128 research outputs found
Standard Methods for Bolt-Bearing Testing of Textile Composites
The response of three 2-D braided materials to bolt bearing loading was evaluated using data generated by Boeing Defense and Space Group in Philadelphia, PA. Three test methods, stabilized single shear, unstabilized single shear, and double shear, were compared. In general, these textile composites were found to be sensitive to bolt bearing test methods. The stabilized single shear method yielded higher strengths than the unstabilized single shear method in all cases. The double shear test method always produced the highest strengths but these results may be somewhat misleading. It is therefore recommended that standard material comparisons be made using the stabilized single shear test method. The effects of two geometric parameters, W/D and e/D, were also studied. An evaluation of the effect of the specimen width (W) to hole diameter (D) ratio concluded that bolt bearing responses were consistent with open hole tension results. A W/D ratio of 6 or greater should be maintained. The proximity of the hole to the specimen edge significantly affected strength. In all cases, strength was improved by increasing the ratio of the distance from the hole center to the specimen edge (e) to the hole diameter (D) above 2. An e/D ratio of 3 or greater is recommended
Standard methods for filled hole tension testing of textile composites
The effects of two test specimen geometry parameters, the specimen width and W/D ratio, on filled-hole tensile strength were determined for textile composite materials. Test data generated by Boeing and Lockheed on 2-D and 3-D braids, and 3-D weaves were used to make these evaluations. The investigation indicated that filled-hole tensile-strength showed little sensitivity to either parameter. Test specimen configurations used in open-hole tension tests, such as those suggested by ASTM D5766 - Standard Test Method for Open Hole Tensile Strength of Polymer Matrix Composite Laminates or those proposed by MIL-HDBK-17-lD should provide adequate results for material comparisons studies. Comparisons of the materials' open-hole and filled-hole tensile strengths indicated that the latter were generally lower than the former. The 3-D braids were the exception; their filled-hole strengths were unexpected larger than their open-hole strengths. However, these increases were small compared to the scatter in the data. Thus, filled hole tension may be a critical design consideration for textile composite materials
Standard methods for open hole tension testing of textile composites
Sizing effects have been investigated by comparing the open hole failure strengths of each of the four different braided architectures as a function of specimen thickness, hole diameter, and the ratio of specimen width to hole diameter. The data used to make these comparisons was primarily generated by Boeing. Direct comparisons of Boeing's results were made with experiments conducted at West Virginia University whenever possible. Indirect comparisons were made with test results for other 2-D braids and 3-D weaves tested by Boeing and Lockheed. In general, failure strength was found to decrease with increasing plate thickness, increase with decreasing hole size, and decreasing with decreasing width to diameter ratio. The interpretation of the sensitive to each of these geometrical parameters was complicated by scatter in the test data. For open hole tension testing of textile composites, the use of standard testing practices employed by industry, such as ASTM D5766 - Standard Test Method for Open Hole Tensile Strength of Polymer Matrix Composite Laminates should provide adequate results for material comparisons studies
Critical evaluation of stability constants for alpha-hydroxycarboxylic acid complexes with protons and metal ions and the accompanying enthalpy changes. Part II. Aliphatic 2-hydroxycarboxylic acids (IUPAC Technical Report)
Abstract
Stability constants for different aliphatic 2-hydroxycarboxylic acid complexes in aqueous solutions with protons and metal ions published between 1960 and the end of 1994 have been critically evaluated
Comparison of impact results for several polymeric composites over a wide range of low impact velocities
Static indentation, falling weight, and ballistic impact tests were conducted in clamped plates made of AS4/3501-6 and IM7/8551-7 prepreg tape. The transversely isotropic plates were nominally 7-mm thick. Pendulum and ballistic tests were also conducted on simply supported plates braided with Celion 12000 fibers and 3501-6 epoxy. The 20 degree braided plates were about 5-mm thick. The impactors had spherical or hemispherical shapes with a 12.7 mm diameter. Residual compression strength and damage size were measured. For a given kinetic energy, damage size was least for IM7/8551-7 and greatest for the braided material. Strengths varied inversely with damage size. For a given damage size, strength loss as a fraction of original strength was least for the braided material and greatest for AS4/3501-6 and IM7/8551-7. Strength loss for IM7/8551-7 and AS4/3501-6 was nearly equal. No significant differences were noticed between damage sizes and residual compression strengths for the static indentation, falling weight, and ballistic tests of AS4/3501-6 and IM7/8551-7. For the braided material, sizes of damage were significantly less and compression strengths were significantly more for the falling weight tests than for the ballistic tests
Neonatal intensive care parent satisfaction: a multicenter study translating and validating the Italian EMPATHIC-N questionnaire
Background: In Neonatal Intensive Care Units (NICUs), parent satisfaction and their experiences are fundamental to assess clinical practice and improve the quality of care delivered to infants and parents. Recently, a specific instrument, the EMpowerment of PArents in THe Intensive Care-Neonatology (EMPATHIC-N), has been developed in the Netherlands. This instrument investigated different domains of care in NICUs from a family-centered care perspective. In Italy, no rigorous instruments are available to evaluate parent satisfaction and experiences in NICU with family-centered care. The aim of this study was to translate and validate the EMPATHIC-N instrument into Italian language measuring parent satisfaction. Methods: A psychometric study was conducted in nine Italian NICUs. The hospitals were allocated across Italy: four in the North, four in Central region, one in the South. Parents whose infants were discharged from the Units were enrolled. Parents whose infants died were excluded. Results: Back-forward translation was conducted. Twelve parents reviewed the instrument to assess the cultural adaptation; none of the items fell below the cut-off of 80% agreement. A total of 186 parents of infants who were discharged from nine NICUs were invited to participate and 162 parents responded and returned the questionnaire (87%). The mean scores of the individual items varied between 4.3 and 5.9. Confirmatory factor analysis was performed and all factor loadings were statistically significant with the exception of item ‘Our cultural background was taken into account’. The items related to overall satisfaction showed a higher trend with mean values of 5.8 and 5.9. The Cronbach’s alpha’s (at domain level 0.73-0.92) and corrected item-total scale correlations revealed high reliability estimates. Conclusions: The Italian EMPATHIC-N showed to be a valid and reliable instrument measuring parent satisfaction in NICUs from a family-centered care perspective. Indeed, it had good psychometric properties, validity, and reliability. Furthermore, this instrument is fundamental for further research and internationally benchmarking
The new empiricism of the fractal fold: Rethinking monadology in digital times
A new configuration of social science is emerging in these digital times, as we tap into new kinds of data that trouble conventions regarding what constitutes the unit of analysis, and question the extent to which these data are owned or even correlated to a definitive organic and individuated subject customarily referred to as "human." These methodological shifts demand a more careful consideration of the historical lineage of empiricism and its relation to the history of science more generally. In this article, I track the historical mutations of monadology, an ontology well suited to empiricism in these digital times. Both Gilles Deleuze and Bruno Latour ascribe to variants of monadology in their proposals for a new empiricism, drawing extensively on the work of Gabriel Tarde (1843-1904), a French sociologist, judge, and author of the audacious post-humanist 1895 text Sociology and Monadology. In this article, I discuss how monadology helps us rethink research methods in these digital times. I argue that a fractal monadology re-assembles the fold with the digital, the continuous with the discrete, and ultimately offers a philosophical foundation for contemporary social science research
- …