234 research outputs found

    Development and validation of ester impregnated pH strips for locating nasogastric feeding tubes in the stomach-a multicentre prospective diagnostic performance study.

    Get PDF
    BACKGROUND: NG (nasogastric) tubes are used worldwide as a means to provide enteral nutrition. Testing the pH of tube aspirates prior to feeding is commonly used to verify tube location before feeding or medication. A pH at or lower than 5.5 was taken as evidence for stomach intubation. However, the existing standard pH strips lack sensitivity, especially in patients receiving feeding and antacids medication. We developed and validated a first-generation ester-impregnated pH strip test to improve the accuracy towards gastric placements in adult population receiving routine NG-tube feeding. The sensitivity was improved by its augmentation with the action of human gastric lipase (HGL), an enzyme specific to the stomach. METHODS: We carried out a multi-centred, prospective, two-gate diagnostic accuracy study on patients who require routine NG-tube feeding in 10 NHS hospitals comparing the sensitivity of the novel pH strip to the standard pH test, using either chest X-rays or, in its absence, clinical observation of the absence of adverse events as the reference standard. We also tested the novel pH strips in lung aspirates from patients undergoing oesophageal cancer surgeries using visual inspection as the reference standard. We simulated health economics using a decision analytic model and carried out adoption studies to understand its route to commercialisation. The primary end point is the sensitivity of novel and standard pH tests at the recommended pH cut-off of 5.5. RESULTS: A total of 6400 ester-impregnated pH strips were prepared based on an ISO13485 quality management system. A total of 376 gastric samples were collected from adult patients in 10 NHS hospitals who were receiving routine NG-tube feeding. The sensitivities of the standard and novel pH tests were respectively 49.2% (95% CI 44.1‑54.3%) and 70.2% (95% CI 65.6‑74.8%) under pH cut-off of 5.5 and the novel test has a lung specificity of 89.5% (95% CI 79.6%, 99.4%). Our simulation showed that using the novel test can potentially save 132 unnecessary chest X-rays per check per every 1000 eligible patients, or direct savings of £4034 to the NHS. CONCLUSIONS: The novel pH test correctly identified significantly more patients with tubes located inside the stomach compared to the standard pH test used widely by the NHS. TRIAL REGISTRATION: http://www.isrctn.com/ISRCTN11170249 , Registered 21 June 2017-retrospectively registered

    Pulsar Results with the Fermi Large Area Telescope

    Full text link
    The launch of the Fermi Gamma-ray Space Telescope has heralded a new era in the study of gamma-ray pulsars. The population of confirmed gamma-ray pulsars has gone from 6-7 to more than 60, and the superb sensitivity of the Large Area Telescope (LAT) on Fermi has allowed the detailed study of their spectra and light curves. Twenty-four of these pulsars were discovered in blind searches of the gamma-ray data, and twenty-one of these are, at present, radio quiet, despite deep radio follow-up observations. In addition, millisecond pulsars have been confirmed as a class of gamma-ray emitters, both individually and collectively in globular clusters. Recently, radio searches in the direction of LAT sources with no likely counterparts have been highly productive, leading to the discovery of a large number of new millisecond pulsars. Taken together, these discoveries promise a great improvement in the understanding of the gamma-ray emission properties and Galactic population of pulsars. We summarize some of the results stemming from these newly-detected pulsars and their timing and multi-wavelength follow-up observations.Comment: 21 pages, 9 figures, to appear in Proceedings of ICREA Workshop on The High-Energy Emission from Pulsars and their Systems, Sant Cugat, Spain, 2010 April 12-16 (Springer

    The ChromaTest, a digital color contrast sensitivity analyzer, for diabetic maculopathy: a pilot study

    Get PDF
    BACKGROUND: To assess the ability of the Chromatest in investigating diabetic maculopathy. METHOD: Patients with Type 2 diabetes and no concurrent ocular pathology or previous laser photocoagulation were recruited. Visual acuities were assessed followed by colour contrast sensitivity testing of each eye using Chromatest. Dilated fundoscopy with slit lamp biomicroscopy with 78 D lens was then performed to confirm the stage of diabetic retinopathy according to the Early Treatment Diabetic Retinopathy Study. RESULTS: 150 eyes in 150 patients were recruited into this study. 35 eyes with no previous laser photocoagulation were shown to have clinically significant macular oedema (CSMO) and 115 eyes with untreated non-proliferative diabetic retinopathy (NPDR) on fundus biomicroscopy. Statistical significant difference was found between CSMO and NPDR eyes for protan colour contrast threshold (p = 0.01). Statistical significance was found between CSMO and NPDR eyes for tritan colour contrast threshold (p = 0.0002). Sensitivity and specificity for screening of CSMO using pass-fail criterion for age matched TCCT results achieved 71% (95% confidence interval: 53-85%) and 70% (95% confidence interval: 60-78%), respectively. However, threshold levels were derived using the same data set for both training and testing the effectiveness since this was the first study of NPDR using the Chromatest CONCLUSION: The ChromaTest is a simple, cheap, easy to use, and quick test for colour contrast sensitivity. This study did not achieve results to justify use of the Chromatest for screening, but it reinforced the changes seen in tritan colour vision in diabetic retinopathy

    Safety and acceptability of an organic light-emitting diode sleep mask as a potential therapy for retinal disease

    Get PDF
    Purpose The purpose of the study was to study the effect of an organic light-emitting diode sleep mask on daytime alertness, wellbeing, and retinal structure/function in healthy volunteers and in diabetic macular oedema (DMO). Patients and methods Healthy volunteers in two groups, 18–30 yrs (A), 50–70 yrs (B) and people with DMO (C) wore masks (504 nm wavelength; 80 cd/m2 luminance; ≀8 h) nightly for 3 months followed by a 1-month recovery period. Changes from baseline were measured for (means): psychomotor vigilance task (PVT) (number of lapses (NL), response time (RT)), sleep, depression, psychological wellbeing (PW), visual acuity, contrast sensitivity, colour, electrophysiology, microperimetry, and retinal thickness on OCT. Results Of 60 participants, 16 (27%) withdrew, 8 (13%) before month 1, due to sleep disturbances and mask intolerance. About 36/55 (65%) who continued beyond month 1 reported ≄1 adverse event. At month 3 mean PVT worsened in Group A (RT (7.65%, P<0.001), NL (43.3%, P=0.005)) and mean PW worsened in all groups (A 28.0%, P=0.01, B 21.2%, P=0.03, C 12.8%, P<0.05). No other clinically significant safety signal was detected. Cysts reduced/resolved in the OCT subfield of maximal pathology in 67% Group C eyes. Thinning was greater at 3 and 4 months for greater baseline thickness (central subfield P<0.001, maximal P<0.05). Conclusion Sleep masks showed no major safety signal apart from a small impairment of daytime alertness and a moderate effect on wellbeing. Masks were acceptable apart from in some healthy participants. Preliminary data suggest a beneficial effect on retinal thickness in DMO. This novel therapeutic approach is ready for large clinical trials

    An Anti-Glitch in a Magnetar

    Get PDF
    Magnetars are neutron stars showing dramatic X-ray and soft Îł\gamma-ray outbursting behaviour that is thought to be powered by intense internal magnetic fields. Like conventional young neutron stars in the form of radio pulsars, magnetars exhibit "glitches" during which angular momentum is believed to be transferred between the solid outer crust and the superfluid component of the inner crust. Hitherto, the several hundred observed glitches in radio pulsars and magnetars have involved a sudden spin-up of the star, due presumably to the interior superfluid rotating faster than the crust. Here we report on X-ray timing observations of the magnetar 1E 2259+586 which we show exhibited a clear "anti-glitch" -- a sudden spin down. We show that this event, like some previous magnetar spin-up glitches, was accompanied by multiple X-ray radiative changes and a significant spin-down rate change. This event, if of origin internal to the star, is unpredicted in models of neutron star spin-down and is suggestive of differential rotation in the neutron star, further supporting the need for a rethinking of glitch theory for all neutron stars

    Liver transplantation for type I and type IV glycogen storage disease

    Get PDF
    Progressive liver failure or hepatic complications of the primary disease led to orthotopic liver transplantation in eight children with glycogen storage disease over a 9-year period. One patient had glycogen storage disease (GSD) type I (von Gierke disease) and seven patients had type IV GSD (Andersen disease). As previously reported [19], a 16.5-year-old-girl with GSD type I was successfully treated in 1982 by orthotopic liver transplantation under cyclosporine and steroid immunosuppression. The metabolic consequences of the disease have been eliminated, the renal function and size have remained normal, and the patient has lived a normal young adult life. A late portal venous thrombosis was treated successfully with a distal splenorenal shunt. Orthotopic liver transplantation was performed in seven children with type N GSD who had progressive hepatic failure. Two patients died early from technical complications. The other five have no evidence of recurrent hepatic amylopectinosis after 1.1–5.8 postoperative years. They have had good physical and intellectual maturation. Amylopectin was found in many extrahepatic tissues prior to surgery, but cardiopathy and skeletal myopathy have not developed after transplantation. Postoperative heart biopsies from patients showed either minimal amylopectin deposits as long as 4.5 years following transplantation or a dramatic reduction in sequential biopsies from one patient who initially had dense myocardial deposits. Serious hepatic derangement is seen most commonly in types T and IV GSD. Liver transplantation cures the hepatic manifestations of both types. The extrahepatic deposition of abnormal glycogen appears not to be problematic in type I disease, and while potentially more threatening in type IV disease, may actually exhibit signs of regression after hepatic allografting

    Fluticasone/formoterol combination therapy is as effective as fluticasone/salmeterol in the treatment of asthma, but has a more rapid onset of action: an open-label, randomized study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The inhaled corticosteroid (ICS) fluticasone propionate (fluticasone) and the long-acting ÎČ<sub>2</sub>-agonist (LABA) formoterol fumarate (formoterol) are being made available as a combination product (fluticasone/formoterol, <b><it>flutiform</it></b><sup>Âź</sup>) in a single aerosol inhaler. This 12-week, open-label, randomized, active-controlled, parallel-group, multicentre, phase 3 study compared the efficacy and safety of fluticasone/formoterol with the commercially available combination product fluticasone/salmeterol.</p> <p>Methods</p> <p>Patients aged ≄ 18 years (N = 202) with mild-to-moderate–severe, persistent asthma for ≄ 6 months prior to screening were included in the study. After a screening phase (4–10 days), eligible patients were randomized 1:1 to receive fluticasone/formoterol or fluticasone/salmeterol during the 12-week treatment period. The primary objective was to demonstrate non-inferiority of fluticasone/formoterol versus fluticasone/salmeterol, measured by pre-dose forced expiratory volume in the first second (FEV<sub>1</sub>), at week 12.</p> <p>Results</p> <p>Fluticasone/formoterol was comparable to fluticasone/salmeterol for the primary efficacy endpoint, mean pre-dose FEV<sub>1 </sub>at week 12. The new combination was also comparable to fluticasone/salmeterol for change from baseline to week 12 in pre-dose FEV<sub>1</sub>, change from pre-dose FEV<sub>1 </sub>at baseline to 2-hour post-dose FEV<sub>1 </sub>at week 12 and discontinuations due to lack of efficacy. Importantly, fluticasone/formoterol was superior to fluticasone/salmeterol in time to onset of action throughout the duration of the study. The two treatments demonstrated similar results for various other secondary efficacy parameters, including other lung function tests, patient-reported outcomes, rescue medication use, asthma exacerbations and Asthma Quality of Life Questionnaire scores. Fluticasone/formoterol was well tolerated and had a good safety profile that was similar to fluticasone/salmeterol.</p> <p>Conclusions</p> <p>The results of this study indicate that fluticasone/formoterol is as effective as fluticasone/salmeterol, and has a more rapid onset of action, reflecting the faster bronchodilatory effects of formoterol compared with those of salmeterol. If patients perceive the benefits of therapy with fluticasone/formoterol more rapidly than with fluticasone/salmeterol, this could have a positive impact on preference and adherence.</p> <p>Trial Registration</p> <p>ClinicalTrials.gov: <a href="http://www.clinicaltrials.gov/ct2/show/NCT00476073">NCT00476073</a></p

    A change in the optical polarization associated with a gamma-ray flare in the blazar 3C 279

    Get PDF
    It is widely accepted that strong and variable radiation detected over all accessible energy bands in a number of active galaxies arises from a relativistic, Doppler-boosted jet pointing close to our line of sight. The size of the emitting zone and the location of this region relative to the central supermassive black hole are, however, poorly known, with estimates ranging from light-hours to a light-year or more. Here we report the coincidence of a gamma-ray flare with a dramatic change of optical polarization angle. This provides evidence for co-spatiality of optical and gamma-ray emission regions and indicates a highly ordered jet magnetic field. The results also require a non-axisymmetric structure of the emission zone, implying a curved trajectory for the emitting material within the jet, with the dissipation region located at a considerable distance from the black hole, at about 10^5 gravitational radii.Comment: Published in Nature issued on 18 February 2010. Corresponding authors: Masaaki Hayashida and Greg Madejsk

    Varespladib and cardiovascular events in patients with an acute coronary syndrome: the VISTA-16 randomized clinical trial

    Get PDF
    IMPORTANCE: Secretory phospholipase A2(sPLA2) generates bioactive phospholipid products implicated in atherosclerosis. The sPLA2inhibitor varespladib has favorable effects on lipid and inflammatory markers; however, its effect on cardiovascular outcomes is unknown. OBJECTIVE: To determine the effects of sPLA2inhibition with varespladib on cardiovascular outcomes. DESIGN, SETTING, AND PARTICIPANTS: A double-blind, randomized, multicenter trial at 362 academic and community hospitals in Europe, Australia, New Zealand, India, and North America of 5145 patients randomized within 96 hours of presentation of an acute coronary syndrome (ACS) to either varespladib (n = 2572) or placebo (n = 2573) with enrollment between June 1, 2010, and March 7, 2012 (study termination on March 9, 2012). INTERVENTIONS: Participants were randomized to receive varespladib (500 mg) or placebo daily for 16 weeks, in addition to atorvastatin and other established therapies. MAIN OUTCOMES AND MEASURES: The primary efficacy measurewas a composite of cardiovascular mortality, nonfatal myocardial infarction (MI), nonfatal stroke, or unstable angina with evidence of ischemia requiring hospitalization at 16 weeks. Six-month survival status was also evaluated. RESULTS: At a prespecified interim analysis, including 212 primary end point events, the independent data and safety monitoring board recommended termination of the trial for futility and possible harm. The primary end point occurred in 136 patients (6.1%) treated with varespladib compared with 109 patients (5.1%) treated with placebo (hazard ratio [HR], 1.25; 95%CI, 0.97-1.61; log-rank P = .08). Varespladib was associated with a greater risk of MI (78 [3.4%] vs 47 [2.2%]; HR, 1.66; 95%CI, 1.16-2.39; log-rank P = .005). The composite secondary end point of cardiovascular mortality, MI, and stroke was observed in 107 patients (4.6%) in the varespladib group and 79 patients (3.8%) in the placebo group (HR, 1.36; 95% CI, 1.02-1.82; P = .04). CONCLUSIONS AND RELEVANCE: In patients with recent ACS, varespladib did not reduce the risk of recurrent cardiovascular events and significantly increased the risk of MI. The sPLA2inhibition with varespladib may be harmful and is not a useful strategy to reduce adverse cardiovascular outcomes after ACS. TRIAL REGISTRATION: clinicaltrials.gov Identifier: NCT01130246. Copyright 2014 American Medical Association. All rights reserved

    Concurrence of Danish Dementia and Cataract: Insights from the Interactions of Dementia Associated Peptides with Eye Lens α-Crystallin

    Get PDF
    Familial Danish Dementia (FDD) is an autosomal disease, which is distinguished by gradual loss of vision, deafness, progressive ataxia and dementia. Cataract is the first manifestation of the disease. In this article, we demonstrate a specific correlation between the poisoning of the chaperone activity of the rat eye lens α-crystallins, loss of lens transparency in organ culture by the pathogenic form of the Danish dementia peptide, i.e. the reduced Danish dementia peptide (redADan peptide), by a combination of ex vivo, in vitro, biophysical and biochemical techniques. The interaction of redADan peptide and lens crystallins are very specific when compared with another chaperone, HSP-70, underscoring the specificity of the pathogenic form of Danish dementia peptide, redADan, for the early onset of cataract in this disease
    • 

    corecore