70 research outputs found

    Construction of the Soudan 2 detector

    Get PDF
    Progress in the construction of the Soudan 2 nucleon decay detector which is being built at the Soudan iron mine in Minnesota is discussed. The expected event rate and characteristics of low energy neutrino events, muon events, multiple muon events, and other cosmic ray phenomena are discussed

    Spatial Resolution Attainable with Cathode Strip Chambers at the Trigger Level

    Get PDF
    A simple network of comparators applied to the strip signals of a cathode strip chamber allows quick hit localization to within a halfstrip width, or +/- a quarter-strip. A six-plane chamber with 6.4 mm wide strips was tested in a high-energy muon beam. The chamber was placed behind a 30 cm thick iron block. We show that patterns of hits localized to within a halfstrip allowed us to identify 300 GeV/c muon tracks with 99% probability and 0.7 mm spatial resolution in the presence of muon bremsstrahlung radiation. This technique of finding muon tracks will be used in the cathode strip chambers of the CMS Endcap Muon System

    Risk of upper gastrointestinal bleeding and perforation associated with low-dose aspirin as plain and enteric-coated formulations

    Get PDF
    BACKGROUND: The use of low-dose aspirin has been reported to be associated with an increased risk of upper gastrointestinal complications (UGIC). The coating of aspirin has been proposed as an approach to reduce such a risk. To test this hypothesis, we carried out a population based case-control study. METHODS: We identified incident cases of UGIC (bleeding or perforation) aged 40 to 79 years between April 1993 to October 1998 registered in the General Practice Research Database. Controls were selected randomly from the source population. Adjusted estimates of relative risk (RR) associated with current use of aspirin as compared to non use were computed using unconditional logistic regression. RESULTS: We identified 2,105 cases of UGIC and selected 11,500 controls. Among them, 287 (13.6%) cases and 837 (7.3%) controls were exposed to aspirin, resulting in an adjusted RR of 2.0 (1.7-2.3). No clear dose-effect was found within the range of 75-300 mg. The RR associated with enteric-coated formulations (2.3, 1.6-3.2) was similar to the one of plain aspirin (1.9, 1.6-2.3), and no difference was observed depending on the site. The first two months of treatment was the period of greater risk (RR= 4.5, 2.9-7.1). The concomitant use of aspirin with high-dose NSAIDs greatly increased the risk of UGIC (13.3, 8.5-20.9) while no interaction was apparent with low-medium doses (2.2, 1.0-4.6). CONCLUSIONS: Low-dose aspirin increases by twofold the risk of UGIC in the general population and its coating does not modify the effect. Concomitant use of low-dose aspirin and NSAIDs at high doses put patients at a specially high risk of UGIC

    Spontaneous twin anemia polycythemia sequence: diagnosis, management, and outcome in an international cohort of 249 cases.

    Get PDF
    BACKGROUND: Twin anemia polycythemia sequence is a chronic form of unbalanced fetofetal transfusion through minuscule placental anastomoses in monochorionic twins, leading to anemia in the donor and polycythemia in the recipient. Owing to the low incidence of twin anemia polycythemia sequence, data on diagnosis, management, and outcome are limited. OBJECTIVE: This study aimed to investigate the diagnosis, management, and outcome in a large international cohort of spontaneous twin anemia polycythemia sequence. STUDY DESIGN: Data from the international twin anemia polycythemia sequence registry, retrospectively collected between 2014 and 2019, were used for this study. A total of 17 fetal therapy centers contributed to the data collection. The primary outcomes were perinatal mortality and severe neonatal morbidity. Secondary outcomes included a risk factor analysis for perinatal mortality and severe neonatal morbidity. RESULTS: A total of 249 cases of spontaneous twin anemia polycythemia sequence were included in this study, 219 (88%) of which were diagnosed antenatally and 30 (12%) postnatally. Twin anemia polycythemia sequence was diagnosed antenatally at a median gestational age of 23.7 weeks (interquartile range, 9.7-28.8; range, 15.1-35.3). Antenatal management included laser surgery in 39% (86 of 219), expectant management in 23% (51 of 219), delivery in 16% (34 of 219), intrauterine transfusion (with partial exchange transfusion) in 12% (26 of 219), selective feticide in 8% (18 of 219), and termination of pregnancy in 1% (3 of 219) of cases. Perinatal mortality rate was 15% (72 of 493) for the total group, 22% (54 of 243) for donors, and 7% (18 of 242) for recipients (P<.001). Severe neonatal morbidity occurred in 33% (141 of 432) of twins with twin anemia polycythemia sequence and was similar for donors (32%; 63 of 196) and recipients (33%; 75 of 228) (P=.628). Independent risk factors for spontaneous perinatal mortality were donor status (odds ratio, 3.8; 95% confidence interval, 1.9-7.5; P<.001), antenatal twin anemia polycythemia sequence stage (odds ratio, 6.3; 95% confidence interval, 1.4-27.8; P=.016 [stage 2]; odds ratio, 9.6; 95% confidence interval, 2.1-45.5; P=.005 [stage 3]; odds ratio, 20.9; 95% confidence interval, 3.0-146.4; P=.002 [stage 4]), and gestational age at birth (odds ratio, 0.8; 95% confidence interval, 0.7-0.9; P=.001). Independent risk factors for severe neonatal morbidity were antenatal twin anemia polycythemia sequence stage 4 (odds ratio, 7.9; 95% confidence interval, 1.4-43.3; P=.018) and gestational age at birth (odds ratio, 1.7; 95% confidence interval, 1.5-2.1, P<.001). CONCLUSION: Spontaneous twin anemia polycythemia sequence can develop at any time in pregnancy from the beginning of the second trimester to the end of the third trimester. Management for twin anemia polycythemia sequence varies considerably, with laser surgery being the most frequent intervention. Perinatal mortality and severe neonatal morbidity were high, the former especially so in the donor twins

    Measurement of the mass difference m(D-s(+))-m(D+) at CDF II

    Get PDF
    We present a measurement of the mass difference m(D-s(+))-m(D+), where both the D-s(+) and D+ are reconstructed in the phipi(+) decay channel. This measurement uses 11.6 pb(-1) of data collected by CDF II using the new displaced-track trigger. The mass difference is found to be m(D-s(+))-m(D+)=99.41+/-0.38(stat)+/-0.21(syst) MeV/c(2)

    Neonatal hypoglycaemia and body proportionality in small for gestational age newborns: a retrospective cohort study

    No full text
    Small for gestational age (SGA) newborns are at risk of developing neonatal hypoglycaemia. SGA newborns comprise a heterogeneous group including both constitutionally small and pathologically growth restricted newborns. The process of fetal growth restriction may result in brain sparing at the expense of the rest of the body, resulting in disproportionally small newborns. The aim of this study was to discover whether body proportionality influences the risk of developing neonatal hypoglycaemia in SGA newborns. A retrospective cohort study was performed in 402 newborns who were SGA without additional risk factors for hypoglycaemia. Body proportionality was classified in two ways: (1) using symmetric (sSGA) or asymmetric (aSGA), defined as head circumference (HC) below or above the 10th percentile, respectively; (2) using cephalization index (HC/birth weight), standardized for gestational age. Hypoglycaemia was observed in 50% of aSGA and 40.9% of sSGA newborns (P-value 0.12). Standardized CI in newborns with hypoglycaemia was higher compared to newborns without hypoglycaemia (median 1.27 (1.21-1.35) versus 1.24 (1.20-1.29); (P 0.002)). Multivariate logistic regression analyses showed both CI and standardized CI to be associated with the occurrence of hypoglycaemia (OR 1.48 (1.24-1.77) and OR 1.44 (1.13-1.83), respectively). The majority of hypoglycaemic events (96.1%) occurred in the first 6 h after birth.   Conclusion: Body proportionality might be of influence, depending on the classification used. Larger prospective studies with a clear consensus definition of body proportionality are needed. What is Known: ‱ Neonatal hypoglycaemia is an important complication in newborns. ‱ Small for gestational age (SGA) newborns are more vulnerable to hypoglycaemia. What is New: ‱ Higher incidence of hypoglycaemia was not observed in asymmetric SGA compared to symmetric SGA, but standardized cephalization index was associated with increased likelihood of hypoglycaemia. ‱ Consensus-based definitions of body proportionality in newborns are needed

    Long-term patient-reported outcome measures following limb salvage with complex reconstruction or amputation in the treatment of upper extremity sarcoma

    No full text
    BACKGROUND AND OBJECTIVES: This study compares long-term patient-reported outcomes between patients that underwent limb-salvage surgery with complex reconstruction by free or pedicled flap (LS) or amputation. Additionally, the need for revision surgery is compared. METHODS: A total of 43 patients were studied at a median follow-up of 9.54 years. Sixteen patients completed questionnaires regarding functional outcome and mental wellbeing. Functional outcomes were measured by using the Toronto Extremity Salvage Score (TESS), QuickDASH, and PROMIS Upper Extremity instruments. Mental wellbeing was assessed using the PROMIS Anxiety and Depression instruments. Revision surgery was assessed for the entire follow-up. RESULTS: The median TESS scores were 96.0 versus 71.7 (pn=n0.034) and the PROMIS Upper Extremity scores were 50.1 versus 40.3 (pn=n0.039) for the LS and amputation cohorts, respectively. No significant difference was found regarding symptoms of anxiety (52.7 vs. 53.8; pn=n0.587) or depression (52.0 vs. 50.5; pn=n0.745). Of the patients in the LS cohort 51.6% required at least one reoperation compared to 8.33% in the amputation cohort. CONCLUSIONS: LS surgery maintains functional benefits over amputation after almost a decade of follow-up. Still, mental wellbeing seems to be comparable between these patients, whereas LS procedures are associated with a sixfold increased need for reoperations

    Online Track Processor for the CDF Upgrade

    Get PDF
    A trigger track processor is being designed for the CDF upgrade. This processor identifies high momentum (PT \u3e 1.5 GeV/c) charged tracks in the new central outer tracking chamber for CDF 11. The track processor is called the extremely Fast Tracker (XFT). The XFT design is highly parallel to handle the input rate of 183 Gbits/sec and output rate of 44 Gbitslsec. The processor is pipelined and reports the results for a new event every 132 ns. The processor uses three stages, hit classification, segment finding, and segment linking. The pattern recognition algorithms for the three stages are implemented in programmable logic devices (PLDs) which allow for in-situ modification of the algorithm at any time. The PLDs reside on three different types of modules. Prototypes of each of these modules have been designed and built, and are presently undergoing testing. An overview of the track processor and results of testing are presented
    • 

    corecore