194 research outputs found

    Changes of intracellular sodium and potassium ion concentrations in frog spinal motoneurons induced by repetitive synaptic stimulation

    Get PDF
    A post-tetanic membrane hyperpolarization following repetitive neuronal activity is a commonly observed phenomenon in the isolated frog spinal cord as well as in neurons of other nervous tissues. We have now used double-barrelled Na+- and K+-ion-sensitive microelectrodes to measure the intracellular Na+- and K+-concentrations and also the extracellular K+-concentration of lumbar spinal motoneurons during and after repetitive stimulation of a dorsal root. The results show that the posttetanic membrane hyperpolarization occurred at a time when the intracellular [Na+] reached its maximal value, intracellular [K+] had its lowest level and extracellular [K+] was still elevated. The hyperpolarization was blocked by ouabain and reduced by Li+. These data support the previous suggestion that an electrogenic Na+/K+ pump mode may be the mechanism underlying the post-tetanic membrane hyperpolarization

    CBT4BN: A Randomized Controlled Trial of Online Chat and Face-to-Face Group Therapy for Bulimia Nervosa

    Get PDF
    Although cognitive-behavioral therapy (CBT) represents the first-line evidence-based psychotherapy for bulimia nervosa (BN), most individuals seeking treatment do not have access to this specialized intervention. We compared an Internet-based manualized version of CBT group therapy for BN conducted via a therapeutic chat group (CBT4BN) to the same treatment conducted via a traditional face-to-face group therapy (CBTF2F)

    Novel methodology for predicting the critical salt concentration of bubble coalescence inhibition

    Get PDF
    Bubble coalescence in some salt solutions can be inhibited if the salt concentration reaches a critical concentration Ccr. There are three models available for Ccr in the literature, but they fail to predict Ccr correctly. The first two models employ the van der Waals attraction power laws to establish Ccr from the discriminant of quadratic or cubic polynomials. To improve the two models, the third model uses the same momentum balance equation of the previous models but different intermolecular force generated by water hydration with exponential decaying. The third prediction for Ccr requires the experimental input for film rupture thickness and is incomplete. We show further in this paper that the third model is incorrect. We propose a novel methodology for determining C cr which resolves the mathematical uncertainties in modeling C cr and can explicitly predict it from any relevant intermolecular forces. The methodology is based on the discovery that Ccr occurs at the local maximum of the balance equation for the capillary pressure, disjoining pressure, and pressure of the Gibbs-Marangoni stress. The novel generic approach is successfully validated using nonlinear equations for complicated disjoining pressure

    European Surveillance System on Contact Allergies (ESSCA): Characteristics of patients patch tested and diagnosed with irritant contact dermatitis

    Get PDF
    Background Irritant contact dermatitis (ICD) is caused by the acute locally toxic effect of a strong irritant, or the cumulative exposure to various weaker physical and/or chemical irritants. Objectives To describe the characteristics of patients with ICD in the population patch tested in the European Surveillance System on Contact Allergies (ESSCA; ) database. Methods Data collected by the ESSCA in consecutively patch-tested patients from January 2009 to December 2018 were analyzed. Results Of the 68 072 patients, 8702 were diagnosed with ICD (without concomitant allergic contact dermatitis [ACD]). Hand and face were the most reported anatomical sites, and 45.7% of the ICD was occupational ICD (OICD). The highest proportions of OICD were found in metal turners, bakers, pastry cooks, and confectionery makers. Among patients diagnosed with ICD, 45% were found sensitized with no relevance for the current disease. Conclusions The hands were mainly involved in OICD also in the subgroup of patients with contact dermatitis, in whom relevant contact sensitization had been ruled out, emphasizing the need for limiting irritant exposures. However, in difficult-to-treat contact dermatitis, unrecognized contact allergy, or unrecognized clinical relevance of identified allergies owing to incomplete or wrong product ingredient information must always be considered

    7th Drug hypersensitivity meeting: part two

    Get PDF
    No abstract availabl

    Untersuchungen zur Radiooekologie des Tritiums in Marburg und Umgebung 1981: Strahlenbelastung der Population durch Inkorporation von Tritium

    No full text
    SIGLECopy held by FIZ Karlsruhe; available from UB/TIB Hannover / FIZ - Fachinformationszzentrum Karlsruhe / TIB - Technische InformationsbibliothekDEGerman

    Combined biotin-terpyridine systems : a new versatile bridge between biology, polymer science and metallo-supramolecular chemistry

    No full text
    Biotin, a well-known binding unit for the proteins avidin and streptavidin, was combined with the chelating ligand terpyridine via polymeric and nonpolymeric spacers. An Âż-amino-functionalized terpyridyl-poly(ethylene glycol) was prepared and utilized for complex formation with iron(II), nickel(II), and ruthenium(II) ions. The biocompatibility of the complex formation was investigated in aqueous media. Moreover, biotin was functionalized with a methoxy-poly(ethylene glycol) as a model system. The compounds were characterized by UV/vis and NMR spectroscopy as well as MALDI-TOF mass spectrometry. The systems represent a new combination of strong noncovalent binding units from both biology and synthetic supramolecular chemistry

    Metal hypersensitivity in patients with orthopaedic implant complications-A retrospective clinical study

    No full text
    Hypersensitivity to metals as a cause of implant-related complications has been a subject of controversy. Projections indicate an increase in the frequency of joint replacements of between 300% and 600% by the year 2030; therefore, this issue is of considerable interest.; To evaluate sensitization to implant materials in patients with implant-related complications, to identify allergens, and to clarify whether hypersensitivity is a relevant cause.; Patients with implant-related complications or a positive history of contact allergy and planned total joint replacements referred for allergological investigation between 2004 and 2017 were retrospectively analysed.; In total, 311 patients were included. A positive patch test reaction to a metal was seen in 64.4% of preoperative patients and in 54.6% of patients with implant-related complications. Common alloy metals such as cobalt, chromium and titanium gave positive reactions in up to 2.9% of patients with implant-related complications. None of the patients with skin changes had a positive patch test reaction to an implant metal.; Other factors, such as the type of replaced joint and mechanical stress, seem to be more relevant for implant-related complications. Sensitization to metals or other materials seems to rarely play a role, and is overestimated

    Food allergy to the carbohydrate galactose-alpha-1,3-galactose (alpha-gal): four case reports and a review

    No full text
    Until recently, food allergies to mammalian meats have been considered to be very rare. The observation that patients not previously exposed to the monoclonal chimeric antibody cetuximab suffered from severe anaphylaxis upon first exposure, led to the identification of galactose-alpha-1,3-galactose as a new relevant carbohydrate allergen. These patients later often suffered from anaphylactic reactions to red meat. Epidemiological data indicated that bites by the tick Amblyomma americanum in the USA, later also by Ixodes species in other continents, resulted in sensitisation to alpha-gal. On the other hand, in African patients with parasitic disorders, a high prevalence of anti-alpha-gal IgE, without clinical relevance, has been reported. In our four cases, one patient with a late onset of meat allergy had a history of a tick bite. The other three patients had symptoms from childhood or at a juvenile age. This indicates that in some patients, other ways of sensitisation may also take place. However, in patients without atopy, tick bite-induced IgE to alpha-gal may be more relevant. Diagnosis is based on a history of delayed onset of anaphylaxis. Skin tests with commercially available meat test solutions are often equivocal or negative; skin tests with raw meat and particularly pork kidney are more sensitive. Determination of specific IgE to alpha-gal is commercially available. The highest sensitivity is observed with skin and basophil activation tests with cetuximab which is, however, limited by its high costs
    • 

    corecore