146 research outputs found
The Photoelectrochemistry of Assemblies of Semiconductor Nanoparticles at Interfaces
YesThe application of photoelectrochemical methods presents the researcher with a powerful set
of versatile tools by which photoactive materials, such as semiconductor quantum dots, at
conductive interfaces may be interrogated. While the range of photoelectrochemical
techniques available is quite large, it is surprising that very few have found their way into
common usage within the nanoparticle community. Here a number of photoelectrochemical
techniques and the principles upon which they are based are introduced. A short discussion
on the criticality of ensuring the nanoparticles are reliably anchored to the substrate is
followed by an introduction to the basic set of equipment required in order to enable the
investigator to undertake such experiments. Subsequently the four techniques of transient
photocurrent response to square wave illumination, photocurrent spectroscopy, intensity
modulated photocurrent spectroscopy (IMPS) and intensity modulated photovoltage
spectroscopy (IMVS) are introduced. Finally, the information that can be acquired using such
techniques is provided with emphasis being placed on a number of case studies exemplifying
the application of photoelectrochemical techniques to nanoparticles at interfaces, in particular
optically transparent electrodes
Recommended from our members
Type-I and Type-II Core-Shell Quantum Dots: Synthesis and Characterization
Ye
Using Petiole Analysis for Nitrogen Management in Cotton
4 pp., 3 figuresFor cotton growers, maintaining proper nitrogen balance is a major concern. Petiole analysis, the laboratory analysis of the nitrogen content of leaf stems, can be coupled with plant monitoring to form an effective nitrogen management program. This publication explains the causes of nitrogen deficiencies, sampling procedures, and how to use the laboratory analyses and interpret the results
Recommended from our members
Holistic process development to mitigate proteolysis of a subunit rotavirus vaccine candidate produced in Pichia pastoris by means of an acid pH pulse during fed-batch fermentation.
To meet the challenges of global health, vaccine design and development must be reconsidered to achieve cost of goods as low as 15¢ per dose. A new recombinant protein-based rotavirus vaccine candidate derived from non-replicative viral subunits fused to a P2 tetanus toxoid CD4(+) T cell epitope is currently under clinical development. We have sought to simplify the existing manufacturing process to meet these aims. To this end, we have taken a holistic process development approach to reduce process complexity and costs while producing a product with the required characteristics. We have changed expression system from Escherichia coli to Pichia pastoris, to produce a secreted product, thereby reducing the number of purification steps. However, the presence of proteases poses challenges to product quality. To understand the effect of fermentation parameters on product quality small-scale fermentations were carried out. Media pH and fermentation duration had the greatest impact on the proportion of full-length product. A novel acidic pH pulse strategy was used to minimize proteolysis, and this combined with an early harvest time significantly increased the proportion of full-length material (60-75%). An improved downstream process using a combination of CIEX and AIEX to further reduce proteases, resulted in maintaining product quality (95% yield)
A Close Companion Search Around L Dwarfs Using Aperture Masking Interferometry and Palomar Laser Guide Star Adaptive Optics
We present a close companion search around 16 known early L dwarfs using aperture masking interferometry with Palomar laser guide star adaptive optics (LGS AO). The use of aperture masking allows the detection of close binaries, corresponding to projected physical separations of 0.6-10.0 AU for the targets of our survey. This survey achieved median contrast limits of ΔK ~ 2.3 for separations between 1.2λ/D-4λ/D and ΔK ~ 1.4 at 2/3λ/D. We present four candidate binaries detected with moderate-to-high confidence (90%-98%). Two have projected physical separations less than 1.5 AU. This may indicate that tight-separation binaries contribute more significantly to the binary fraction than currently assumed, consistent with spectroscopic and photometric overluminosity studies. Ten targets of this survey have previously been observed with the Hubble Space Telescope as part of companion searches. We use the increased resolution of aperture masking to search for close or dim companions that would be obscured by full aperture imaging, finding two candidate binaries. This survey is the first application of aperture masking with LGS AO at Palomar. Several new techniques for the analysis of aperture masking data in the low signal-to-noise regime are explored
Absolute Energy Level Positions in CdSe Nanostructures from Potential-Modulated Absorption Spectroscopy (EMAS)
YesSemiconductor nanostructures like CdSe quantum dots and colloidal nanoplatelets
exhibit remarkable optical properties, making them interesting for applications in optoelectronics
and photocatalysis. For both areas of application a detailed understanding of
the electronic structure is essential to achieve highly efficient devices. The electronic
structure can be probed using the fact that optical properties of semiconductor nanoparticles
are found to be extremely sensitive to the presence of excess charges that can for
instance be generated by means of an electrochemical charge transfer via an electrode.
Here we present the use of potential modulated absorption spectroscopy (EMAS) as
a versatile spectroelectrochemical method to obtain absolute band edge positions of
CdSe nanostructures versus a well-defined reference electrode under ambient conditions.
In this the spectral properties of the nanoparticles are monitored dependent on an
applied electrochemical potential. We developed a bleaching model that yields the lowest
electronic state in the conduction band of the nanostructures. A change in the band
edge positions caused by quantum confinement is shown both for CdSe quantum dots as
well as for colloidal nanoplatelets. In the case of CdSe quantum dots these findings are
in good agreement with tight binding calculations. The method presented is not limited
to CdSe nanostructures but can be used as a universal tool. Hence, this technique allows
the determination of absolute band edge positions of a large variety of materials used in
various applications
The distribution and degradation of radiolabeled superparamagnetic iron oxide nanoparticles and quantum dots in mice
No(51)Cr-labeled, superparamagnetic, iron oxide nanoparticles ((51)Cr-SPIOs) and (65)Zn-labeled CdSe/CdS/ZnS-quantum dots ((65)Zn-Qdots) were prepared using an easy, on demand, exchange-labeling technique and their particokinetic parameters were studied in mice after intravenous injection. The results indicate that the application of these heterologous isotopes can be used to successfully mark the nanoparticles during initial distribution and organ uptake, although the (65)Zn-label appeared not to be fully stable. As the degradation of the nanoparticles takes place, the individual transport mechanisms for the different isotopes must be carefully taken into account. Although this variation in transport paths can bring new insights with regard to the respective trace element homeostasis, it can also limit the relevance of such trace material-based approaches in nanobioscience. By monitoring (51)Cr-SPIOs after oral gavage, the gastrointestinal non-absorption of intact SPIOs in a hydrophilic or lipophilic surrounding was measured in mice with such high sensitivity for the first time. After intravenous injection, polymer-coated, (65)Zn-Qdots were mainly taken up by the liver and spleen, which was different from that of ionic (65)ZnCl2. Following the label for 4 weeks, an indication of substantial degradation of the nanoparticles and the release of the label into the Zn pool was observed. Confocal microscopy of rat liver cryosections (prepared 2 h after intravenous injection of polymer-coated Qdots) revealed a colocalization with markers for Kupffer cells and liver sinusoidal endothelial cells (LSEC), but not with hepatocytes. In J774 macrophages, fluorescent Qdots were found colocalized with lysosomal markers. After 24 h, no signs of degradation could be detected. However, after 12 weeks, no fluorescent nanoparticles could be detected in the liver cryosections, which would confirm our (65)Zn data showing a substantial degradation of the polymer-coated CdSe/CdS/ZnS-Qdots in the liver
PALM-3000 high-order adaptive optics system for Palomar Observatory
Deployed as a multi-user shared facility on the 5.1 meter Hale Telescope at Palomar Observatory, the PALM-3000 highorder upgrade to the successful Palomar Adaptive Optics System will deliver extreme AO correction in the near-infrared, and diffraction-limited images down to visible wavelengths, using both natural and sodium laser guide stars. Wavefront control will be provided by two deformable mirrors, a 3368 active actuator woofer and 349 active actuator tweeter, controlled at up to 3 kHz using an innovative wavefront processor based on a cluster of 17 graphics processing units. A Shack-Hartmann wavefront sensor with selectable pupil sampling will provide high-order wavefront sensing, while an infrared tip/tilt sensor and visible truth wavefront sensor will provide low-order LGS control. Four back-end instruments are planned at first light: the PHARO near-infrared camera/spectrograph, the SWIFT visible light integral field spectrograph, Project 1640, a near-infrared coronagraphic integral field spectrograph, and 888Cam, a high-resolution visible light imager
The Magnitude of Androgen Receptor Positivity in Breast Cancer Is Critical for Reliable Prediction of Disease Outcome
Purpose: Consensus is lacking regarding the androgen receptor (AR) as a prognostic marker in breast cancer. The objectives of this study were to comprehensively review the literature on AR prognostication and determine optimal criteria for AR as an independent predictor of breast cancer survival. Experimental Design: AR positivity was assessed by immunostaining in two clinically validated primary breast cancer cohorts [training cohort, n = 219; validation cohort, n = 418; 77% and 79% estrogen receptor alpha (ERα) positive, respectively]. The optimal AR cut-point was determined by ROC analysis in the training cohort and applied to both cohorts. Results: AR was an independent prognostic marker of breast cancer outcome in 22 of 46 (48%) previous studies that performed multivariate analyses. Most studies used cut-points of 1% or 10% nuclear positivity. Herein, neither 1% nor 10% cut-points were robustly prognostic. ROC analysis revealed that a higher AR cut-point (78% positivity) provided optimal sensitivity and specificity to predict breast cancer survival in the training (HR, 0.41; P = 0.015) and validation (HR, 0.50; P = 0.014) cohorts. Tenfold cross-validation confirmed the robustness of this AR cut-point. Patients with ERα-positive tumors and AR positivity ≥78% had the best survival in both cohorts (P 0.87) had the best outcomes (P < 0.0001). Conclusions: This study defines an optimal AR cut-point to reliably predict breast cancer survival. Testing this cut-point in prospective cohorts is warranted for implementation of AR as a prognostic factor in the clinical management of breast cancer
- …