64 research outputs found

    Two-Tier Compensation Structures: Their Impact on Unions, Employers, and Employees

    Get PDF
    Martin conducted a study at a large company where its various wage tier systems allowed assessment of the long-term impact of tiers. Part of this study included the development of a survey designed to explore eight research questions related to tiers and to test five hypotheses of low-tier v. high-tier employees.https://research.upjohn.org/up_press/1102/thumbnail.jp

    Tuberculosis screening at a diabetes clinic in the Republic of the Marshall Islands

    Get PDF
    AbstractSettingTuberculosis (TB) and diabetes mellitus (DM) are prominent public health problems in the Republic of the Marshall Islands, a small island nation with high rates of tuberculosis and diabetes.ObjectiveEvaluate the rate of active and latent TB in a Pacific Island DM clinic.DesignIn one DM clinic on the island of Ebeye, 213 adult patients aged 27–86 years completed tuberculin skin testing and TB work-up between April 2010 and March 2012.ResultsScreening for TB led to the diagnosis of 77 patients with TB infection and 11 patients with TB disease. From these data, the prevalence of TB disease among DM patients in the clinic exceeded 5% (95% CI 2.2%–8.1%). All patients who completed TB screening were at high risk of TB disease, and those with DM aged ≀50 years had a higher risk of TB disease than those with DM over age 50 (RR 3.1, C.I. 1.0–9.7, p= 0.05).ConclusionThe experience at the Ebeye Diabetes Clinic demonstrates that screening DM patients for TB can identify significant rates of TB infection and TB disease, and should be considered for other settings with a high background TB incidence. Further assessment of TB risks should explore age, gender, and level of diabetes control

    Weak Lensing from Space I: Instrumentation and Survey Strategy

    Full text link
    A wide field space-based imaging telescope is necessary to fully exploit the technique of observing dark matter via weak gravitational lensing. This first paper in a three part series outlines the survey strategies and relevant instrumental parameters for such a mission. As a concrete example of hardware design, we consider the proposed Supernova/Acceleration Probe (SNAP). Using SNAP engineering models, we quantify the major contributions to this telescope's Point Spread Function (PSF). These PSF contributions are relevant to any similar wide field space telescope. We further show that the PSF of SNAP or a similar telescope will be smaller than current ground-based PSFs, and more isotropic and stable over time than the PSF of the Hubble Space Telescope. We outline survey strategies for two different regimes - a ``wide'' 300 square degree survey and a ``deep'' 15 square degree survey that will accomplish various weak lensing goals including statistical studies and dark matter mapping.Comment: 25 pages, 8 figures, 1 table, replaced with Published Versio

    Supernova / Acceleration Probe: A Satellite Experiment to Study the Nature of the Dark Energy

    Full text link
    The Supernova / Acceleration Probe (SNAP) is a proposed space-based experiment designed to study the dark energy and alternative explanations of the acceleration of the Universe's expansion by performing a series of complementary systematics-controlled measurements. We describe a self-consistent reference mission design for building a Type Ia supernova Hubble diagram and for performing a wide-area weak gravitational lensing study. A 2-m wide-field telescope feeds a focal plane consisting of a 0.7 square-degree imager tiled with equal areas of optical CCDs and near infrared sensors, and a high-efficiency low-resolution integral field spectrograph. The SNAP mission will obtain high-signal-to-noise calibrated light-curves and spectra for several thousand supernovae at redshifts between z=0.1 and 1.7. A wide-field survey covering one thousand square degrees resolves ~100 galaxies per square arcminute. If we assume we live in a cosmological-constant-dominated Universe, the matter density, dark energy density, and flatness of space can all be measured with SNAP supernova and weak-lensing measurements to a systematics-limited accuracy of 1%. For a flat universe, the density-to-pressure ratio of dark energy can be similarly measured to 5% for the present value w0 and ~0.1 for the time variation w'. The large survey area, depth, spatial resolution, time-sampling, and nine-band optical to NIR photometry will support additional independent and/or complementary dark-energy measurement approaches as well as a broad range of auxiliary science programs. (Abridged)Comment: 40 pages, 18 figures, submitted to PASP, http://snap.lbl.go

    Fabrication of the DESI corrector lenses

    Get PDF
    The Dark Energy Spectroscopic Instrument (DESI) is under construction to measure the expansion history of the Universe using the Baryon Acoustic Oscillation technique. The spectra of 35 million galaxies and quasars over 14000 square degrees will be measured during the life of the experiment. A new prime focus corrector for the KPNO Mayall telescope will deliver light to 5000 fiber optic positioners. The fibers in turn feed ten broad-band spectrographs. We describe the DESI corrector optics, a series of six fused silica and borosilicate lenses. The lens diameters range from 0.8 to 1.1 meters, and their weights 84 to 237 kg. Most lens surfaces are spherical, and two are challenging 10th-order polynomial aspheres. The lenses have been successfully polished and treated with an antireflection coating at multiple subcontractors, and are now being integrated into the DESI corrector barrel assembly at University College London. We describe the final performance of the lenses in terms of their various parameters, including surface figure, homogeneity, and others, and compare their final performance against the demanding DESI corrector requirements. Also we describe the reoptimization of the lens spacing in their corrector barrel after their final measurements are known. Finally we assess the performance of the corrector as a whole, compared to early budgeted estimates

    The Robotic Multiobject Focal Plane System of the Dark Energy Spectroscopic Instrument (DESI)

    Get PDF
    A system of 5020 robotic fiber positioners was installed in 2019 on the Mayall Telescope, at Kitt Peak National Observatory. The robots automatically retarget their optical fibers every 10-20 minutes, each to a precision of several microns, with a reconfiguration time of fewer than 2 minutes. Over the next 5 yr, they will enable the newly constructed Dark Energy Spectroscopic Instrument (DESI) to measure the spectra of 35 million galaxies and quasars. DESI will produce the largest 3D map of the universe to date and measure the expansion history of the cosmos. In addition to the 5020 robotic positioners and optical fibers, DESI’s Focal Plane System includes six guide cameras, four wave front cameras, 123 fiducial point sources, and a metrology camera mounted at the primary mirror. The system also includes associated structural, thermal, and electrical systems. In all, it contains over 675,000 individual parts. We discuss the design, construction, quality control, and integration of all these components. We include a summary of the key requirements, the review and acceptance process, on-sky validations of requirements, and lessons learned for future multiobject, fiber-fed spectrographs

    Different degrees of malnutrition and immunological alterations according to the aetiology of cirrhosis: a prospective and sequential study

    Get PDF
    OBJECTIVES: In this work we investigated how immunological dysfunction and malnutrition interact in alcoholic and viral aetiologies of cirrhosis. METHODS: To investigate the matter, 77 cirrhotic patients divided in three aetiologies [Alcohol, HCV and Alcohol + HCV) and 32 controls were prospectivelly and sequentially studied. Parameters of humoral immunity (Components 3 and 4 of seric complement and immunoglobulins A M, G and E) and of cellular immunity (total leukocytes and lymphocytes in peripheral blood, T lymphocytes subpopulations, CD4+ and CD8+, CD4+/CD8+ ratio and intradermic tests of delayed hypersensitivity), as well as nutrititional parameters: anthropometric measures, serum albumin and transferrin were evaluated. RESULTS: Multiple statistical comparisons showed that IgM was higher in HCV group; IgG was significantly elevated in both HCV and Alcohol + HCV, whereas for the Alcohol group, IgE was found at higher titles. The analysis of T- lymphocytes subpopulations showed no aetiologic differences, but intradermic tests of delayed hypersensitivity did show greater frequency of anergy in the Alcohol group. For anthropometric parameters, the Alcohol +HCV group displayed the lowest triceps skinfold whereas creatinine – height index evaluation was more preserved in the HCV group. Body mass index, arm muscle area and arm fat area showed that differently from alcohol group, the HCV group was similar to control. CONCLUSION: Significant differences were found among the main aetiologies of cirrhosis concerning immunological alterations and nutritional status: better nutrition and worse immunology for HCV and vice-versa for alcohol

    Broadband anti-reflection coating for the meter class Dark Energy Spectroscopic Instrument lenses

    Get PDF
    The Dark Energy Spectroscopic Instrument (DESI), currently under construction, will be used to measure the expansion history of the Universe using the Baryon Acoustic Oscillation technique. The spectra of 35 million galaxies and quasars over 14000 sq deg will be measured during the life of the experiment. A new prime focus corrector for the KPNO Mayall telescope will deliver light to 5000 fiber optic positioners. The fibers, in turn, feed ten broad-band spectrographs. We will describe the broadband AR coating (360 nm to 980nm) that was applied to the lenses of the camera system for DESI using ion assisted deposition techniques in a 3 m coating chamber. The camera has 6 lenses ranging in diameter from 0.8 m to 1.14 m, weighing from 84 kg to 237 kg and made from fused silica or BK7. The size and shape of the surfaces provided challenges in design, uniformity control, handling, tooling and process control. Single surface average transmission and minimum transmission met requirements. The varied optical surfaces and angle of incidence considerations meant the uniformity of the coating was of prime concern. The surface radius of curvature (ROC) for the 12 surfaces ranged from nearly flat to a ROC of 611 mm and a sag of 140 mm. One lens surface has an angle of incidence variation from normal incidence to 40°. Creating a design with a larger than required bandwidth to compensate for the non-uniformity and angle variation created the ability to reduce the required coating uniformity across the lens and a single design to be used for all common substrate surfaces. While a perfectly uniform coating is often the goal it is usually not practicable or cost effective for highly curved surfaces. The coating chamber geometry allowed multiple radial positions of the deposition sources as well as substrate height variability. Using these two variables we were able to avoid using any masking to achieve the uniformity required to meet radial and angle performance goals. Very broadband AR coatings usually have several very thin and optically important layers. The DESI coating design has layers approaching 3 nm in thickness. Having sensitive thin layers in the design meant controlling layer thickness and azimuthal variation were critical to manufacturing repeatability. Through use of strategically placed quartz crystal monitors combined with stable deposition plumes, the manufacturing variability was reduced to acceptable levels. Low deposition rates and higher rotation rates also provided some stability to azimuthal variation

    Clinical Trials in Head Injury

    Full text link
    Traumatic brain injury (TBI) remains a major public health problem globally. In the United States the incidence of closed head injuries admitted to hospitals is conservatively estimated to be 200 per 100,000 population, and the incidence of penetrating head injury is estimated to be 12 per 100,000, the highest of any developed country in the world. This yields an approximate number of 500,000 new cases each year, a sizeable proportion of which demonstrate signficant long-term disabilities. Unfortunately, there is a paucity of proven therapies for this disease. For a variety of reasons, clinical trials for this condition have been difficult to design and perform. Despite promising pre-clinical data, most of the trials that have been performed in recent years have failed to demonstrate any significant improvement in outcomes. The reasons for these failures have not always been apparent and any insights gained were not always shared. It was therefore feared that we were running the risk of repeating our mistakes. Recognizing the importance of TBI, the National Institute of Neurological Disorders and Stroke (NINDS) sponsored a workshop that brought together experts from clinical, research, and pharmaceutical backgrounds. This workshop proved to be very informative and yielded many insights into previous and future TBI trials. This paper is an attempt to summarize the key points made at the workshop. It is hoped that these lessons will enhance the planning and design of future efforts in this important field of research.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/63185/1/089771502753754037.pd
    • 

    corecore