10 research outputs found

    Analyzing Trace Elements in the Structures of Glaucomatous Eyes

    Get PDF
    Trace elements (TE) were analyzed in sclera biopsy specimens, samples of anterior chamber aqueous humor, and tear fluid of 12 patients aged between 53 and 79 years with various stages of primary open-angle glaucoma (POAG), using an atomic absorption spectrometer AS-3, inductively coupled plasma-mass spectrometer ELAN 6100-ICP-MS (Perkin-Elmer), and a Thermo Scientific plasma spectrometer iCAP-7000 (USA). Detected irregularities in the content of some TE (magnesium, iron, zinc, etc.) in anterior chamber aqueous humor of POAG patients may be a serious pathogenetic factor that violates the viscosity, and hence, the hydrodynamics, of intraocular fluid. An imbalance of TE in the tissues and media of glaucomatous eyes can contribute to the development of glaucomatous damage

    A Pressure Sensor for an Electrode System in Transpalpebral Rheoophtalmography

    Get PDF
    A method of pressure registration in transpalpebral rheoophtalmography (TP-ROG) is proposed. Possible construction solutions of this method are presented, including sensor types and their technical parameters. One such solution (a resistive pressure sensor) was incorporated in a TP-ROG electrode system. The system was used to measure the sensitivity and linearity of this pressure sensor

    IMI : global trends in myopia management attitudes and strategies in clinical practice : 2022 update

    Get PDF
    PURPOSE. Surveys in 2015 and 2019 identified a high level of eye care practitioner concern/activity about myopia, but the majority still prescribed single vision interventions to young myopes. This research aimed to provide updated information. METHODS. A self-administered, internet-based questionnaire was distributed in 13 languages, through professional bodies to eye care practitioners globally. The questions examined awareness of increasing myopia prevalence, perceived efficacy and adoption of available strategies, and reasons for not adopting specific strategies. RESULTS. Of the 3195 respondents, practitioners’ concern about the increasing frequency of pediatric myopia in their practices differed between continents (P < 0.001), being significantly higher in Asia (9.0 ± 1.5 of 10) than other continents (range 7.7–8.2; P ≤ 0.001). Overall, combination therapy was perceived by practitioners to be the most effective method of myopia control, followed by orthokeratology and pharmaceutical approaches. The least effective perceived methods were single vision distance undercorrection, spectacles and contact lenses, as well as bifocal spectacles. Practitioners rated their activity in myopia control between (6.6 ± 2.9 in South America to 7.9 ± 1.2/2.2 in Australasia and Asia). Single-vision spectacles are still the most prescribed option for progressing young myopia (32.2%), but this has decreased since 2019, and myopia control spectacles (15.2%), myopia control contact lenses (8.7%) and combination therapy (4.0%) are growing in popularity. CONCLUSIONS. More practitioners across the globe are practicing myopia control, but there are still significant differences between and within continents. Practitioners reported that embracing myopia control enhanced patient loyalty, increasing practice revenue and improving job satisfaction

    Differences in Practitioner Experience, Practice Type, and Profession in Attitudes Toward Growing Contact Lens Practice

    Get PDF
    OBJECTIVE: To investigate eye care practitioners' attitudes and perceptions toward potential interventions that can enhance contact lens (CL) practice across the world, and how this is influenced by their practice setting. METHODS: A self-administered, anonymized survey was constructed in English and then forward and backward translated into six more languages. The survey was distributed online via social media platforms and mailing lists involving reputed international professional bodies. RESULTS: In total, 2,222 responses from 27 countries with sufficient responses were analyzed (53% females, median age- 37 years). Most of the respondents were optometrists (81.9%) and 47.6% were from stand-alone/independent practices. Median working experience in CL prescribing was 11.0 years (IQR: 18.0, 4-22 years). Over two-third of them declared themselves to be very hopeful (22.9%) or hopeful (45.1%) about the future of their CL practice. Among the potential interventions proposed, continuous update of knowledge and skills and competently managing CL-related complications were rated the most important (median score: 9/10 for each). Practitioners working in national/regional retail chains expressed higher proactivity in recommending CLs (9/10) than those in local chains, hospitals, and universities (for all 8/10, P <0.05). National differences were also identified in eye care practitioner attitudes and perceptions ( P <0.05). CONCLUSIONS: The study provided important information to delineate a variety of elements characterizing CL practice across the world. These insights can serve as a basis to design strategies at national and international levels

    Global trends in myopia management attitudes and strategies in clinical practice – 2019 Update

    Get PDF
    Purpose: A survey in 2015 identified a high level of eye care practitioner concern about myopia with a reported moderately high level of activity, but the vast majority still prescribed single vision interventions to young myopes. This research aimed to update these findings 4 years later. Methods: A self-administrated, internet-based questionnaire was distributed in eight languages, through professional bodies to eye care practitioners globally. The questions examined: awareness of increasing myopia prevalence, perceived efficacy of available strategies and adoption levels of such strategies, and reasons for not adopting specific strategies. Results: Of the 1336 respondents, concern was highest (9.0 ± 1.6; p < 0.001) in Asia and lowest (7.6 ± 2.2; p < 0.001) in Australasia. Practitioners from Asia also considered their clinical practice of myopia control to be the most active (7.7 ± 2.3; p < 0.001), the North American practitioners being the least active (6.3 ± 2.9; p < 0.001). Orthokeratology was perceived to be the most effective method of myopia control, followed by pharmaceutical approaches and approved myopia control soft contact lenses (p < 0.001). Although significant intra-regional differences existed, overall, most practitioners did not consider single-vision distance under-correction to be an effective strategy for attenuating myopia progression (79.6 %), but prescribed single vision spectacles or contact lenses as the primary mode of correction for myopic patients (63.6 ± 21.8 %). The main justifications for their reluctance to prescribe alternatives to single vision refractive corrections were increased cost (20.6 %) and inadequate information (17.6 %). Conclusions: While practitioner concern about myopia and the reported level of activity have increased over the last 4 years, the vast majority of eye care clinicians still prescribe single vision interventions to young myopes. With recent global consensus evidence-based guidelines having been published, it is hoped that this will inform the practice of myopia management in future

    The possibilities of pharmacological intervention in myopia

    Get PDF
    This paper presents and discusses the current possibilities of pharmacological intervention in myopia. A review ofthe latest literature regarding the pharmacological treatment of myopia has been presented. The results of experimental research on the potential use of: atropine, oxyphenonium, pirenzepine, chlorpyrifos,apomorphine, reserpine, 6-hydroxy dopamine, dextromethorphan, MK-801, APV, bicuculline, SR95531, CACA,TPMPA, dextrophanol, levorphanol, D- and L-naloxane, L-NAME, formoguanamine, b-xyloside, the central andperipheral antagonist of VIP, basic fibroblast growth factor, a solution of the basic amino acid salts in the form ofsuccinates, in the treatment of myopia have been described. The clinical use of pirenzepine,7-methylxanthine, andatropine has been discussed. The obtained results of experimental and clinical studies give hope that a new effective pharmacological method ofmyopia treatment can be discovered soon

    Effects of poly(2-hydroxyethyl methacrylate) and poly(vinyl-pyrrolidone) hydrogel implants on myopic and normal chick sclera

    No full text
    There has been generally little attention paid to the utilization of biomaterials as an anti-myopia treatment. The purpose of this study was to investigate whether polymeric hydrogels, either implanted or injected adjacent to the outer scleral surface, slow ocular elongation. White Leghorn (Gallus gallus domesticus) chicks were used at 2 weeks of age. Chicks had either (1) a strip of poly(2-hydroxyethyl methacrylate) (pHEMA) implanted monocularly against the outer sclera at the posterior pole, or (2) an in situ polymerizing gel [main ingredient: poly(vinyl-pyrrolidone) (PVP)] injected monocularly at the same location. Some of the eyes injected with the polymer were fitted with a diffuser or a -10D lens. In each experiment, ocular lengths were measured at regular intervals by high frequency A-scan ultrasonography, and chicks were sacrificed for histology at staged intervals. No in vivo signs of either orbital or ocular inflammation were observed. The pHEMA implant significantly increased scleral thickness by the third week, and the implant became encapsulated with fibrous tissue. The PVP-injected eyes left otherwise untreated, showed a significant increase in scleral thickness, due to increased chondrocyte proliferation and extracellular matrix deposition. However, there was no effect of the PVP injection on ocular elongation. In eyes wearing optical devices, there was no effect on either scleral thickness or ocular elongation. These results represent proof of principle that scleral growth can be manipulated without adverse inflammatory responses. However, since neither approach slowed ocular elongation, additional factors must influence scleral surface area expansion in the avian eye

    Applying Transpalpebral Rheoophthalmography to Monitor Effectiveness of the Treatment of Patients with Glaucoma

    No full text
    Assessment of ocular hemodynamics is an important element in diagnosis of all forms of glaucoma. Existing methods, unlike the transpalpebral rheoophthalmography (TP-ROG), evaluate only the posterior eye segment. This study evaluates the opportunities of new TP-ROG technology to assess the effectiveness of the glaucoma treatment. The proposed TP-ROG method is characterized by ease of use and the lack of direct contact between the surface of the eyeball and the electrodes; this method is highly informative and quite accurate, which allows us to objectively assess the state of ocular hemodynamics in patients with primary open-angle glaucoma

    Opportunities and threats to contact lens practice:A global survey perspective

    No full text
    Aim: To understand the views of contact lens (CL) practitioners across the globe regarding what they perceive as opportunities and threats in CL practice. Methods: A self-administered anonymised questionnaire, constructed in English and translated in six more languages, was distributed through reputed international professional bodies and academic institutions worldwide. The questionnaire included items on demographic characteristics, type of practice, and questions designed to explore practitioners’ perspective on the future of their CL practice over the next five years. Results: A total of 2408 valid responses were analysed. Multifocal CLs for presbyopia, CLs for myopia control, use of daily disposable (DD) CLs for occasional wear, and biocompatible materials to improve comfort were identified as promising areas of opportunities by practitioners (all 8/10). Respondents from North America, and Europe valued DDCLs for occasional wear moderately more favourable (Median: 9/10 for all) as compared to colleagues in Asia (Median: 8/10, p < 0.001), South America (Median: 8/10, p < 0.01), and Africa (Median: 8/10p < 0.01). Multifocal CLs for presbyopia was perceived as a better opportunity by practitioners in North America and Europe (Median: 9/10 for both), as well as in Australasia (Median: 8/10), in comparison to Asia, Africa, and Middle East (for all Median: 6/10, p < 0.001). Practitioners expressed concerns about the availability of CLs and CL prescriptions online without direct professional involvement (both 9/10). Conclusions: Overall, the most appealing opportunities for CL practice growth were identified in occasional use of DD CLs, biocompatible materials to reduce CL discomfort, multifocal CLs for presbyopia correction and management of myopia control with CLs. Lack of regulation in CL sales, especially online, seemed to be a constant threat. The insights from this study can be used to design targeted strategies to enhance CL practice across the globe and in specific geographical areas
    corecore