich.edu/bitstream/2027.42/142981/4/acem13347-sup-0002-DataSupplementS2.pd

    LSST: from Science Drivers to Reference Design and Anticipated Data Products

    Get PDF
    (Abridged) We describe here the most ambitious survey currently planned in the optical, the Large Synoptic Survey Telescope (LSST). A vast array of science will be enabled by a single wide-deep-fast sky survey, and LSST will have unique survey capability in the faint time domain. The LSST design is driven by four main science themes: probing dark energy and dark matter, taking an inventory of the Solar System, exploring the transient optical sky, and mapping the Milky Way. LSST will be a wide-field ground-based system sited at Cerro Pach\'{o}n in northern Chile. The telescope will have an 8.4 m (6.5 m effective) primary mirror, a 9.6 deg2^2 field of view, and a 3.2 Gigapixel camera. The standard observing sequence will consist of pairs of 15-second exposures in a given field, with two such visits in each pointing in a given night. With these repeats, the LSST system is capable of imaging about 10,000 square degrees of sky in a single filter in three nights. The typical 5σ\sigma point-source depth in a single visit in rr will be ∌24.5\sim 24.5 (AB). The project is in the construction phase and will begin regular survey operations by 2022. The survey area will be contained within 30,000 deg2^2 with ÎŽ<+34.5∘\delta<+34.5^\circ, and will be imaged multiple times in six bands, ugrizyugrizy, covering the wavelength range 320--1050 nm. About 90\% of the observing time will be devoted to a deep-wide-fast survey mode which will uniformly observe a 18,000 deg2^2 region about 800 times (summed over all six bands) during the anticipated 10 years of operations, and yield a coadded map to r∌27.5r\sim27.5. The remaining 10\% of the observing time will be allocated to projects such as a Very Deep and Fast time domain survey. The goal is to make LSST data products, including a relational database of about 32 trillion observations of 40 billion objects, available to the public and scientists around the world.Comment: 57 pages, 32 color figures, version with high-resolution figures available from https://www.lsst.org/overvie

    LSST Science Book, Version 2.0

    Get PDF
    A survey that can cover the sky in optical bands over wide fields to faint magnitudes with a fast cadence will enable many of the exciting science opportunities of the next decade. The Large Synoptic Survey Telescope (LSST) will have an effective aperture of 6.7 meters and an imaging camera with field of view of 9.6 deg^2, and will be devoted to a ten-year imaging survey over 20,000 deg^2 south of +15 deg. Each pointing will be imaged 2000 times with fifteen second exposures in six broad bands from 0.35 to 1.1 microns, to a total point-source depth of r~27.5. The LSST Science Book describes the basic parameters of the LSST hardware, software, and observing plans. The book discusses educational and outreach opportunities, then goes on to describe a broad range of science that LSST will revolutionize: mapping the inner and outer Solar System, stellar populations in the Milky Way and nearby galaxies, the structure of the Milky Way disk and halo and other objects in the Local Volume, transient and variable objects both at low and high redshift, and the properties of normal and active galaxies at low and high redshift. It then turns to far-field cosmological topics, exploring properties of supernovae to z~1, strong and weak lensing, the large-scale distribution of galaxies and baryon oscillations, and how these different probes may be combined to constrain cosmological models and the physics of dark energy.Comment: 596 pages. Also available at full resolution at http://www.lsst.org/lsst/sciboo

    Clinical Trial Protocol for PRIMARY2: A Multicentre, Phase 3, Randomised Controlled Trial Investigating the Additive Diagnostic Value of [68Ga]Ga-PSMA-11 Positron Emission Tomography/Computed Tomography in Men with Negative or Equivocal Multiparametric Magnetic Resonance Imaging for the Diagnosis of Clinically Significant Prostate Cancer

    Get PDF
    BACKGROUND: Multiparametric magnetic resonance imaging (mpMRI) has an established role for the diagnosis of clinically significant prostate cancer (sPCa). The PRIMARY trial demonstrated that [68Ga]Ga-PSMA-11 positron emission tomography/computed tomography (PET/CT) was associated with a significant improvement in sensitivity and negative predictive value for sPCa detection. OBJECTIVE: To demonstrate that addition of prostate-specific membrane antigen (PSMA) radioligand PET/CT will enable some men to avoid transperineal prostate biopsy without missing sPCa, and will facilitate biopsy targeting of PSMA-avid sites. DESIGN, SETTING, AND PARTICIPANTS: This multicentre, two-arm, phase 3, randomised controlled trial will recruit 660 participants scheduled to undergo biopsy. Eligible participants will have clinical suspicion of sPCa with a Prostate Imaging-Reporting and Data System (PI-RADS) score of 2 and red flags, or a PI-RADS score of 3 on mpMRI (PI-RADS v2). Participants will be randomised at a 1:1 ratio in permuted blocks stratified by centre. The trial is registered on ClinicalTrials.gov as NCT05154162. INTERVENTION: In the experimental arm, participants will undergo pelvic PSMA PET/CT. Local and central reviewers will interpret scans independently using the PRIMARY score. Participants with a positive result will undergo targeted transperineal prostate biopsies, whereas those with a negative result will undergo prostate-specific antigen monitoring alone. In the control arm, all participants undergo template transperineal prostate biopsies. Participants will be followed for subsequent clinical care for up to 2 yr after randomisation. OUTCOME MEASUREMENTS AND STATISTICAL ANALYSIS: sPCa is defined as Gleason score 3 + 4 (≄10%) = 7 disease (grade group 2) or higher on transperineal prostate biopsy. Avoidance of transperineal prostate biopsy will be measured at 6 mo from randomisation. The primary endpoints will be analysed on an intention-to-treat basis. CONCLUSIONS: Patient enrolment began in March 2022, with recruitment expected to take 36 mo. PATIENT SUMMARY: For patients with suspected prostate cancer who have nonsuspicious or unclear MRI (magnetic resonance imaging) scan findings, a different type of scan (called PSMA PET/CT; prostate-specific membrane antigen positron emission tomography/computed tomography) may identify men who could avoid an invasive prostate biopsy. This type of scan could also help urologists in better targeting of samples from suspicious lesions during prostate biopsies
    • 

    corecore