130 research outputs found
The Mid-Infrared Instrument for the James Webb Space Telescope, V: Predicted Performance of the MIRI Coronagraphs
The imaging channel on the Mid-Infrared Instrument (MIRI) is equipped with
four coronagraphs that provide high contrast imaging capabilities for studying
faint point sources and extended emission that would otherwise be overwhelmed
by a bright point-source in its vicinity. Such bright sources might include
stars that are orbited by exoplanets and circumstellar material, mass-loss
envelopes around post-main-sequence stars, the near-nuclear environments in
active galaxies, and the host galaxies of distant quasars. This paper describes
the coronagraphic observing modes of MIRI, as well as performance estimates
based on measurements of the MIRI flight model during cryo-vacuum testing. A
brief outline of coronagraphic operations is also provided. Finally, simulated
MIRI coronagraphic observations of a few astronomical targets are presented for
illustration
Optical performance of the JWST MIRI flight model: characterization of the point spread function at high-resolution
The Mid Infra Red Instrument (MIRI) is one of the four instruments onboard
the James Webb Space Telescope (JWST), providing imaging, coronagraphy and
spectroscopy over the 5-28 microns band. To verify the optical performance of
the instrument, extensive tests were performed at CEA on the flight model (FM)
of the Mid-InfraRed IMager (MIRIM) at cryogenic temperatures and in the
infrared. This paper reports on the point spread function (PSF) measurements at
5.6 microns, the shortest operating wavelength for imaging. At 5.6 microns the
PSF is not Nyquist-sampled, so we use am original technique that combines a
microscanning measurement strategy with a deconvolution algorithm to obtain an
over-resolved MIRIM PSF. The microscanning consists in a sub-pixel scan of a
point source on the focal plane. A data inversion method is used to reconstruct
PSF images that are over-resolved by a factor of 7 compared to the native
resolution of MIRI. We show that the FWHM of the high-resolution PSFs were
5-10% wider than that obtained with Zemax simulations. The main cause was
identified as an out-of-specification tilt of the M4 mirror. After correction,
two additional test campaigns were carried out, and we show that the shape of
the PSF is conform to expectations. The FWHM of the PSFs are 0.18-0.20 arcsec,
in agreement with simulations. 56.1-59.2% of the total encircled energy
(normalized to a 5 arcsec radius) is contained within the first dark Airy ring,
over the whole field of view. At longer wavelengths (7.7-25.5 microns), this
percentage is 57-68%. MIRIM is thus compliant with the optical quality
requirements. This characterization of the MIRIM PSF, as well as the
deconvolution method presented here, are of particular importance, not only for
the verification of the optical quality and the MIRI calibration, but also for
scientific applications.Comment: 13 pages, submitted to SPIE Proceedings vol. 7731, Space Telescopes
and Instrumentation 2010: Optical, Infrared, and Millimeter Wav
The Mid-Infrared Instrument for the James Webb Space Telescope, III: MIRIM, The MIRI Imager
In this article, we describe the MIRI Imager module (MIRIM), which provides
broad-band imaging in the 5 - 27 microns wavelength range for the James Webb
Space Telescope. The imager has a 0"11 pixel scale and a total unobstructed
view of 74"x113". The remainder of its nominal 113"x113" field is occupied by
the coronagraphs and the low resolution spectrometer. We present the instrument
optical and mechanical design. We show that the test data, as measured during
the test campaigns undertaken at CEA-Saclay, at the Rutherford Appleton
Laboratory, and at the NASA Goddard Space Flight Center, indicate that the
instrument complies with its design requirements and goals. We also discuss the
operational requirements (multiple dithers and exposures) needed for optimal
scientific utilization of the MIRIM.Comment: 29 pages, 9 figure
Dust in the inner regions of debris disks around A stars
We present infrared interferometric observations of the inner regions of two
A-star debris disks, beta Leo and zeta Lep, using the FLUOR instrument at the
CHARA interferometer on both short (30 m) and long (>200 m) baselines. For the
target stars, the short baseline visibilities are lower than expected for the
stellar photosphere alone, while those of a check star, delta Leo, are not. We
interpret this visibility offset of a few percent as a near-infrared excess
arising from dust grains which, due to the instrumental field of view, must be
located within several AU of the central star. For beta Leo, the near-infrared
excess producing grains are spatially distinct from the dust which produces the
previously known mid-infrared excess. For zeta Lep, the near-infrared excess
may be spatially associated with the mid-infrared excess producing material. We
present simple geometric models which are consistent with the near and
mid-infrared excess and show that for both objects, the near-infrared producing
material is most consistent with a thin ring of dust near the sublimation
radius with typical grain sizes smaller than the nominal radiation pressure
blowout radius. Finally, we discuss possible origins of the near-infrared
emitting dust in the context of debris disk evolution models.Comment: 20 pages, 2 figures, to appear in the Astrophysical Journa
The MIRI Medium Resolution Spectrometer calibration pipeline
The Mid-Infrared Instrument (MIRI) Medium Resolution Spectrometer (MRS) is
the only mid-IR Integral Field Spectrometer on board James Webb Space
Telescope. The complexity of the MRS requires a very specialized pipeline, with
some specific steps not present in other pipelines of JWST instruments, such as
fringe corrections and wavelength offsets, with different algorithms for point
source or extended source data. The MRS pipeline has also two different
variants: the baseline pipeline, optimized for most foreseen science cases, and
the optimal pipeline, where extra steps will be needed for specific science
cases. This paper provides a comprehensive description of the MRS Calibration
Pipeline from uncalibrated slope images to final scientific products, with
brief descriptions of its algorithms, input and output data, and the accessory
data and calibration data products necessary to run the pipeline.Comment: 10 pages, 8 figure
JWST/MIRI coronagraphic performances as measured on-sky
Characterization of directly imaged exoplanets is one of the most eagerly
anticipated science functions of the James Webb Space Telescope. MIRI, the
mid-IR instrument has the capability to provide unique spatially resolved
photometric data points in a spectral range never achieved so far for such
objects. We aim to present the very first on-sky contrast measurements of the
MIRI's coronagraphs. In addition to a classical Lyot coronagraph at the longest
wavelength, this observing mode implements the concept of the four quadrant
phase mask for the very first time in a space telescope. We observed single
stars together with a series of reference stars to measure raw contrasts as
they are delivered on the detector, as well as reference subtracted contrasts.
MIRI's coronagraphs achieve raw contrasts greater than at the smallest
angular separations (within ) and about further out (beyond
). Subtracting the residual diffracted light left unattenuated by the
coronagraph has the potential to bring the final contrast down to the
background and detector limited noise floor at most angular separations (a few
times at less than ). MIRI coronagraphs behave as expected from
simulations. In particular the raw contrasts for all four coronagraphs are
fully consistent with the diffractive model. Contrasts obtained with
subtracting reference stars also meet expectations and are fully demonstrated
for two four quadrant phase masks (F1065C and F1140C). The worst contrast,
measured at F1550C, is very likely due to a variation of the phase aberrations
at the primary mirror during the observations, and not an issue of the
coronagraph itself. We did not perform reference star subtraction with the Lyot
mask at F2300C, but we anticipate that it would bring the contrast down to the
noise floor.Comment: submitted to A&
JWST MIRI/MRS in-flight absolute flux calibration and tailored fringe correction for unresolved sources
Context. The Medium Resolution Spectrometer (MRS) is one of the four observing modes of JWST/MIRI. Using JWST in-flight data of unresolved (point) sources, we can derive the MRS absolute spectral response function (ASRF) starting from raw data. Spectral fringing, caused by coherent reflections inside the detector arrays, plays a critical role in the derivation and interpretation of the MRS ASRF. The fringe corrections implemented in the current pipeline are not optimal for non-extended sources, and a high density of molecular features particularly inhibits an accurate correction. Aims. In this paper, we present an alternative way to calibrate the MIRI/MRS data. Firstly, we derive a fringe correction that accounts for the dependence of the fringe properties on the MIRI/MRS pupil illumination and detector pixel sampling of the point spread function. Secondly, we derive the MRS ASRF using an absolute flux calibrator observed across the full 5- 28 \ub5m wavelength range of the MRS. Thirdly, we apply the new ASRF to the spectrum of a G dwarf and compare it with the output of the JWST/MIRI default data reduction pipeline. Finally, we examine the impact of the different fringe corrections on the detectability of molecular features in the G dwarf and K giant. Methods. The absolute flux calibrator HD 163466 (A-star) was used to derive tailored point source fringe flats at each of the default dither locations of the MRS. The fringe-corrected point source integrated spectrum of HD 163466 was used to derive the MRS ASRF using a theoretical model for the stellar continuum. A cross-correlation was run to quantify the uncertainty on the detection of CO, SiO, and OH in the K giant and CO in the G dwarf for different fringe corrections. Results. The point-source-tailored fringe correction and ASRF are found to perform at the same level as the current corrections, beating down the fringe contrast to the sub-percent level in the G dwarf in the longer wavelengths, whilst mitigating the alteration of real molecular features. The same tailored solutions can be applied to other MRS unresolved targets. Target acquisition is required to ensure the pointing is accurate enough to apply this method. A pointing repeatability issue in the MRS limits the effectiveness of the tailored fringe flats is at short wavelengths. Finally, resulting spectra require no scaling to make the sub-bands match, and a dichroic spectral leak at 12.2 \ub5m is removed
Spectroscopic time series performance of the Mid-Infrared Instrument on the JWST
We present here the first ever mid-infrared spectroscopic time series
observation of the transiting exoplanet \object{L 168-9 b} with the
Mid-Infrared Instrument (MIRI) on the James Webb Space Telescope. The data were
obtained as part of the MIRI commissioning activities, to characterize the
performance of the Low Resolution Spectroscopy (LRS) mode for these challenging
observations. To assess the MIRI LRS performance, we performed two independent
analyses of the data. We find that with a single transit observation we reached
a spectro-photometric precision of 50 ppm in the 7-8 \micron range at
R=50, consistent with 25 ppm systematic noise. The derived band averaged
transit depth is 524 15 ppm and 547 13 ppm for the two applied
analysis methods, respectively, recovering the known transit depth to within 1
. The measured noise in the planet's transmission spectrum is
approximately 15-20 \% higher than random noise simulations over wavelengths
m. \added{We observed an larger excess
noise at the shortest wavelengths of up to a factor of two, for which possible
causes are discussed.} This performance was achieved with limited in-flight
calibration data, demonstrating the future potential of MIRI for the
characterization of exoplanet atmospheres.Comment: Accepted for publishing in PASP, 21 pages, 10 figure
The mid-infrared instrument for the James Webb Space Telescope: performance and operation of the Low-Resolution Spectrometer
We describe here the performance and operational concept for the Low Resolution Spectrometer (LRS) of the mid-infrared instrument (MIRI) for the James Webb Space Telescope. The LRS will provide R∼100 slit and slitless spectroscopy from 5 to 12 micron, and its design is optimised for observations of compact sources, such as exoplanet host stars. We provide here an overview of the design of the LRS, and its performance as measured during extensive test campaigns, examining in particular the delivered image quality, dispersion, and resolving power, as well as spectrophotometric performance. The instrument also includes a slitless spectroscopy mode, which is optimally suited for transit spectroscopy of exoplanet atmospheres. We provide an overview of the operational procedures and the differences ahead of the JWST launch in 2018
Calibrating the James Webb Space telescope filters as star formation rate indicators
We have calibrated the 6.5m James Webb Space Telescope (JWST) mid-infrared (MIR) filters as star formation rate
(SFR) indicators, using JWST photometry synthesized from Spitzer spectra of 49 low-redshift galaxies, which cover a
wider luminosity range than most previous studies. We use Balmer-decrement-corrected Hα luminosity and
synthesized MIR photometry to empirically calibrate the Spitzer, WISE, and JWST filters as SFR indicators. Our
Spitzer and WISE calibrations are in good agreement with recent calibrations from the literature. While MIR
luminosity may be directly proportional to SFR for high-luminosity galaxies, we find a power-law relationship
between MIR luminosity and SFR for low-luminosity galaxies. We find that for galaxies with
an Hα luminosity of 1040 erg s-1 (corresponding to an SFR of~0.055 M yr-1), the corresponding JWST MIR ν Lν
luminosity is between 1040.50 and 1041.00 erg s-1. Power-law fits of JWST luminosity as a function of Hα luminosity
have indices between 1.17 and 1.32. We find that the scatter in the JWST filter calibrations decreases with increasing
wavelength from 0.39 to 0.20 dex, although F1000W is an exception where the scatter is just 0.24 dex
- …