35 research outputs found
Développement d'un outil informatique opérationnel d'aide à la décision et de modélisation des pollutions en Méditerranée
National audienc
Liver stiffness in nonalcoholic fatty liver disease: A comparison of supersonic shear imaging, FibroScan, and ARFI with liver biopsy
Nonalcoholic fatty liver disease (NAFLD) has become a major public health issue. The goal of this study was to assess the clinical use of liver stiffness measurement (LSM) evaluated by supersonic shear imaging (SSI), FibroScan, and acoustic radiation force impulse (ARFI) in a cohort of NAFLD patients who underwent liver biopsy. A total of 291 NAFLD patients were prospectively enrolled from November 2011 to February 2015 at 2 French university hospitals. LSM was assessed by SSI, FibroScan (M probe), and ARFI within two weeks prior to liver biopsy. Calculations of the area under the receiver operating curve (AUROC) were performed and compared for the staging of liver fibrosis. AUROC for SSI, FibroScan, and ARFI were 0.86, 0.82, and 0.77 for diagnoses of â„F2; 0.89, 0.86, and 0.84 for â„F3; and 0.88, 0.87, and 0.84 for F4, respectively. SSI had a higher accuracy than ARFI for diagnoses of significant fibrosis (â„F2) (P = 0.004). Clinical factors related to obesity such as body mass index â„ 30 kg/m(2) , waist circumference â„102 cm or increased parietal wall thickness were associated with LSM failures when using SSI or FibroScan and with unreliable results when using ARFI. In univariate analysis, FibroScan values were slightly correlated with NAFLD activity score and steatosis (R = 0.28 and 0.22, respectively), whereas SSI and ARFI were not; however, these components of NAFLD did not affect LSM results in multivariate analysis. The cutoff values for SSI and FibroScan for staging fibrosis with a sensitivity â„90% were very close: 6.3/6.2 kPa for â„F2, 8.3/8.2 kPa for â„F3, and 10.5/9.5 kPa for F4.
CONCLUSION: Although obesity is associated with an increase in LSM failure, the studied techniques and especially SSI provide high value for the diagnosis of liver fibrosis in NAFLD patients. (Hepatology 2016;63:1817-1827)
Criteria to Determine Reliability of Noninvasive Assessment of Liver Fibrosis With Virtual Touch Quantification
BACKGROUND & AIMS: Virtual Touch Quantification (VTQ) evaluates liver fibrosis in patients with chronic liver diseases by measuring shear wave speed in the liver. We aimed to determine the reliability criteria of VTQ examination.
METHODS: We performed a prospective study of 1094 patients with chronic liver disease from November 2009 through October 2016 at Angers University Hospital, and between April 2010 and May 2015 at Bordeaux University Hospital, in France. All patients underwent liver biopsy analysis (reference standard), and VTQ examination was made by experienced operators on the same day, or no more than 3 months before or afterward. Advanced liver fibrosis was defined as fibrosis stage F â„ 3 according to the scoring system of the Nonalcoholic Steatohepatitis Clinical Research Network, or fibrosis stage F â„ 2 according to the Metavir scoring system. The diagnostic accuracy of VTQ in detection of advanced fibrosis or cirrhosis was assessed using the area under the receiver operating characteristic (AUROC) and the rate of correctly classiïŹed patients. Reliability criteria were defined from the intrinsic characteristics of VTQ examination, which were shown to influence the diagnostic accuracy.
RESULTS: VTQ identified patients with advanced fibrosis with an AUROC of 0.773 ± 0.014 and correctly classified 72.0% of patients using a diagnostic cut-off value of 1.37 m/s. VTQ identified patients with cirrhosis with an AUROC value of 0.839 ± 0.014 and correctly classified 78.4% of patients using a cut-off value of 1.87 m/s. The reliability of VTQ decreased with an increasing ratio of interquartile range/median (IQR/M) in patients with intermediate-high VTQ results. We defined 3 reliability categories for VTQ: unreliable (IQR/M â„0.35 with VTQ result â„1.37 m/s), reliable (IQR/M â„0.35 with VTQ result <1.37 m/s or IQR/M 0.15-0.34), and very reliable (IQR/M <0.15). For advanced fibrosis, VTQ correctly classified 57.8% of patients in the unreliable group, 73.7% of patients in the reliable group, and 80.9% of patients in the very reliable group (P < .001); for cirrhosis, these values were 50.0%, 83.4%, and 92.6%, respectively (P < .001). Of the VTQ examinations made, 21.4% were unreliable, 55.0% were reliable, and 23.6% were very reliable. The skin-liver capsule distance was independently associated with an unreliable VTQ examination, which occurred in 52.7% of patients with a distance of 30 mm or more.
CONCLUSIONS: In a study to determine the reliability of VTQ findings, compared with results from biopsy analysis, we assigned VTQ examinations to 3 categories (unreliable, reliable, and very reliable). VTQ examinations with IQR/M â„0.35 and â„1.37 m/s had very low diagnostic accuracy. Our reliability criteria for liver fibrosis assessment with VTQ will help physicians to accurately evaluate the severity of chronic liver diseases and monitor their progression
Baculovirus Capsid Display Potentiates OVA Cytotoxic and Innate Immune Responses
Baculoviruses (BV) are DNA viruses that are pathogenic for insects. Although BV infect a range of mammalian cell types, they do not replicate in these cells. Indeed, the potential effects of these insect viruses on the immune responses of mammals are only just beginning to be studied. We show in this paper that a recombinant Autographa californica multiple nuclear polyhedrosis virus carrying a fragment of ovalbumin (OVA) on the VP39 capsid protein (BV-OVA) has the capacity to act as an adjuvant and vector of antigens in mice, thereby promoting specific CD4 and cytotoxic T cell responses against OVA. BV also induced in vivo maturation of dendritic cells and the production of inflammatory cytokines, thus promoting innate and adaptive immune responses. The OVA-specific response induced by BV-OVA was strong enough to reject a challenge with OVA-expressing melanoma cells (MO5 cells) and effectively prolonged survival of MO5 bearing mice. All these findings, together with the absence of pre-existing immunity to BV in humans and the lack of viral gene expression in mammalian cells, make BV a candidate for vaccination
A novel domain in histone deacetylase 1 and 2 mediates repression of cartilage-specific genes in human chondrocytes
The role of histone deacetylase 1 and 2 (HDAC1 and HDAC2) in regulating cartilage-specific gene expression was explored in primary human chondrocytes. HDAC1 and HDAC2 protein levels were elevated in chondrocytes from osteoarthritic patients, consistent with a down-regulation of some cartilage marker genes. When expressed in these cells, HDAC1 and HDAC2 repressed aggrecan and collagen 2(α1) expression but differed in their repression of collagen 9(α1), collagen 11(α1), dermatopontin, and cartilage oligomeric matrix protein (COMP). To identify the basis of these differences between HDAC1 and HDAC2, their carboxy-terminal domains (CTDs) were deleted, which led to proteins that retained enzymatic activity but were unable to repress cartilage gene expression. Further, exchange of the CTDs between HDAC1 and HDAC2 led to proteins that were enzymatically active but displayed altered target gene specificity, indicating that these CTDs can function independently of HDAC enzymatic activity, to target the HDACs to specific genes. The Snail transcription factor was identified as a mediator of HDAC1 and HDAC2 repression of the collagen 2(α1) gene, via its interaction with the HDAC1 and 2 CTDs. The data indicate that the CTD serves a novel function within HDAC1 and HDAC2, to mediate repression of cartilage-specific gene expression in human chondrocytes.âHong, S., Derfoul, A., Pereira-Mouries, L., Hall, D. J. A novel domain in histone deacetylase 1 and 2 mediates repression of cartilage-specific genes in human chondrocytes
Développement d'un outil informatique opérationnel d'aide à la décision et de modélisation des pollutions en Méditerranée
National audienc