979 research outputs found
Pulse shape discrimination performance of Inverted Coaxial Ge detectors
We report on the characterization of two inverted coaxial Ge detectors in the
context of being employed in future Ge neutrinoless double beta
() decay experiments. It is an advantage that such detectors
can be produced with bigger Ge mass as compared to the planar Broad Energy Ge
detectors (BEGe) that are currently used in the GERDA decay
experiment. This will result in lower background for the search of
decay due to a reduction of cables, electronics and holders.
The measured resolution near the Ge Q-value at 2039 keV is 2.5 keV and
their pulse-shape characteristics are similar to BEGe-detectors. It is
concluded that this type of Ge-detector is suitable for usage in Ge
decay experiments
A and B antigen levels acquired by group O donor-derived erythrocytes following ABO-non-identical transfusion or minor ABO-incompatible haematopoietic stem cell transplantation
BACKGROUND AND OBJECTIVES: ABO-incompatible haematopoietic stem cell transplantation (HSCT) presents a challenge to blood component transfusion. The aim of this study was to investigate the weak blood group A or B antigen expression by donor-derived group O red blood cells (RBC) observed following transfusion or minor ABO-incompatible HSCT. In addition, in vitro experiments were performed to elucidate possible mechanisms underlying this phenomenon.MATERIALS AND METHODS: A sensitive flow cytometry assay for the semi-quantification of RBC A/B antigen levels was used to assess patient samples and evaluate in vitro experiments.RESULTS: Analysis of blood samples from patients, originally typed as A, B and AB but recently transplanted or transfused with cells from group O donors, revealed the A antigen expression on donor-derived RBC, ranging from very low levels in non-secretor individuals to almost subgroup Ax -like profiles in group A secretors. The B antigen expression was less readily detectable. In vitro experiments, in which group O donor RBC were incubated with (i) group A/B secretor/non-secretor donor plasma or (ii) group A/B donor RBC in the absence of plasma, supported the proposed adsorption of A/B antigen-bearing glycolipids from secretor plasma but also indicated a secretor-independent mechanism for A/B antigen acquisition as well as direct cell-to-cell transfer of ABO antigens.CONCLUSION: The in vivo conversion of donor-derived blood group O RBC to ABO subgroup-like RBC after transfusion or minor ABO-incompatible HSCT raises the question of appropriate component selection. Based on these data, AB plasma should be transfused following ABO-incompatible HSCT
A calibration method for broad-bandwidth cavity enhanced absorption spectroscopy performed with supercontinuum radiation
An efficient calibration method has been developed for broad-bandwidth cavity enhanced absorption spectroscopy. The calibration is performed using phase shift cavity ring-down spectroscopy, which is conveniently implemented through use of an acousto-optic tunable filter (AOTF). The AOTF permits a narrowband portion of the SC spectrum to be scanned over the full high-reflectivity bandwidth of the cavity mirrors. After calibration the AOTF is switched off and broad-bandwidth CEAS can be performed with the same light source without any loss of alignment to the set-up. We demonstrate the merits of the method by probing transitions of oxygen molecules O-2 and collisional pairs of oxygen molecules (O-2)(2) in the visible spectral range
Unified Treatment of Asymptotic van der Waals Forces
In a framework for long-range density-functional theory we present a unified
full-field treatment of the asymptotic van der Waals interaction for atoms,
molecules, surfaces, and other objects. The only input needed consists of the
electron densities of the interacting fragments and the static polarizability
or the static image plane, which can be easily evaluated in a ground-state
density-functional calculation for each fragment. Results for separated atoms,
molecules, and for atoms/molecules outside surfaces are in agreement with those
of other, more elaborate, calculations.Comment: 6 pages, 5 figure
Factor copula models for item response data
Factor or conditional independence models based on copulas are proposed for multivariate discrete data such as item responses. The factor copula models have interpretations of latent maxima/minima (in comparison with latent means) and can lead to more probability in the joint upper or lower tail compared with factor models based on the discretized multivariate normal distribution (or multidimensional normal ogive model). Details on maximum likelihood estimation of parameters for the factor copula model are given, as well as analysis of the behavior of the log-likelihood. Our general methodology is illustrated with several item response data sets, and it is shown that there is a substantial improvement on existing models both conceptually and in fit to data
Mode-hop-free tuning over 135 GHz of external cavity diode lasers without anti-reflection coating
We report an external cavity diode laser (ECDL), using a diode whose front
facet is not antireflection (AR) coated, that has a mode-hop-free (MHF) tuning
range greater than 135 GHz. We achieved this using a short external cavity and
by simultaneously tuning the internal and external modes of the laser. We find
that the precise location of the pivot point of the grating in our laser is
less critical than commonly believed. The general applicability of the method,
combined with the compact portable mechanical and electronic design, makes it
well suited for both research and industrial applications.Comment: 5 pages, 5 figure
Characterization of 30 Ge enriched Broad Energy Ge detectors for GERDA Phase II
The GERmanium Detector Array (GERDA) is a low background experiment located
at the Laboratori Nazionali del Gran Sasso in Italy, which searches for
neutrinoless double beta decay of Ge into Se+2e. GERDA has
been conceived in two phases. Phase II, which started in December 2015,
features several novelties including 30 new Ge detectors. These were
manufactured according to the Broad Energy Germanium (BEGe) detector design
that has a better background discrimination capability and energy resolution
compared to formerly widely-used types. Prior to their installation, the new
BEGe detectors were mounted in vacuum cryostats and characterized in detail in
the HADES underground laboratory in Belgium. This paper describes the
properties and the overall performance of these detectors during operation in
vacuum. The characterization campaign provided not only direct input for GERDA
Phase II data collection and analyses, but also allowed to study detector
phenomena, detector correlations as well as to test the strength of pulse shape
simulation codes.Comment: 29 pages, 18 figure
Background free search for neutrinoless double beta decay with GERDA Phase II
The Standard Model of particle physics cannot explain the dominance of matter
over anti-matter in our Universe. In many model extensions this is a very
natural consequence of neutrinos being their own anti-particles (Majorana
particles) which implies that a lepton number violating radioactive decay named
neutrinoless double beta () decay should exist. The detection
of this extremely rare hypothetical process requires utmost suppression of any
kind of backgrounds.
The GERDA collaboration searches for decay of Ge
(^{76}\rm{Ge} \rightarrow\,^{76}\rm{Se} + 2e^-) by operating bare detectors
made from germanium with enriched Ge fraction in liquid argon. Here, we
report on first data of GERDA Phase II. A background level of
cts/(keVkgyr) has been achieved which is the world-best if
weighted by the narrow energy-signal region of germanium detectors. Combining
Phase I and II data we find no signal and deduce a new lower limit for the
half-life of yr at 90 % C.L. Our sensitivity of
yr is competitive with the one of experiments with
significantly larger isotope mass.
GERDA is the first experiment that will be background-free
up to its design exposure. This progress relies on a novel active veto system,
the superior germanium detector energy resolution and the improved background
recognition of our new detectors. The unique discovery potential of an
essentially background-free search for decay motivates a
larger germanium experiment with higher sensitivity.Comment: 14 pages, 9 figures, 1 table; ; data, figures and images available at
http://www.mpi-hd.mpg/gerda/publi
Flux Modulations seen by the Muon Veto of the GERDA Experiment
The GERDA experiment at LNGS of INFN is equipped with an active muon veto.
The main part of the system is a water Cherenkov veto with 66~PMTs in the water
tank surrounding the GERDA cryostat. The muon flux recorded by this veto shows
a seasonal modulation. Two effects have been identified which are caused by
secondary muons from the CNGS neutrino beam (2.2 %) and a temperature
modulation of the atmosphere (1.4 %). A mean cosmic muon rate of /(sm) was found in good agreement with other experiments at