24 research outputs found

    Femtomolar detection of the heart failure biomarker NT-proBNP in artificial saliva using an immersible liquid-gated aptasensor with reduced graphene oxide

    Full text link
    Measuring NT-proBNP biomarker is recommended for preliminary diagnostics of the heart failure. Recent studies suggest a possibility of early screening of biomarkers in saliva for non-invasive identification of cardiac diseases at the point-of-care. However, NT-proBNP concentrations in saliva can be thousand time lower than in blood plasma, going down to pg/mL level. To reach this level, we developed a label-free aptasensor based on a liquid-gated field effect transistor using a film of reduced graphene oxide monolayer (rGO-FET) with immobilized NT-proBNP specific aptamer. We found that, depending on ionic strength of tested solutions, there were different levels of correlation in responses of electrical parameters of the rGO-FET aptasensor, namely, the Dirac point shift and transconductance change. The correlation in response to NT-proBNP was high for 1.6 mM phosphate-buffered saline (PBS) and zero for 16 mM PBS in a wide range of analyte concentrations, varied from 1 fg/mL to 10 ng/mL. The effects of transconductance and Dirac point shift in PBS solutions of different concentrations are discussed. The biosensor exhibited a high sensitivity for both transconductance (2 uS/decade) and Dirac point shift (2.3 mV/decade) in diluted PBS with the linear range from 10 fg/mL to 1 pg/mL. The aptasensor performance has been also demonstrated in undiluted artificial saliva with the achieved limit of detection down to 41 fg/mL (~4.6 fM)

    Advances in nanomaterials-based electrochemical biosensors for foodborne pathogen detection

    Get PDF
    Electrochemical biosensors utilizing nanomaterials have received widespread attention in pathogen detection and monitoring. Here, the potential of different nanomaterials and electrochemical technologies is reviewed for the development of novel diagnostic devices for the detection of foodborne pathogens and their biomarkers. The overview covers basic electrochemical methods and means for electrode functionalization, utilization of nanomaterials that include quantum dots, gold, silver and magnetic nanoparticles, carbon nanomaterials (carbon and graphene quantum dots, carbon nanotubes, graphene and reduced graphene oxide, graphene nanoplatelets, laser-induced gra-phene), metal oxides (nanoparticles, 2D and 3D nanostructures) and other 2D nanomaterials. More-over, the current and future landscape of synergic effects of nanocomposites combining different nanomaterials is provided to illustrate how the limitations of traditional technologies can be over-come to design rapid, ultrasensitive, specific and affordable biosensors

    Thermoelectrically Driven Photocurrent Generation in Femtosecond Laser Patterned Graphene Junctions

    No full text
    Single and few-layer graphene photodetectors have attracted much attention in the past few years. Pristine graphene shows a very weak response to visible light; hence, fabrication of complex graphene-based detectors is a challenging task. In this work, we utilize the ultrafast laser functionalization of single-layer CVD graphene for highly desirable maskless fabrication of micro- and nanoscale devices. We investigate the optoelectronic response of pristine and functionalized devices under femtosecond and continuous wave lasers irradiation. We demonstrate that the photocurrent generation in p–p+ junctions formed in single-layer graphene is related to the photothermoelectric effect. The photoresponsivity of our laser patterned single-layer graphene junctions is shown to be as high as 100 mA/W with noise equivalent power less than 6 kW/cm2. These results open a path to a low-cost maskless technology for fabrication of graphene-based optoelectronic devices with tunable properties for spectroscopy, signal processing, and other applications

    Comparative Study of Field-Effect Transistors Based on Graphene Oxide and CVD Graphene in Highly Sensitive NT-proBNP Aptasensors

    No full text
    Graphene-based materials are actively being investigated as sensing elements for the detection of different analytes. Both graphene grown by chemical vapor deposition (CVD) and graphene oxide (GO) produced by the modified Hummers’ method are actively used in the development of biosensors. The production costs of CVD graphene- and GO-based sensors are similar; however, the question remains regarding the most efficient graphene-based material for the construction of point-of-care diagnostic devices. To this end, in this work, we compare CVD graphene aptasensors with the aptasensors based on reduced GO (rGO) for their capabilities in the detection of NT-proBNP, which serves as the gold standard biomarker for heart failure. Both types of aptasensors were developed using commercial gold interdigitated electrodes (IDEs) with either CVD graphene or GO formed on top as a channel of liquid-gated field-effect transistor (FET), yielding GFET and rGO-FET sensors, respectively. The functional properties of the two types of aptasensors were compared. Both demonstrate good dynamic range from 10 fg/mL to 100 pg/mL. The limit of detection for NT-proBNP in artificial saliva was 100 fg/mL and 1 pg/mL for rGO-FET- and GFET-based aptasensors, respectively. While CVD GFET demonstrates less variations in parameters, higher sensitivity was demonstrated by the rGO-FET due to its higher roughness and larger bandgap. The demonstrated low cost and scalability of technology for both types of graphene-based aptasensors may be applicable for the development of different graphene-based biosensors for rapid, stable, on-site, and highly sensitive detection of diverse biochemical markers

    Humidity-enhanced sub-ppm sensitivity to ammonia of covalently functionalized single-wall carbon nanotube bundle layers

    No full text
    A low-cost method for carbon nanotubes (CNTs) network production from solutions on flexible polyethylene naphthalate substrates has been adopted to prepare high quality and well characterized SWCNT bundle layers to be used as the active layer in chemiresistor gas sensors. Two types of SWCNTs have been tested: pristine SWCNTs, deposited from a surfactant solution, and covalently functionalized SWCNTs, deposited from a dimethyl-acetamide solution. The humidity effects on the sensitivity of the SWCNTs network to NH 3 have been investigated. The results show that relative humidity favors the response to NH 3 , confirming recent theoretical predictions. The COOH-functionalized sample displays the largest response owing to both its hydrophilic nature, favoring the interaction with H 2 O molecules, and its largest surface area. Compared to data available in the literature, the present sensors display a remarkable sensitivity well below the ppm range, which makes them quite promising for environmental and medical applications, where NH 3 concentrations (mostly of the order of tens of ppb) have to be detected

    Spectral-Phase Interferometry Detection of Ochratoxin A via Aptamer-Functionalized Graphene Coated Glass

    No full text
    In this work, we report a novel method of label-free detection of small molecules based on direct observation of interferometric signal change in graphene-modified glasses. The interferometric sensor chips are fabricated via a conventional wet transfer method of CVD-grown graphene onto the glass coverslips, lowering the device cost and allowing for upscaling the sensor fabrication. For the first time, we report the use of graphene functionalized by the aptamer as the bioreceptor, in conjunction with Spectral-Phase Interferometry (SPI) for detection of ochratoxin A (OTA). In a direct assay with an OTA-specific aptamer, we demonstrated a quick and significant change of the optical signal in response to the maximum tolerable level of OTA concentration. The sensor regeneration is possible in urea solution. The developed platform enables a direct method of kinetic analysis of small molecules using a low-cost optical chip with a graphene-aptamer sensing layer

    Photothermoelectric response in asymmetric carbon nanotube devices exposed to sub-terahertz radiation

    No full text
    We report on the voltage response of carbon nanotube devices to sub-terahertz (THz) radiation. The devices contain carbon nanotubes (CNTs), which are over their length partially suspended and partially Van der Waals bonded to a SiO2 substrate, causing a difference in thermal contact. We observe a DC voltage upon exposure to 140?GHz radiation. Based on the observed gate voltage and power dependence, at different temperatures, we argue that the observed signal is both thermal and photovoltaic. The room temperature responsivity in the microwave to THz range exceeds that of CNT based devices reported before.QN/Quantum NanoscienceApplied Science

    Spectral-Phase Interferometry Detection of Ochratoxin A via Aptamer-Functionalized Graphene Coated Glass

    No full text
    In this work, we report a novel method of label-free detection of small molecules based on direct observation of interferometric signal change in graphene-modified glasses. The interferometric sensor chips are fabricated via a conventional wet transfer method of CVD-grown graphene onto the glass coverslips, lowering the device cost and allowing for upscaling the sensor fabrication. For the first time, we report the use of graphene functionalized by the aptamer as the bioreceptor, in conjunction with Spectral-Phase Interferometry (SPI) for detection of ochratoxin A (OTA). In a direct assay with an OTA-specific aptamer, we demonstrated a quick and significant change of the optical signal in response to the maximum tolerable level of OTA concentration. The sensor regeneration is possible in urea solution. The developed platform enables a direct method of kinetic analysis of small molecules using a low-cost optical chip with a graphene-aptamer sensing layer
    corecore