156 research outputs found

    Feasibility and acceptability of implementing early infant diagnosis of HIV in Papua New Guinea at the point of care: a qualitative exploration of health worker and key informant perspectives

    Get PDF
    Introduction: Early infant diagnosis (EID) of HIV and timely initiation of antiretroviral therapy can significantly reduce morbidity and mortality among HIV-positive infants. Access to EID is limited in many low-income and middle-income settings, particularly those in which standard care involves dried blood spots (DBS) sent to centralised laboratories, such as in Papua New Guinea (PNG). We conducted a qualitative exploration of the feasibility and acceptability of implementing a point-of-care (POC) EID test (Xpert HIV-1 Qualitative assay) among health workers and key stakeholders working within the prevention of mother-to-child transmission of HIV (PMTCT) programme in PNG. Methods: This qualitative substudy was conducted as part of a pragmatic trial to investigate the effectiveness of the Xpert HIV-1 Qualitative test for EID in PNG and Myanmar. Semistructured interviews were undertaken with 5 health workers and 13 key informants to explore current services, experiences of EID testing, perspectives on the Xpert test and the feasibility of integrating and scaling up POC EID in PNG. Coding was undertaken using inductive and deductive approaches, drawing on existing acceptability and feasibility frameworks. Results: Health workers and key informants (N=18) felt EID at POC was feasible to implement and beneficial to HIV-exposed infants and their families, staff and the PMTCT programme more broadly. All study participants highlighted starting HIV-positive infants on treatment immediately as the main advantage of POC EID compared with standard care DBS testing. Health workers identified insufficient resources to follow up infants and caregivers and space constraints in hospitals as barriers to implementation. Participants emphasised the importance of adequate human resources, ongoing training and support, appropriate coordination and a sustainable supply of consumables to ensure effective scale-up of the test throughout PNG. Conclusions: Implementation of POC EID in a low HIV prevalence setting such as PNG is likely to be both feasible and beneficial with careful planning and adequate resources

    Understanding barriers and outcomes of unspecified (non-directed altruistic) kidney donation from both professional's and patient's perspectives: research protocol for a national multicentre mixed-methods prospective cohort study.

    Get PDF
    INTRODUCTION: Living donation accounts for over one-third of all kidney transplants taking place in the UK. 1 The concept of anonymously donating a kidney to a stranger (non-directed altruistic or unspecified kidney donation (UKD)) remains uncomfortable for some clinicians, principally due to concerns about the motivations and long-term physical and psychological outcomes in this donor group. AIMS: The research programme aims to provide a comprehensive assessment of the unspecified donor programme in the UK. It aims to identify reasons for variations in practice across centres, explore outcomes for donors and ascertain barriers and facilitators to UKD, as well as assess the economic implications of unspecified donation. METHODS: The research programme will adopt a mixed-methods approach to assessing UKD nationally using focus groups, interviews and questionnaires. Two study populations will be investigated. The first will include transplant professionals involved in unspecified kidney donation. The second will include a 5-year prospective cohort of individuals who present to any of the 23 UK transplant centres as a potential unspecified living kidney donor. Physical and psychological outcomes will be followed up to 1 year following donation or withdrawal from the donation process. A matched sample of specified donors (those donating to someone they know) will be recruited as a control group. Further qualitative work consisting of interviews will be performed on a purposive sample of unspecified donors from both groups (those who do and do not donate). DISSEMINATION: The findings will be reported to NHS Blood and Transplant and the British Transplant Society with a view to developing national guidelines and a protocol for the management of those presenting for unspecified donation. TRIAL REGISTRATION NUMBER: ISRCTN23895878, Pre-results

    Analytic philosophy for biomedical research: the imperative of applying yesterday's timeless messages to today's impasses

    Get PDF
    The mantra that "the best way to predict the future is to invent it" (attributed to the computer scientist Alan Kay) exemplifies some of the expectations from the technical and innovative sides of biomedical research at present. However, for technical advancements to make real impacts both on patient health and genuine scientific understanding, quite a number of lingering challenges facing the entire spectrum from protein biology all the way to randomized controlled trials should start to be overcome. The proposal in this chapter is that philosophy is essential in this process. By reviewing select examples from the history of science and philosophy, disciplines which were indistinguishable until the mid-nineteenth century, I argue that progress toward the many impasses in biomedicine can be achieved by emphasizing theoretical work (in the true sense of the word 'theory') as a vital foundation for experimental biology. Furthermore, a philosophical biology program that could provide a framework for theoretical investigations is outlined

    A longitudinal, multi-level comparative study of quality and safety in European hospitals: the QUASER study protocol

    Get PDF
    although there is a wealth of information available about quality improvement tools and techniques in healthcare there is little understanding about overcoming the challenges of day-to-day implementation in complex organisations like hospitals. The 'Quality and Safety in Europe by Research' (QUASER) study will investigate how hospitals implement, spread and sustain quality improvement, including the difficulties they face and how they overcome them. The overall aim of the study is to explore relationships between the organisational and cultural characteristics of hospitals and how these impact on the quality of health care; the findings will be designed to help policy makers, payers and hospital managers understand the factors and processes that enable hospitals in Europe to achieve-and sustain-high quality services for their patients

    Gaia Data Release 2: Calibration and mitigation of electronic offset effects in the data

    Get PDF
    The European Space Agency Gaia satellite was launched into orbit around L2 in December 2013. This ambitious mission has strict requirements on residual systematic errors resulting from instrumental corrections in order to meet a design goal of sub-10 microarcsecond astrometry. During the design and build phase of the science instruments, various critical calibrations were studied in detail to ensure that this goal could be met in orbit. In particular, it was determined that the video-chain offsets on the analogue side of the analogue-to-digital conversion electronics exhibited instabilities that could not be mitigated fully by modifications to the flight hardware. We provide a detailed description of the behaviour of the electronic offset levels on microsecond timescales, identifying various systematic effects that are known collectively as offset non-uniformities. The effects manifest themselves as transient perturbations on the gross zero-point electronic offset level that is routinely monitored as part of the overall calibration process. Using in-orbit special calibration sequences along with simple parametric models, we show how the effects can be calibrated, and how these calibrations are applied to the science data. While the calibration part of the process is relatively straightforward, the application of the calibrations during science data processing requires a detailed on-ground reconstruction of the readout timing of each charge-coupled device (CCD) sample on each device in order to predict correctly the highly time-dependent nature of the corrections. We demonstrate the effectiveness of our offset non-uniformity models in mitigating the effects in Gaia data. We demonstrate for all CCDs and operating instrument and modes on board Gaia that the video-chain noise-limited performance is recovered in the vast majority of science samples

    Investigation into the cause of spontaneous emulsification of a free steel droplet : validation of the chemical exchange pathway

    Get PDF
    Small Fe-based droplets have been heated to a molten phase suspended within a slag medium to replicate a partial environment within the basic oxygen furnace (BOF). The confocal scanning laser microscope (CSLM) has been used as a heating platform to interrogate the effect of impurities and their transfer across the metal/slag interface, on the emulsification of the droplet into the slag medium. The samples were then examined through X-ray computer tomography (XCT) giving the mapping of emulsion dispersion in 3D space, calculating the changing of interfacial area between the two materials, and changes of material volume due to material transfer between metal and slag. Null experiments to rule out thermal gradients being the cause of emulsification have been conducted as well as replication of the previously reported study by Assis et al.[1] which has given insights into the mechanism of emulsification. Finally chemical analysis was conducted to discover the transfer of oxygen to be the cause of emulsification, leading to a new study of a system with undergoing oxygen equilibration

    Health-related quality-of-life measures for long-term follow-up in children after major trauma

    Get PDF
    Objective: Our objective was to review measures of health-related quality of life (HRQL) for long-term follow up in children after major trauma and to determine the measures that are suitable for a large age range, reliable and valid, and cover a substantial amount of the domains of functioning using the International Classification of Functioning, Disability, and Health (ICF) of the World Health Organization (WHO). Methods: The Medline and EMBASE databases were searched in all years up to October 2007 for generic HRQL measures suitable for children aged 5-18 years old and validated in English or Dutch. Measures were reviewed with respect to the age range for which the measure was suitable and reliability, validity, and content related to the ICF. Results: The search resulted in 1,235 hits and 21 related articles. Seventy-nine papers met the inclusion criteria, describing in total 14 measures: Child Health and Illness Profile Adolescent and Child Edition (CHIP-AE/CE), Child Health Questionnaire Child and Parent Forms (CHQCF87/PF50/PF28), DISABKIDS, Functional Status II (FS II)(R), Health Utilities Index Mark 2 (HUI 2), KIDSCREEN 52/27, KINDL, Pediatric Quality of Life Inventory (PedsQL), TNO Institute of Prevention and Health and the Leiden University Hospital (TNO-AZL), TNO-AZL Children’s Quality Of Life (TACQOL), and Youth Quality of Life Instrument-Research Version (YQOL-R). Measures that were suitable for a large age range were CHQ-PF50/PF28, DISABKIDS, FS II(R), HUI 2, KIDSCREEN, PedsQL, and TACQOL. All measures had moderate to good psychometric properties, except for CHQ-PF50/PF28, KINDL, and TACQOL, which had either low internal consistency or bad test-retest reliability. The measures that covered more than six chapters of the ICF domains were CHIP-AE/CE, CHQ-CF87/PF50, DISABKIDS, KIDSCREEN-52, PedsQL, and TACQOL. Conclusions: DISABKIDS, KIDSCREEN 52, and Peds-QL are suitable for long-term follow-up measurement of HRQL in children after major trauma. They cover a large age range, have good psychometric properties, and cover the ICF substantially
    corecore