50 research outputs found

    Wake response to an ocean-feedback mechanism: Madeira Island case study

    Full text link
    This discussion focused on the numerical study of a wake episode. The Weather Research and Forecasting model was used in a downscale mode. The current literature focuses the discussion on the adiabatic dynamics of atmospheric wakes. Changes in mountain height and consequently on its relation to the atmospheric inversion layer should explain the shift in wake regimes: from a 'strong-wake' to a 'weak-wake' scenario. Nevertheless, changes in SST variability can also induce similar regime shifts. Increase in evaporation, contributes to increase convection and thus to an uplift of the stratified atmospheric layer, above the critical height, with subsequent internal gravity wave activity.Comment: Under review proces

    Failure of dual radius hydroxyapatite-coated acetabular cups

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>Many kind of hydroxyapatite-coated cups were used, with favorable results in short term studies; it was supposed that its use could improve osteointegration of the cup, enhancing thus stability and survivorship. The purpose of this study is to analyze the long term behavior of the hemispheric HA coated, Dual Radius Osteonics cup and to discuss the way of failure through the exam of the revised components and of both periacetabular and osteolysis tissue.</p> <p>Materials and Methods</p> <p>Between 1994 and 1997, at the Department of Orthopedic Sciences of the Insubria University, using the posterolateral approach, were implanted 276 Dual Radius Osteonics<sup>® </sup>in 256 patients, with mean age of 63 years.</p> <p>Results</p> <p>At a mean follow-up of 10 years (range 8–12 years), 183 cups in 165 patients, were available for clinical and radiographical evaluation. 22 Cups among the 183 were revised (11%). The cause of revision was aseptic loosening in 17 cases, septic loosening in one case, periprosthetic fracture in another case, osteolysis and polyethylene wear in two cases and, finally, recurrent dislocations in the last one. In the remaining patients, mean HHS increased from a preoperative value of 50,15 to a postoperative value of 92,69. The mean polyethylene wear was 1,25 mm (min. 0,08, max. 3,9 mm), with a mean annual wear of 0,17 mm. The mean acetabular migration on the two axis was 1,6 mm and 1,8 mm. Peri-acetabular osteolysis were recorded in 89% of the implants (163 cases). The cumulative survivorship (revision as endpoint) at the time was 88,9%.</p> <p>Conclusion</p> <p>Our study confirms the bad behavior of this type of cup probably related to the design, to the method of HA fixation. The observations carried out on the revised cup confirm these hypotheses but did not clarify if the third body wear could be a further problem. Another interesting aspect is the high incidence of osteolysis, which are often asymptomatic becoming a problem for the surgeon as the patient refuses the possibility of a revision.</p

    Do dividends signal future earnings in the Nordic stock markets?

    Get PDF
    We study the informational content of dividends on three Nordic civil law markets, where other simultaneous but blurring motives for dividends may be weaker. Using aggregate data on real earnings per share and payout ratios, long time series from 1969 to 2010, and methodologies which address problems of endogeneity, non-stationarity and autocorrelation (including a Vector Error Correction Model approach), we find evidence on dividend signaling in Nordic markets. However, we also find heterogeneity in the relationship between dividends and earnings on markets similar in many respects, suggesting that even small variations in the institutional surroundings may be important for the results

    3D bite modeling and feeding mechanics of the largest living amphibian, the Chinese Giant Salamander Andrias davidianus (Amphibia:Urodela)

    Get PDF
    Biting is an integral feature of the feeding mechanism for aquatic and terrestrial salamanders to capture, fix or immobilize elusive or struggling prey. However, little information is available on how it works and the functional implications of this biting system in amphibians although such approaches might be essential to understand feeding systems performed by early tetrapods. Herein, the skull biomechanics of the Chinese giant salamander, Andrias davidianus is investigated using 3D finite element analysis. The results reveal that the prey contact position is crucial for the structural performance of the skull, which is probably related to the lack of a bony bridge between the posterior end of the maxilla and the anterior quadrato-squamosal region. Giant salamanders perform asymmetrical strikes. These strikes are unusual and specialized behavior but might indeed be beneficial in such sit-and-wait or ambush-predators to capture laterally approaching prey. However, once captured by an asymmetrical strike, large, elusive and struggling prey have to be brought to the anterior jaw region to be subdued by a strong bite. Given their basal position within extant salamanders and theirPeer ReviewedPostprint (published version
    corecore