278 research outputs found

    Ares I-X Flight Test Philosophy

    Get PDF
    In response to the Vision for Space Exploration, the National Aeronautics and Space Administration (NASA) has defined a new space exploration architecture to return humans to the Moon and prepare for human exploration of Mars. One of the first new developments will be the Ares I Crew Launch Vehicle (CLV), which will carry the Orion Crew Exploration Vehicle (CEV), into Low Earth Orbit (LEO) to support International Space Station (ISS) missions and, later, support lunar missions. As part of Ares I development, NASA will perform a series of Ares I flight tests. The tests will provide data that will inform the engineering and design process and verify the flight hardware and software. The data gained from the flight tests will be used to certify the new Ares/Orion vehicle for human space flight. The primary objectives of this first flight test (Ares I-X) are the following: Demonstrate control of a dynamically similar integrated Ares CLV/Orion CEV using Ares CLV ascent control algorithms; Perform an in-flight separation/staging event between an Ares I-similar First Stage and a representative Upper Stage; Demonstrate assembly and recovery of a new Ares CLV-like First Stage element at Kennedy Space Center (KSC); Demonstrate First Stage separation sequencing, and quantify First Stage atmospheric entry dynamics and parachute performance; and Characterize the magnitude of the integrated vehicle roll torque throughout the First Stage (powered) flight. This paper will provide an overview of the Ares I-X flight test process and details of the individual flight tests

    Ares I-X Flight Test--The Future Begins Here

    Get PDF
    In less than two years, the National Aeronautics and Space Administration (NASA) will launch the Ares I-X mission. This will be the first flight of the Ares I crew launch vehicle, which, together with the Ares V cargo launch vehicle, will eventually send humans to the Moon, Mars, and beyond. As the countdown to this first Ares mission continues, personnel from across the Ares I-X Mission Management Office (MMO) are finalizing designs and fabricating vehicle hardware for a 2009 launch. This paper will discuss the hardware and programmatic progress of the Ares I-X mission

    The Application of Lean Thinking Principles and Kaizen Practices for the Successful Development and Implementation of the Ares I-X Flight Test Rocket and Mission

    Get PDF
    On October 28, 2009 the Ares I-X flight test rocket launched from Kennedy Space Center and flew its suborbital trajectory as designed. The mission was successfully completed as data from the test, and associated development activities were analyzed, transferred to stakeholders, and well documented. Positive lessons learned from Ares I-X were that the application of lean thinking principles and kaizen practices are effective in streamlining development activities. Ares I-X, like other historical rocket development projects, was hampered by technical, cost, and schedule challenges and if not addressed boldly could have resulted in cancellation of the test. The mission management team conducted nine major meetings, referred to as lean events, across its elements to assess plans, procedures, processes, requirements, controls, culture, organization, use of resources, and anything that could be changed to optimize schedule or reduce risk. The preeminent aspect of the lean events was the focus on value added activities and the removal or at least reduction in non-value activities. Trained Lean Six Sigma facilitators assisted the Ares I-X developers in conducting the lean events. They indirectly helped formulate the mission s own unique methodology for assessing schedule. A core team was selected to lead the events and report to the mission manager. Each activity leveraged specialized participants to analyze the subject matter and its related processes and then recommended alternatives and solutions. Stakeholders were the event champions. They empowered and encouraged the team to succeed. The keys to success were thorough preparation, honest dialog, small groups, adherence to the Ares I-X ground rules, and accountability through disciplined reporting and tracking of actions. This lean event formula was game-changing as demonstrated by the success of Ares I-X. It is highly recommended as a management tool to help develop other complex systems efficiently. The key benefits for Ares I-X were obtaining unambiguous schedule margin, defining enabling options for risk reduction, and most importantly a stronger more unified team

    A Systematic Review of Non-pharmacological Strategies to Reduce the Risk of Violence in Patients With Schizophrenia Spectrum Disorders in Forensic Settings

    Get PDF
    Background: The purpose of this systematic review is to systematically investigate which non-pharmacological interventions are effective in reducing violence risk among patients with schizophrenia spectrum disorders (SSD) in forensic settings. Methods: Six electronic data bases were searched. Two researchers independently screened 6,003 abstracts resulting in 143 potential papers. These were analyzed in detail by two independent researchers yielding 10 articles that could be used. Results: Of the 10 articles, four were non-randomized controlled trials, three were pre-post studies without controls, and one was observational. Only two studies applied a randomized controlled trial design. Cognitive behavioral treatment programs were investigated in three studies. A broad range of other interventions were studied. Often outcome measures were specific to each study and sample sizes were small. Frequently, important methodological information was missing from the papers. It was not possible to carry out a meta-analysis due to the heterogeneity of the study designs and outcome measures. Conclusion: Because of methodological limitations it is difficult to draw firm conclusions about the effectiveness of non-pharmacological interventions to reduce the risk of violence in patents with SSD in forensic psychiatry settings. Studies applying better methods in terms of study design, sample sizes and outcome measures are urgently needed

    Moisture susceptibility of high and low compaction dry process crumb rubber modified asphalt mixtures

    Get PDF
    The field performance of dry process crumb rubber-modified (CRM) asphalt mixtures has been reported to be inconsistent with stripping and premature cracking on the surfacing. One of the concerns is that, because achieving field compaction of CRM material is difficult due to the inherent resilient nature of the rubber particle, nonuniform field compaction may lead to a deficient bond between rubber and bitumen. To assess the influence of compaction, a series of CRM and control mixtures was produced and compacted at two levels: 4% (low, optimum laboratory compaction) and 8% (high, field experience) air void content. The long-term durability, in regard to moisture susceptibility of the mixtures, was assessed by conducting repeated moisture conditioning cycles. Mechanical properties (stiffness, fatigue, and resistance to permanent deformation) were determined in the Nottingham Asphalt Tester. Results indicated that compared with conventional mixtures, the CRM mixtures, regardless of compaction effort, are more susceptible to moisture with the degree of susceptibility primarily depending on the amount of rubber in the mixture, rather than the difference in compaction. This behavior is different from that of conventional mixtures in which, as expected, poorly compacted mixtures were found to be more susceptible to moisture than were well-compacted mixtures

    Evaluation of the prophylactic use of mitomycin-C to inhibit haze formation after photorefractive keratectomy in high myopia: a prospective clinical study

    Get PDF
    BACKGROUND: To study the effect of prophylactic application of mitomycin-C on haze formation in photorefractive keratectomy (PRK) for high myopia. METHODS: Fifty-four eyes of 28 myopic patients were enrolled in this prospective study. All eyes were operated by PRK followed by 0.02% mitomycin-C application for two minutes and washed with 20 ml normal saline afterwards. All eyes were examined thoroughly on the first 7 days and one month after surgery; 48 eyes (88.9%) at 3 and 6 months postoperatively. Hanna grading (in the scale of 0 to 4+) was used for assessment of corneal haze. RESULTS: The mean spherical equivalent refraction (SE) was -7.08 diopters (D) ± 1.11 (SD) preoperatively. Six months after surgery, 37 eyes (77.1%) achieved an uncorrected visual acuity (UCVA) of 20/20 or better, all eyes had a UCVA of 20/40 or better and 45 (93.7%) eyes had an SE within ± 1.00D. One month postoperatively, 2 eyes (3.7%) had grade 0.5+ of haze, while at 3 and 6 months after surgery no visited eye had haze at all. All eyes had a best corrected visual acuity (BCVA) of 20/40 or better and there were no lost lines in BCVA by 6 months after surgery. In spatial frequencies of 6 and 12 cycles per degree contrast sensitivity had decreased immediately after PRK and it had increased 1.5 lines by the 6(th )postoperative month compared to the preoperative data. CONCLUSIONS: The results show the efficacy of mitomycin-C in preventing corneal haze after treatment of high myopia with PRK. This method- PRK + mitomycin-C – can be considered an alternative treatment for myopic patients whose corneal thicknesses are inadequate for laser in situ keratomileusis (LASIK). However, the results should be confirmed in longer follow-ups

    In vivo biocompatibility assessment of (PTFE–PVDF–PP) terpolymer-based membrane with potential application for glaucoma treatment

    Get PDF
    The aim of the work was to evaluate the in vivo biological behaviour of polymeric membrane materials for glaucoma implants. The base material was biostable synthetic terpolymer (PTFE–PVDF–PP) with proved biocompability (PN-EN ISO 10993). The samples manufactured in the form a membrane were subjected to chemical and physical treatment to create an open pore system within the polymer matrix. As a porogenic phase biodegradable natrium alginate in a fibrous form was employed. The non-perforating deep sclerectomy technique was performed in a rabbit model. The clinical observations were made after 14 and 30 days. During the study clinical symptoms of a moderate degree were observed, and histopathological changes were typical for foreign body implantation. At the end stage of the study no significant difference in histopathological assessment was found between control and experimental group. Similarities observed in both groups and relatively mild histopathological changes in the tissue surrounding the implant indicate that the observed symptoms come from a deep scleral trauma caused by surgery, and not by the presence of the implant itself
    corecore