209 research outputs found

    Predicting the Focus of Cryogenicaly-Cooled Optical Systems

    Get PDF
    Results of an experimental study to ascertain how well the focal -plane location of cryogenically -cooled optical systems can be predicted are reported. These results indicate that if the required low- temperature thermal expansion and index -of- refraction data are available, the focal shift caused by cooling to cryogenic temperatures can be accurately predicted by simply computing the shift in the paraxial focus. In this study, the differences between the measured focal shifts and the computed shift in the paraxial focus were less than the diffraction -limited depth -of -focus tolerance. The results of this study also indicate that for off - the -shelf optical systems ray- tracing analysis may not adequately predict the absolute location of the focal plane. Thus, the following method of predicting the focal -plane location of a cryogenically- cooled optical system is suggested: first measure the focal -plane location with the optics at room temperature, and then add the computed paraxial focal shift to the measured location

    Use of CRISTA mesopause region temperatures for the intercalibration of gound-based instruments

    Get PDF
    Most available ground-based (GB) techniques for measuring temperatures in the upper mesosphere to lower thermosphere (or mesopause region) have systematic errors that are comparable to those of orbiting instruments. Determining these unknown biasses would normally require colocated observations that are only seldom feasible. Satellite measurements can be used as a ‘‘transfer standard’’ between GB observations that are not colocated. In this context, even with a reproducible or known bias in the satellite data, the comparison is still meaningful. Since Cryogenic Infrared Spectrometers and Telescopes for the Atmosphere (CRISTA) temperatures cover the mesopause region with very good accuracy (statistical errors do not exceed 1.5 K and systematic uncertainties range from about 3–7.5 K), they are quite suitable for this purpose. Because of the nearly constant precision over the height range of interest, also rotational temperatures of airglow emissions from different altitudes like the OH and O2 bands (or the OI 558 nm line) can be successfully compared with each other. In spite of the limited number of overpasses during the relatively short CRISTA missions, the feasibility of such an intercalibration is demonstrated for widely separated GB sites. Here, the results obtained for GB measurements at eight different sites, using CRISTA-1 and CRISTA-2 data, are presented. For OH temperatures, the standard deviation between the different instruments is only 5.4 K, confirming previous estimates.Fil: Scheer, Jurgen. Consejo Nacional de Investigaciónes Científicas y Técnicas. Oficina de Coordinación Administrativa Ciudad Universitaria. Instituto de Astronomía y Física del Espacio. - Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales. Instituto de Astronomía y Física del Espacio; ArgentinaFil: Reisin, Esteban Rodolfo. Consejo Nacional de Investigaciónes Científicas y Técnicas. Oficina de Coordinación Administrativa Ciudad Universitaria. Instituto de Astronomía y Física del Espacio. - Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales. Instituto de Astronomía y Física del Espacio; ArgentinaFil: Gusev, O. A.. University of Wuppertal; AlemaniaFil: French, W. J. R.. Australian Antarctic Division; AustraliaFil: Hernandez, G.. University of Washington; Estados UnidosFil: Huppi, R.. State University Of Utah; Estados UnidosFil: Ammosov, P.. Institute of Cosmophysical Research and Aeronomy; RusiaFil: Gavrilyeva, G. A.. Institute of Cosmophysical Research and Aeronomy; RusiaFil: Offermann, D.. University of Wuppertal; Alemani

    Developmental Changes and Injury Induced Disruption of the Radial Organization of the Cortex in the Immature Rat Brain Revealed by In Vivo Diffusion Tensor MRI

    Get PDF
    During brain development, morphological changes modify the cortex from its immature radial organization to its mature laminar appearance. Applying in vivo diffusion tensor imaging (DTI), the microstructural organization of the cortex in the immature rat was analyzed and correlated to neurohistopathology. Significant differences in apparent diffusion coefficient (ADC) and fractional anisotropy (FA) were detected between the external (I-III) and deep (IV-VI) cortical layers in postnatal day 3 (P3) and P6 pups. With cortical maturation, ADC was reduced in both cortical regions, whereas a decrease in FA was only seen in the deep layers. A distinct radial organization of the external cortical layers with the eigenvectors perpendicular to the pial surface was observed at both ages. Histology revealed maturational differences in the cortical architecture with increased neurodendritic density and reduction in the radial glia scaffolding. Early DTI after hypoxia-ischemia at P3 shows reduced ADC and FA in the ipsilateral cortex that persisted at P6. Cortical DTI eigenvector maps reveal microstructural disruption of the radial organization corresponding to regions of neuronal death, radial glial disruption, and astrocytosis. Thus, the combined use of in vivo DTI and histopathology can assist in delineating normal developmental changes and postinjury modifications in the immature rodent brai

    Geosynchronous Imaging Fourier Transform Spectrometer (GIFTS): Imaging and Tracking Capability

    Get PDF
    The geosynchronous-imaging Fourier transform spectrometer (GIFTS) engineering demonstration unit (EDU) is an imaging infrared spectrometer designed for atmospheric soundings. It measures the infrared spectrum in two spectral bands (14.6 to 8.8 microns, 6.0 to 4.4 microns) using two 128 128 detector arrays with a spectral resolution of 0.57/cm with a scan duration of approx. 11 seconds. From a geosynchronous orbit, the instrument will have the capability of taking successive measurements of such data to scan desired regions of the globe, from which atmospheric status, cloud parameters, wind field profiles, and other derived products can be retrieved. The GIFTS EDU provides a flexible and accurate testbed for the new challenges of the emerging hyperspectral era. The EDU ground-based measurement experiment, held in Logan, Utah during September 2006, demonstrated its extensive capabilities and potential for geosynchronous and other applications (e.g., Earth observing environmental measurements). This paper addresses the experiment objectives and overall performance of the sensor system with a focus on the GIFTS EDU imaging capability and proof of the GIFTS measurement concept

    GIFTS EDU Ground-based Measurement Experiment

    Get PDF
    Geosynchronous Imaging Fourier Transform Spectrometer (GIFTS) Engineering Demonstration Unit (EDU) is an imaging infrared spectrometer designed for atmospheric soundings. The EDU groundbased measurement experiment was held in Logan, Utah during September 2006 to demonstrate its extensive capabilities for geosynchronous and other applications

    Tractography of developing white matter of the internal capsule and corpus callosum in very preterm infants

    Get PDF
    To investigate in preterm infants associations between Diffusion Tensor Imaging (DTI) parameters of the posterior limb of the internal capsule (PLIC) and corpus callosum (CC) and age, white matter (WM) injury and clinical factors. In 84 preterm infants DTI was performed between 40-62 weeks postmenstrual age on 3 T MR. Fractional anisotropy (FA), apparent diffusion coefficient (ADC) values and fibre lengths through the PLIC and the genu and splenium were determined. WM injury was categorised as normal/mildly, moderately and severely abnormal. Associations between DTI parameters and age, WM injury and clinical factors were analysed. A positive association existed between FA and age at imaging for fibres through the PLIC (r = 0.48 p < 0.001) and splenium (r = 0.24 p < 0.01). A negative association existed between ADC and age at imaging for fibres through the PLIC (r = -0.65 p < 0.001), splenium (r = -0.35 p < 0.001) and genu (r = -0.53 p < 0.001). No association was found between DTI parameters and gestational age, degree of WM injury or categorical clinical factors. These results indicate that in our cohort of very preterm infants, at this young age, the development of the PLIC and CC is ongoing and independent of the degree of prematurity or WM injury.Neuro Imaging Researc

    Methodological consensus on clinical proton MRS of the brain: Review and recommendations

    Get PDF
    © 2019 International Society for Magnetic Resonance in Medicine Proton MRS (1H MRS) provides noninvasive, quantitative metabolite profiles of tissue and has been shown to aid the clinical management of several brain diseases. Although most modern clinical MR scanners support MRS capabilities, routine use is largely restricted to specialized centers with good access to MR research support. Widespread adoption has been slow for several reasons, and technical challenges toward obtaining reliable good-quality results have been identified as a contributing factor. Considerable progress has been made by the research community to address many of these challenges, and in this paper a consensus is presented on deficiencies in widely available MRS methodology and validated improvements that are currently in routine use at several clinical research institutions. In particular, the localization error for the PRESS localization sequence was found to be unacceptably high at 3 T, and use of the semi-adiabatic localization by adiabatic selective refocusing sequence is a recommended solution. Incorporation of simulated metabolite basis sets into analysis routines is recommended for reliably capturing the full spectral detail available from short TE acquisitions. In addition, the importance of achieving a highly homogenous static magnetic field (B0) in the acquisition region is emphasized, and the limitations of current methods and hardware are discussed. Most recommendations require only software improvements, greatly enhancing the capabilities of clinical MRS on existing hardware. Implementation of these recommendations should strengthen current clinical applications and advance progress toward developing and validating new MRS biomarkers for clinical use

    Poverty and Wellbeing Impacts of Microfinance : What Do We Know?

    Get PDF
    Over the last 35 years, microfinance has been generally regarded as an effective policy tool in the fight against poverty. Yet, the question of whether access to credit leads to poverty reduction and improved wellbeing remains open. To address this question, we conduct a systematic review of the quantitative literature of microfinance’s impacts in the developing world, and develop a theory of change that links inputs to impacts on several welfare outcomes. Overall, we find that the limited comparability of outcomes and the heterogeneity of microfinance-lending technologies, together with a considerable variation in socio-economic conditions and contexts in which impact studies have been conducted, render the interpretation and generalization of findings intricate. Our results indicate that, at best, microfinance induces short-term dynamism in the financial life of the poor; however, we do not find compelling evidence that this dynamism leads to increases in income, consumption, human capital and assets, and, ultimately, a reduction in poverty

    The Drosophila neural lineages: a model system to study brain development and circuitry

    Get PDF
    In Drosophila, neurons of the central nervous system are grouped into units called lineages. Each lineage contains cells derived from a single neuroblast. Due to its clonal nature, the Drosophila brain is a valuable model system to study neuron development and circuit formation. To better understand the mechanisms underlying brain development, genetic manipulation tools can be utilized within lineages to visualize, knock down, or over-express proteins. Here, we will introduce the formation and development of lineages, discuss how one can utilize this model system, offer a comprehensive list of known lineages and their respective markers, and then briefly review studies that have utilized Drosophila neural lineages with a look at how this model system can benefit future endeavors

    Geosynchronous Imaging Fourier Transform Spectrometer (GIFTS) Engineering Demonstation Unit (EDU) Overview and Performance Summary

    Get PDF
    The Geosynchronous Imaging Fourier Transform Spectrometer (GIFTS), developed for the NASA New Millennium Program (NMP) Earth Observing-3 (EO-3) mission, has recently completed a series of uplooking atmospheric measurements. The GIFTS development demonstrates a series of new sensor and data processing technologies that can significantly expand geostationary meteorological observational capability. The resulting increase in forecasting accuracy and atmospheric model development utilizing this hyperspectral data is demonstrated by the uplooking data. The GIFTS sensor is an imaging FTS with programmable spectral resolution and spatial scene selection, allowing spectral resolution and area coverage to be traded in near-real time. Due to funding limitations, the GIFTS sensor module was completed as an engineering demonstration unit that can be upgraded to flight quality. This paper reviews the GIFTS system design considerations and the technology utilized to enable a nearly two order performance increase over the existing GOES sounder and shows its capability. While not designed as an operational sensor, GIFTS EDU provides a flexible and accurate testbed for the new products the hyperspectral era will bring. Efforts to find funding to upgrade and demonstrate this amazing sensor in space are continuing
    • …
    corecore