199 research outputs found

    Field dependence of electronic recoil signals in a dual-phase liquid xenon time projection chamber

    Get PDF
    We present measurements of light and charge signals in a dual-phase time projection chamber at electric fields varying from 10 V/cm up to 500 V/cm and at zero field using 511 keV gamma rays from a 22^{22}Na source. We determine the drift velocity, electron lifetime, diffusion constant, and light and charge yields at 511 keV as a function of the electric field. In addition, we fit the scintillation pulse shape to an effective exponential model, showing a decay time of 43.5 ns at low field that decreases to 25 ns at high fields.Comment: 14 pages, 8 figure

    Precision measurements of the scintillation pulse shape for low-energy recoils in liquid xenon

    Get PDF
    We present measurements of the scintillation pulse shape in liquid xenon for nuclear recoils (NR) and electronic recoils (ER) at electric fields of 0 to 0.5 kV/cm for energies << 15 keV and << 70 keV electron-equivalent, respectively. The average pulse shapes are well-described by an effective model with two exponential decay components, where both decay times are fit parameters. We find significant broadening of the pulse for ER due to delayed luminescence from the recombination process. In addition to the effective model, we fit a model describing the recombination luminescence for ER at zero field and obtain good agreement. We estimate the best performance of a combined S2/S1 and pulse shape ER/NR discrimination and show that even with 2 ns time resolution, the improvement over S2/S1 discrimination alone is marginal, so that pulse shape discrimination will likely not be useful for future dual-phase liquid xenon experiments looking for elastic dark matter recoil interactions

    Prediction of sustained remission after tyrosine kinase inhibitor discontinuation with BCR::ABL1 digital PCR in chronic myeloid leukemia patients

    Get PDF
    Precise and reliable predictive parameters to accurately identify chronic myeloid leukemia (CML) patients who can successfully discontinue their tyrosine kinase inhibitor (TKI) treatment are lacking. One promising parameter is depth of molecular response measured by BCR::ABL1 digital PCR (dPCR). The aim of this study was to validate a previously described prediction cutoff of 0.0023%IS and to assess the value of dPCR for treatment-free remission (TFR) prediction in relation to other clinical parameters. A droplet-based dPCR assay assessed BCR::ABL1 %IS prior to TKI discontinuation. The primary endpoint was molecular recurrence (MolR) by 36 months. A total of 186 patients from Canada, Germany, and the Netherlands were included. In patients with a first TKI discontinuation attempt (n = 163), a BCR::ABL1 dPCR &lt; and ≥0.0023%IS had a MolR probability of 33% and 70%, respectively. Patients treated less than 6 years with a BCR::ABL1 dPCR &lt;0.0023%IS had a MolR probability of 31%. After correction for treatment duration, both high dPCR value and the use of imatinib (vs. second-generation TKI) were significantly associated with a higher risk of MolR (HR of 3.66, 95%CI 2.06–6.51, p &lt;.001; and 2.85, 95%CI 1.25–6.46, p =.013, respectively). BCR::ABL1 dPCR was not associated with TFR outcome after second TKI discontinuation, however, with the limitation of a small number of patients analyzed (n = 23). In conclusion, BCR::ABL1 digital PCR based on the cutoff of 0.0023%IS is a valuable predictive tool to identify CML patients with a high probability of TFR success after first TKI discontinuation, including patients treated for less than 6 years.</p

    Actual postoperative protein and calorie intake in patients undergoing major open abdominal cancer surgery:A prospective, observational cohort study

    Get PDF
    Background Adequate nutritional protein and energy intake are required for optimal postoperative recovery. There are limited studies reporting the actual postoperative protein and energy intake within the first week after major abdominal cancer surgery. The main objective of this study was to quantify the protein and energy intake after major abdominal cancer surgery. Methods We conducted a prospective cohort study. Nutrition intake was assessed with a nutrition diary. The amount of protein and energy consumed through oral, enteral, and parenteral nutrition was recorded and calculated separately. Based on the recommendations of the European Society for Clinical Nutrition and Metabolism (ESPEN), protein and energy intake were considered insufficient when patients received Fifty patients were enrolled in this study. Mean daily protein and energy intake was 0.61 +/- 0.44 g/kg/day and 9.58 +/- 3.33 kcal/kg/day within the first postoperative week, respectively. Protein and energy intake were insufficient in 45 [90%] and 41 [82%] of the 50 patients, respectively. Patients with Clavien-Dindo grade >= III complications consumed less daily protein compared with the group of patients without complications and patients with grade I or II complications. Conclusion During the first week after major abdominal cancer surgery, the majority of patients do not consume an adequate amount of protein and energy. Incorporating a registered dietitian into postoperative care and adequate nutrition support after major abdominal cancer surgery should be a standard therapeutic goal to improve nutrition intake

    New polymorphic DNA marker close to the fragile site FRAXA

    Get PDF
    Abstract DNA from a human-hamster hybrid cell line, 908-K1B17, containing a small terminal portion of the long arm of the human X chromosome as well as the pericentric region of 19q was used as starting material for the isolation of an X-chromosome-specific DNA segment, RN1 (DXS369), which identifies a XmnI RFLP. Linkage analysis in fragile X families resulted in a maximum lod score of 15.3 at a recombination fraction of 0.05 between RN1 and fra(X). Analysis of recombinations around the fra(X) locus assigned RN1 proximal to fra(X) and distal to DXS105. Analysis of the marker content of hybrid cell line 908K1B17 suggests the localization of RN1 between DXS98 and fra(X). Heterozygosity of DXS369 is approximately 50%, which extends the diagnostic potential of RFLP analysis in fragile X families significantly

    Automatic quantification of lymphocyte vacuolization in peripheral blood smears of patients with Batten's disease (CLN3 disease)

    Get PDF
    Quantifying lymphocyte vacuolization in peripheral blood smears (PBSs) serves as a measure for disease severity in CLN3 disease—a lysosomal storage disorder of childhood-onset. However, thus far quantification methods are based on labor-intensive manual assessment of PBSs. As machine learning techniques like convolutional neural networks (CNNs) have been deployed quite successfully in detecting pathological features in PBSs, we explored whether these techniques could be utilized to automate quantification of lymphocyte vacuolization. Here, we present and validate a deep learning pipeline that automates quantification of lymphocyte vacuolization. By using two CNNs in succession, trained for cytoplasm-segmentation and vacuolization-detection, respectively, we obtained an excellent correlation with manual quantification of lymphocyte vacuolization (r = 0.98, n = 40). These results show that CNNs can be utilized to automate the otherwise cumbersome task of manually quantifying lymphocyte vacuolization, thereby aiding prompt clinical decisions in relation to CLN3 disease, and potentially beyond

    Removing krypton from xenon by cryogenic distillation to the ppq level

    Get PDF
    The XENON1T experiment aims for the direct detection of dark matter in a cryostat filled with 3.3 tons of liquid xenon. In order to achieve the desired sensitivity, the background induced by radioactive decays inside the detector has to be sufficiently low. One major contributor is the β\beta-emitter 85^{85}Kr which is an intrinsic contamination of the xenon. For the XENON1T experiment a concentration of natural krypton in xenon nat\rm{^{nat}}Kr/Xe < 200 ppq (parts per quadrillion, 1 ppq = 1015^{-15} mol/mol) is required. In this work, the design of a novel cryogenic distillation column using the common McCabe-Thiele approach is described. The system demonstrated a krypton reduction factor of 6.4\cdot105^5 with thermodynamic stability at process speeds above 3 kg/h. The resulting concentration of nat\rm{^{nat}}Kr/Xe < 26 ppq is the lowest ever achieved, almost one order of magnitude below the requirements for XENON1T and even sufficient for future dark matter experiments using liquid xenon, such as XENONnT and DARWIN

    Search for Two-Neutrino Double Electron Capture of 124^{124}Xe with XENON100

    Get PDF
    Two-neutrino double electron capture is a rare nuclear decay where two electrons are simultaneously captured from the atomic shell. For 124^{124}Xe this process has not yet been observed and its detection would provide a new reference for nuclear matrix element calculations. We have conducted a search for two-neutrino double electron capture from the K-shell of 124^{124}Xe using 7636 kg\cdotd of data from the XENON100 dark matter detector. Using a Bayesian analysis we observed no significant excess above background, leading to a lower 90 % credibility limit on the half-life T1/2>6.5×1020T_{1/2}>6.5\times10^{20} yr. We also evaluated the sensitivity of the XENON1T experiment, which is currently being commissioned, and find a sensitivity of T1/2>6.1×1022T_{1/2}>6.1\times10^{22} yr after an exposure of 2 t\cdotyr.Comment: 6 pages, 4 figure
    corecore