231 research outputs found

    Robust NMR water signal suppression for demanding analytical applications

    Get PDF
    We describe the design and application of robust, general-purpose water signal suppression pulse sequences well suited to chemometric work. Such pulse sequences need to deal well with pulse mis-calibrations, radiation damping, chemical exchange, and the presence of sample inhomogeneities, as well as with significant variations in sample characteristics such as pH, ionic strength, relaxation characteristics and molecular weight. Of course, such pulse sequences should produce un-distorted lineshapes and baselines and work well both under automation and in the hands of non-experts. As an example, one such pulse sequences, Robust-5, will be presented. This new pulse sequence meets those criteria and is able to reduce a 50 M proteo water signal down to a 0.9 mM level, without fine tuning, and under automation, and it is therefore well suited to the most demanding of analytical applications

    Extraction and Visualization of Swirl and Tumble Motion from Engine Simulation Data

    Get PDF
    Figure 1: Unsteady visualization of vortices from in-cylinder tumble motion in a gas engine and its relationship to the boundary. During the valve cycle (left to right), the piston head that shapes the bottom of the geometry moves down (not shown). The volume rendering shows vortices using a two-dimensional transfer function of λ2 and normalized helicity (legend). The main tumble vortex is extracted and visible as off-center and with an undesired diagonal orientation. The flow structure on the boundary is visualized using boundary topology. A direct correspondence between the volume and boundary visualizations can be observed. In the third image, the intersection of the main vortex with the boundary results in critical points on the front and back walls. Optimizing the combustion process within an engine block is central to the performance of many motorized vehicles. Associated with this process are two important patterns of flow: swirl and tumble motion, which optimize the mixing of fluid within each of an engine’s cylinders. Good visualizations are necessary to analyze the simulation data of these in-cylinder flows. We present a range of methods including integral, feature-based, and imagebased schemes with the goal of extracting and visualizing these tw

    Using remote substituents to control solution structure and anion binding in lanthanide complexes.

    Get PDF
    A study of the anion-binding properties of three structurally related lanthanide complexes, which all contain chemically identical anion-binding motifs, has revealed dramatic differences in their anion affinity. These arise as a consequence of changes in the substitution pattern on the periphery of the molecule, at a substantial distance from the binding pocket. Herein, we explore these remote substituent effects and explain the observed behaviour through discussion of the way in which remote substituents can influence and control the global structure of a molecule through their demands upon conformational space. Peripheral modifications to a binuclear lanthanide motif derived from α,α′-bis(DO3 Ayl)-m-xylene are shown to result in dramatic changes to the binding constant for isophthalate. In this system, the parent compound displays considerable conformational flexibility, yet can be assumed to bind to isophthalate through a well-defined conformer. Addition of steric bulk remote from the binding site restricts conformational mobility, giving rise to an increase in binding constant on entropic grounds as long as the ideal binding conformation is not excluded from the available range of conformers

    In vivo measurement of bending stiffness in fracture healing

    Get PDF
    BACKGROUND: Measurement of the bending stiffness a healing fracture represents a valid variable in the assessment of fracture healing. However, currently available methods typically have high measurement errors, even for mild pin loosening. Furthermore, these methods cannot provide actual values of bending stiffness, which precludes comparisons among individual fractures. Thus, even today, little information is available with regards to the fracture healing pattern with respect to actual values of bending stiffness. Our goals were, therefore: to develop a measurement device that would allow accurate and sensitive measurement of bending stiffness, even in the presence of mild pin loosening; to describe the course of healing in individual fractures; and help to evaluate whether the individual pattern of bending stiffness can be predicted at an early stage of healing. METHODS: A new measurement device has been developed to precisely measure the bending stiffness of the healing fracture by simulating four-point-bending. The system was calibrated on aluminum models and intact tibiae. The influence of pin loosening on measurement error was evaluated. The system was tested at weekly intervals in an animal experiment to determine the actual bending stiffness of the fracture. Transverse fractures were created in the right tibia of twelve sheep, and then stabilized with an external fixator. At ten weeks, bending stiffness of the tibiae were determined in a four-point-bending test device to validate the in-vivo-measurement data. RESULTS: In-vivo bending stiffness can be measured accurately and sensitive, even in the early phase of callus healing. Up to a bending stiffness of 10 Nm/degree, measurement error was below 3.4% for one pin loose, and below 29.3% for four pins loose, respectively. Measurement of stiffness data over time revealed a significant logarithmic increase between the third and seventh weeks, whereby the logarithmic rate of change among sheep was similar, but started from different levels. Comparative measurements showed that early individual changes between the third and fourth weeks can be used as a predictor of bending stiffness at seven weeks (r = 0.928) and at ten weeks (r = 0.710). CONCLUSION: Bending stiffness can be measured precisely, with less error in the case of pin loosening. Prediction of the future healing course of the individual fracture can be assessed by changes from the third to the fourth week, with differences in stiffness levels. Therefore, the initial status of the fracture seems to have a high impact on the individual healing course

    A protocol for improved measurement of arterial flow rate in preclinical ultrasound

    Get PDF
    PURPOSE: To describe a protocol for the measurement of blood flow rate in small animals and to compare flow rate measurements against measurements made using a transit time flowmeter. MATERIALS AND METHODS: Measurements were made in rat and mice using a Visualsonics Vevo 770 scanner. The flow rate in carotid and femoral arteries was calculated from the time-average maximum velocity and vessel diameter. A correction factor was applied to correct for the overestimation of velocity arising from geometric spectral broadening. Invasive flow rate measurements were made using a Transonics system. RESULTS: Measurements were achieved in rat carotid and femoral arteries and in mouse carotid arteries. Image quality in the mouse femoral artery was too poor to obtain diameter measurements. The applied correction factor in practice was 0.71–0.77. The diameter varied by 6–18% during the cardiac cycle. There was no overall difference in the flow rate measured using ultrasound and using transit-time flowmeters. The flow rates were comparable with those previously reported in the literature. There was wide variation in flow rates in the same artery in individual animals. Transit-time measurements were associated with changes of a factor of 10 during the typical 40 min measurement period, associated with probe movement, vessel spasm, vessel kinking and other effects. CONCLUSION: A protocol for the measurement of flow rate in arteries in small animals has been described and successfully used in rat carotid and femoral arteries and in mouse carotid arteries. The availability of a noninvasive procedure for flow rate measurement avoids the problems with changes in flow associated with an invasive procedure

    Using Remote Substituents to Control Solution Structure and Anion Binding in Lanthanide Complexes

    Get PDF
    A study of the anion-binding properties of three structurally related lanthanide complexes, which all contain chemically identical anion-binding motifs, has revealed dramatic differences in their anion affinity. These arise as a consequence of changes in the substitution pattern on the periphery of the molecule, at a substantial distance from the binding pocket. Herein, we explore these remote substituent effects and explain the observed behaviour through discussion of the way in which remote substituents can influence and control the global structure of a molecule through their demands upon conformational space. Peripheral modifications to a binuclear lanthanide motif derived from α,α′-bis(DO3 Ayl)-m-xylene are shown to result in dramatic changes to the binding constant for isophthalate. In this system, the parent compound displays considerable conformational flexibility, yet can be assumed to bind to isophthalate through a well-defined conformer. Addition of steric bulk remote from the binding site restricts conformational mobility, giving rise to an increase in binding constant on entropic grounds as long as the ideal binding conformation is not excluded from the available range of conformers

    Benzoate dioxygenase from<em> Ralstonia eutropha</em> B9 – unusual regiochemistry of dihydroxylation permits rapid access to novel chirons

    Get PDF
    Oxidation of benzoic acid by a microorganism expressing benzoate dioxygenase leads to the formation of an unusualipso,orthoarenecis-diol in sufficient quantities to be useful for synthesis.</p

    Accelerated tibial fracture union in the third trimester of pregnancy: a case report

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>We present a case of accelerated tibial fracture union in the third trimester of pregnancy. This is of particular relevance to orthopaedic surgeons, who must be made aware of the potentially accelerated healing response in pregnancy and the requirement for prompt treatment.</p> <p>Case presentation</p> <p>A 40 year old woman at 34 weeks gestational age sustained a displaced fracture of the tibial shaft. This was initially treated conservatively in plaster with view to intra-medullary nailing postpartum. Following an emergency caesarean section, the patient was able to fully weight bear without pain 4 weeks post injury, indicating clinical union. Radiographs demonstrated radiological union with good alignment and abundant callus formation. Fracture union occurred within 4 weeks, less than half the time expected for a conservatively treated tibial shaft fracture.</p> <p>Conclusion</p> <p>Long bone fractures in pregnancy require clear and precise management plans as fracture healing is potentially accelerated. Non-operative treatment is advisable provided satisfactory alignment of the fracture is achieved.</p

    The discriminatory value of cardiorespiratory interactions in distinguishing awake from anaesthetised states: a randomised observational study

    Get PDF
    Depth of anaesthesia monitors usually analyse cerebral function with or without other physiological signals; noninvasive monitoring of the measured cardiorespiratory signals alone would offer a simple, practical alternative. We aimed to investigate whether such signals, analysed with novel, non-linear dynamic methods, would distinguish between the awake and anaesthetised states. We recorded ECG, respiration, skin temperature, pulse and skin conductivity before and during general anaesthesia in 27 subjects in good cardiovascular health, randomly allocated to receive propofol or sevoflurane. Mean values, variability and dynamic interactions were determined. Respiratory rate (p = 0.0002), skin conductivity (p = 0.03) and skin temperature (p = 0.00006) changed with sevoflurane, and skin temperature (p = 0.0005) with propofol. Pulse transit time increased by 17% with sevoflurane (p = 0.02) and 11% with propofol (p = 0.007). Sevoflurane reduced the wavelet energy of heart (p = 0.0004) and respiratory (p = 0.02) rate variability at all frequencies, whereas propofol decreased only the heart rate variability below 0.021 Hz (p < 0.05). The phase coherence was reduced by both agents at frequencies below 0.145 Hz (p < 0.05), whereas the cardiorespiratory synchronisation time was increased (p < 0.05). A classification analysis based on an optimal set of discriminatory parameters distinguished with 95% success between the awake and anaesthetised states. We suggest that these results can contribute to the design of new monitors of anaesthetic depth based on cardiovascular signals alone
    • …