161 research outputs found

    A COMPARISON OF BALANCE CONTROL BETWEEN JAVELIN THROWERS AND BASEBALL PITCHERS

    Get PDF
    This study evaluated the balance control in javelin throwers and baseball pitchers. Twenty-four athletes took part in the study and for each we measured their static and dynamic balance by Biodex Balance System, AMTl AccuSway force plate and Y balance test. The paired t-test was conducted to compare all the variables within subjects. The independent t-test was used to compare trail leg (TL) of baseball pitchers with propulsive leg (PL) of javelin throwers and stride leg (SL) of baseball pitchers with braking leg (BL) of javelin throwers. The results showed that there was no difference between the PL and BL in dynamic and static balance in javelin throwers. However, the dynamic balance in the TL was significantly better than the SL in baseball pitchers. The static balance in the PL in javelin throwers was also better than the TL in baseball pitchers. The research improves the understanding of balance control in elite athletes

    Measurements of normal inner ear on computed tomography in children with congenital sensorineural hearing loss

    Get PDF
    The objective of this study is to use standardized measurements of the inner ear to see whether there are subtle bony malformations in children with congenital sensorineural hearing loss (SNHL) whose temporal bone computed tomography (CT) are grossly normal. The study includes 45 ears with congenital SNHL and grossly normal temporal bone CT scans and 45 ears with normal inner ear structures and normal hearing. Standardized measurements of the inner ear structures were made on axial temporal bone CT scans. Student's t test was performed to compare the measurements of the two groups. There were significant differences in the measurements of the bony island width of the superior semicircular canal, bony island width of the lateral semicircular canal and maximal height of cochlea between two groups (P < 0.05). In conclusion, standardized measurements of bony labyrinth of inner ear on temporal bone CT can identify subtle abnormalities of inner ear in patients with congenital SNHL having grossly normal radiological images

    Antiflow of Nucleons at the Softest Point of the EoS

    Full text link
    We investigate flow in semi-peripheral nuclear collisions at AGS and SPS energies within macroscopic as well as microscopic transport models. The hot and dense zone assumes the shape of an ellipsoid which is tilted by an angle Theta with respect to the beam axis. If matter is close to the softest point of the equation of state, this ellipsoid expands predominantly orthogonal to the direction given by Theta. This antiflow component is responsible for the previously predicted reduction of the directed transverse momentum around the softest point of the equation of state.Comment: 13 pages LaTeX, 8 PS figures. Higher-quality PS versions of figures 3 and 4 available at http://www.th.physik.uni-frankfurt.de/~brachman/afl3f/afl3f.htm

    The combined role of MRI prostate and prostate health index in improving detection of significant prostate cancer in a screening population of Chinese men

    Get PDF
    Using prostate-specific antigen (PSA) for prostate cancer (PCa) screening led to overinvestigation and overdiagnosis of indolent PCa. We aimed to investigate the value of prostate health index (PHI) and magnetic resonance imaging (MRI) prostate in an Asian PCa screening program. Men aged 50-75 years were prospectively recruited from a community-based PSA screening program. Men with PSA 4.0-10.0 ng ml -1 had PHI result analyzed. MRI prostate was offered to men with PSA 4.0-50.0 ng ml -1. A systematic prostate biopsy was offered to men with PSA 4.0-9.9 ng ml -1 and PHI ≥35, or PSA 10.0-50.0 ng ml -1. Additional targeted prostate biopsy was offered if they had PI-RADS score ≥3. Clinically significant PCa (csPCa) was defined as the International Society of Urological Pathology (ISUP) grade group (GG) ≥2 or ISUP GG 1 with involvement of ≥30% of total systematic cores. In total, 12.8% (196/1536) men had PSA ≥4.0 ng ml -1. Among 194 men with PSA 4.0-50.0 ng ml -1, 187 (96.4%) received MRI prostate. Among them, 28.3% (53/187) had PI-RADS ≥3 lesions. Moreover, 7.0% (107/1536) men were indicated for biopsy and 94.4% (101/107) men received biopsy. Among the men received biopsy, PCa, ISUP GG ≥2 PCa, and csPCa was diagnosed in 42 (41.6%), 24 (23.8%), and 34 (33.7%) men, respectively. Compared with PSA/PHI pathway in men with PSA 4.0-50.0 ng ml -1, additional MRI increased diagnoses of PCa, ISUP GG ≥2 PCa, and csPCa by 21.2% (from 33 to 40), 22.2% (from 18 to 22), and 18.5% (from 27 to 32), respectively. The benefit of additional MRI was only observed in PSA 4.0-10.0 ng ml -1, and the number of MRI needed to diagnose one additional ISUP GG ≥2 PCa was 20 in PHI ≥35 and 94 in PHI &lt;35. Among them, 45.4% (89/196) men with PSA ≥4.0 ng ml -1 avoided unnecessary biopsy with the use of PHI and MRI. A screening algorithm with PSA, PHI, and MRI could effectively diagnose csPCa while reducing unnecessary biopsies. The benefit of MRI prostate was mainly observed in PSA 4.0-9.9 ng ml -1 and PHI ≥35 group. PHI was an important risk stratification step for PCa screening.</p

    Last Call for RHIC Predictions

    Get PDF
    This paper contains the individual contributions of all speakers of the session on 'Last Call for RHIC Predictions' at Quark Matter 99, and a summary by the convenor.Comment: 56 pages, psfig, epsf, epsfig, graphicx style files required, Proceedings of the XIV Int. Conf. on Nucleus-Nucleus Collisions, Quark Matter 99, Torino, Italy, May 10 - 15, 1999. Typographical mistakes corrected and figure numbers change

    Transient peristaltic transport of grains in a liquid

    Get PDF
    Pumping suspensions and pastes has always been a significant technological challenge in a number of industrial applications ranging from food processing to mining. Peristaltic pumps have become popular to pump and/or dose complex fluids, due to their robustness. During the transport of suspensions with peristaltic pumps, clogging issues may arise, particularly during transient operations. That is a matter of particular concern whenever the pumping device is used intermittently to generate flow only on demand. Further understanding of the transient dynamics of such systems and of the conditions that can lead to jamming would result in more robust peristaltic pump design. To achieve these goals, an experimental setup that simplifies the statorrotor assembly of a peristaltic hose pump was used. In this setup, a roller transfers momentum to a liquid suspension, upon application of a constant load. The evolution of the velocity of the roller was recorded for different concentrations of mono-dispersed spheres of different diameters. The flow is found not to be strongly dependent on the dispersed particle volume fraction, if the size of the suspended phase is comparable with the hose diameter. Conversely, the flow is strongly slowed down when their size is small and the particle concentration is increased. These findings could help improving the design of peristaltic pumps by a more appropriate sizing, given the diameter of the hose and that of the particles to be transported

    D* Production in Deep Inelastic Scattering at HERA

    Get PDF
    This paper presents measurements of D^{*\pm} production in deep inelastic scattering from collisions between 27.5 GeV positrons and 820 GeV protons. The data have been taken with the ZEUS detector at HERA. The decay channel D+(D0Kπ+)π+D^{*+}\to (D^0 \to K^- \pi^+) \pi^+ (+ c.c.) has been used in the study. The e+pe^+p cross section for inclusive D^{*\pm} production with 5<Q2<100GeV25<Q^2<100 GeV^2 and y<0.7y<0.7 is 5.3 \pms 1.0 \pms 0.8 nb in the kinematic region {1.3<pT(D±)<9.01.3<p_T(D^{*\pm})<9.0 GeV and η(D±)<1.5| \eta(D^{*\pm}) |<1.5}. Differential cross sections as functions of p_T(D^{*\pm}), η(D±),W\eta(D^{*\pm}), W and Q2Q^2 are compared with next-to-leading order QCD calculations based on the photon-gluon fusion production mechanism. After an extrapolation of the cross section to the full kinematic region in p_T(D^{*\pm}) and η\eta(D^{*\pm}), the charm contribution F2ccˉ(x,Q2)F_2^{c\bar{c}}(x,Q^2) to the proton structure function is determined for Bjorken xx between 2 \cdot 104^{-4} and 5 \cdot 103^{-3}.Comment: 17 pages including 4 figure

    Observation of Scaling Violations in Scaled Momentum Distributions at HERA

    Get PDF
    Charged particle production has been measured in deep inelastic scattering (DIS) events over a large range of xx and Q2Q^2 using the ZEUS detector. The evolution of the scaled momentum, xpx_p, with Q2,Q^2, in the range 10 to 1280 GeV2GeV^2, has been investigated in the current fragmentation region of the Breit frame. The results show clear evidence, in a single experiment, for scaling violations in scaled momenta as a function of Q2Q^2.Comment: 21 pages including 4 figures, to be published in Physics Letters B. Two references adde
    corecore