1,341 research outputs found

    Effects of non-local exchange on core level shifts for gas-phase and adsorbed molecules

    Get PDF
    Density functional theory calculations are often used to interpret experimental shifts in core level binding energies. Calculations based on gradient-corrected (GC) exchange-correlation functionals are known to reproduce measured core level shifts (CLS) of isolated molecules and metal surfaces with reasonable accuracy. In the present study, we discuss a series of examples where the shifts calculated within a GC-functional significantly deviate from the experimental values, namely the CLS of C 1s in ethyl trifluoroacetate, Pd 3d in PdO and the O 1s shift for CO adsorbed on PdO(101). The deviations are traced to effects of the electronic self-interaction error with GC-functionals and substantially better agreements between calculated and measured CLS are obtained when a fraction of exact exchange is used in the exchange-correlation functional

    Recent advances in electronic structure theory and their influence on the accuracy of ab initio potential energy surfaces

    Get PDF
    Recent advances in electronic structure theory and the availability of high speed vector processors have substantially increased the accuracy of ab initio potential energy surfaces. The recently developed atomic natural orbital approach for basis set contraction has reduced both the basis set incompleteness and superposition errors in molecular calculations. Furthermore, full CI calculations can often be used to calibrate a CASSCF/MRCI approach that quantitatively accounts for the valence correlation energy. These computational advances also provide a vehicle for systematically improving the calculations and for estimating the residual error in the calculations. Calculations on selected diatomic and triatomic systems will be used to illustrate the accuracy that currently can be achieved for molecular systems. In particular, the F+H2 yields HF+H potential energy hypersurface is used to illustrate the impact of these computational advances on the calculation of potential energy surfaces

    Interactions of Ar(9+) and metastable Ar(8+) with a Si(100) surface at velocities near the image acceleration limit

    Full text link
    Auger LMM spectra and preliminary model simulations of Ar(9+) and metastable Ar(8+) ions interacting with a clean monocrystalline n-doped Si(100) surface are presented. By varying the experimental parameters, several yet undiscovered spectroscopic features have been observed providing valuable hints for the development of an adequate interaction model. On our apparatus the ion beam energy can be lowered to almost mere image charge attraction. High data acquisition rates could still be maintained yielding an unprecedented statistical quality of the Auger spectra.Comment: 34 pages, 11 figures, http://pikp28.uni-muenster.de/~ducree

    Measuring individual overpotentials in an operating solid-oxide electrochemical cell

    Full text link
    We use photo-electrons as a non-contact probe to measure local electrical potentials in a solid-oxide electrochemical cell. We characterize the cell in operando at near-ambient pressure using spatially-resolved X-ray photoemission spectroscopy. The overpotentials at the interfaces between the Ni and Pt electrodes and the yttria-stabilized zirconia (YSZ) electrolyte are directly measured. The method is validated using electrochemical impedance spectroscopy. Using the overpotentials, which characterize the cell's inefficiencies, we compare without ambiguity the electro-catalytic efficiencies of Ni and Pt, finding that on Ni H_2O splitting proceeds more rapidly than H2 oxidation, while on Pt, H2 oxidation proceeds more rapidly than H2O splitting.Comment: corrected; Phys. Chem. Chem. Phys., 201

    D-dimer and risk of thromboembolic and bleeding events in patients with atrial fibrillation - observations from the ARISTOTLE trial

    Get PDF
    BackgroundD-dimer is related to adverse outcomes in arterial and venous thromboembolic diseases. ObjectivesTo evaluate the predictive value of D-dimer level for stroke, other cardiovascular events, and bleeds, in patients with atrial fibrillation (AF) treated with oral anticoagulation with apixaban or warfarin; and to evaluate the relationship between the D-dimer levels at baseline and the treatment effect of apixaban vs. warfarin. MethodsIn the ARISTOTLE trial, 18201 patients with AF were randomized to apixaban or warfarin. D-dimer was analyzed in 14878 patients at randomization. The cohort was separated into two groups; not receiving vitaminK antagonist (VKA) treatment and receiving VKA treatment at randomization. ResultsHigher D-dimer levels were associated with increased frequencies of stroke or systemic embolism (hazard ratio [HR][Q4 vs. Q1]1.72, 95% confidence interval [CI]1.14-2.59, P=0.003), death (HR[Q4 vs. Q1]4.04, 95%CI3.06-5.33) and major bleeding (HR[Q4 vs. Q1]2.47, 95%CI1.77-3.45,

    High energy photoelectron diffraction: model calculations and future possibilities

    Get PDF
    We discuss the theoretical modelling of x-ray photoelectron diffraction (XPD) with hard x-ray excitation at up to 20 keV, using the dynamical theory of electron diffraction to illustrate the characteristic aspects of diffraction patterns resulting from such localized emission sources in a multi-layer crystal. We show via dynamical calculations for diamond, Si, and Fe that the dynamical theory well predicts available current data for lower energies around 1 keV, and that the patterns for energies above about 1 keV are dominated by Kikuchi bands which are created by the dynamical scattering of electrons from lattice planes. The origin of the fine structure in such bands is discussed from the point of view of atomic positions in the unit cell. The profiles and positions of the element-specific photoelectron Kikuchi bands are found to be sensitive to lattice distortions (e.g. a 1% tetragonal distortion) and the position of impurities or dopants with respect to lattice sites. We also compare the dynamical calculations to results from a cluster model that is more often used to describe lower-energy XPD. We conclude that hard XPD (HXPD) should be capable of providing unique bulk-sensitive structural information for a wide variety of complex materials in future experiments.Comment: 29 pages, 13 figure

    Repeated Measurements of Cardiac Biomarkers in Atrial Fibrillation and Validation of the ABC Stroke Score Over Time

    Get PDF
    Background--Cardiac biomarkers are independent risk markers in atrial fibrillation, and the novel biomarker-based ABC stroke score (age, biomarkers, and clinical history of prior stroke) was recently shown to improve the prediction of stroke risk in patients with atrial fibrillation. Our aim was to investigate the short-term variability of the cardiac biomarkers and evaluate whether the ABC stroke risk score provides a stable short- term risk estimate. Methods and Results--According to the study protocol, samples were obtained at entry and also at 2 months in 4796 patients with atrial fibrillation followed for a median of 1.8 years in the ARISTOTLE (Apixaban for Reduction in Stroke and Other Thromboembolic Events in Atrial Fibrillation) trial. Cardiac troponin I, cardiac troponin T, and N-terminal pro-B-type natriuretic peptide were measured with high-sensitivity immunoassays. Associations with outcomes were evaluated by Cox regression. C indices and calibration plots were used to evaluate the ABC stroke score at 2 months. The average changes in biomarker levels during 2 months were small ( median change cardiac troponin T +2.8%, troponin I +2.0%, and N-terminal pro-B-type natriuretic peptide +13.5%) and within-subject correlation was high ( all >= 0.82). Repeated measurement of cardiac biomarkers provided some incremental prognostic value for mortality but not for stroke when combined with clinical risk factors and baseline levels of the biomarkers. Based on 8702 person-years of follow-up and 96 stroke/systemic embolic events, the ABC stroke score at 2 months achieved a similar C index of 0.70 (95% CI, 0.65-0.76) as compared with 0.70 (95% CI, 0.65-0.75) at baseline. The ABC stroke score remained well calibrated using predefined risk classes. Conclusions--In patients with stable atrial fibrillation, the variability of the cardiac biomarkers and the biomarker- based ABC stroke score during 2 months are small. The prognostic information by the ABC stroke score remains consistent and well calibrated with similar good predictive performance if patients are retested after 2 months. Clinical Trial Registration --URL: http://www.clinicaltrials.gov. Unique identifier: NCT00412984.Peer reviewe
    corecore