167 research outputs found

    The impact of post-procedural complications on reimbursement, length of stay and mechanical ventilation among patients undergoing transcatheter aortic valve implantation in Germany

    Get PDF
    BACKGROUND: The impact of various post-procedural complications after transcatheter aortic valve implantation (TAVI) on resource use and their consequences in the German reimbursement system has still not been properly quantified. METHODS: In a retrospective observational study, we use data from the German DRG statistic on patient characteristics and in-hospital outcomes of all isolated TAVI procedures in 2013 (N = 9147). The impact of post-procedural complications on reimbursement, length of stay and mechanical ventilation was analyzed using both unadjusted and risk-adjusted linear and logistic regression analyses. RESULTS: A total of 235 (2.57%) strokes, 583 (6.37%) bleeding events, 474 (5.18%) cases of acute kidney injury and 1428 (15.61%) pacemaker implantations were documented. The predicted reimbursement of an uncomplicated TAVI procedure was €33,272, and bleeding events were associated with highest additional reimbursement (€12,839, p 48 h: OR 6.93, p 48 h: OR 5.73, p < 0.001). Pacemaker implantations, in contrast, were associated with comparably small increases in reimbursement (€662, p = 0.006) and length of stay (3.54 days, p = 0.006) and no impaired likelihood of mechanical ventilation more than 48 h (OR 1.22, p = 0.156). Interestingly, these complication-related consequences remain mostly unchanged after baseline risk-adjustment. CONCLUSIONS: Post procedural complications such as bleeding events, acute kidney injuries and strokes are associated with increased resource use and substantial amounts of additional reimbursement in Germany, which has important implications for decision making outside of the usual clinical sphere

    Test-retest repeatability of child's respiratory symptoms and perceived indoor air quality - comparing self-and parent-administered questionnaires

    Get PDF
    Background: Questionnaires can be used to assess perceived indoor air quality and symptoms in schools. Questionnaires for primary school aged children have traditionally been parent-administered, but self-administered questionnaires would be easier to administer and may yield as good, if not better, information. Our aim was to compare the repeatability of self- and parent-administered indoor air questionnaires designed for primary school aged pupils. Methods: Indoor air questionnaire with questions on child's symptoms and perceived indoor air quality in schools was sent to parents of pupils aged 7-12 years in two schools and again after two weeks. Slightly modified version of the questionnaire was administered to pupils aged 9-12 years in another two schools and repeated after a week. 351 (52%) parents and 319 pupils (86%) answered both the first and the second questionnaire. Test-retest repeatability was assessed with intra-class correlation (ICC) and Cohen's kappa coefficients (k). Results: Test-retest repeatability was generally between 0.4-0.7 (ICC; k) in both self-and parent-administered questionnaire. In majority of the questions on symptoms and perceived indoor air quality test-retest repeatability was at the same level or slightly better in self-administered compared to parent-administered questionnaire. Agreement of self-and parent administered questionnaires was generally <0.4 (ICC; k) in reported symptoms and 0.4-0.6 (ICC; k) in perceived indoor air quality. Conclusions: Children aged 9-12 years can give as, or even more, repeatable information about their respiratory symptoms and perceived indoor air quality than their parents. Therefore, it may be possible to use self-administered questionnaires in future studies also with children.Peer reviewe

    PET/CT without capacity limitations: a Danish experience from a European perspective

    Get PDF
    # The Author(s) 2011. This article is published with open access at Springerlink.com Objectives We report the 3-year clinical experience of a large new Danish PET/CT centre without capacity limitations in relation to national and European developments. Methods The use of PET/CT in cancer was registered from early 2006 to early 2009 to judge the impact on patient management and to compare it with national and European trends. Results 6056 PET/CT examinations were performed in 4327 patients. Activity increased by 86 examinations per month compared with the same month the year before. Referrals came primarily from oncology (23.0%), haematology (21.6%), surgery (12.6%), internal medicine (12.7%) and gynaecology (5.5%). Referral indications were diagnosis (31.3%), staging (22.3%), recurrence detection (21.2%), response evaluation (17.0%) and other (8.2%). Response from nearly 60 % of users showed that PET/CT caused a change in diagnosis and/or staging and/or treatment plan in 36.0 % of cases. During the study period, there was a steep increase in the national use of FDG and in the European use of PET/CT. Conclusions We recorded a constantly increasing use of PET/CT that caused a change in diagnosis and/or stagin

    The Patient Health Questionnaire-9 for detection of major depressive disorder in primary care: consequences of current thresholds in a crosssectional study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>There is a need for brief instruments to ascertain the diagnosis of major depressive disorder. In this study, we present the reliability, construct validity and accuracy of the PHQ-9 and PHQ-2 to detect major depressive disorder in primary care.</p> <p>Methods</p> <p>Cross-sectional analyses within a large prospective cohort study (PREDICT-NL). Data was collected in seven large general practices in the centre of the Netherlands. 1338 subjects were recruited in the general practice waiting room, irrespective of their presenting complaint. The diagnostic accuracy (the area under the ROC curve and sensitivities and specificities for various thresholds) was calculated against a diagnosis of major depressive disorder determined with the Composite International Diagnostic Interview (CIDI).</p> <p>Results</p> <p>The PHQ-9 showed a high degree of internal consistency (ICC = 0.88) and test-retest reliability (correlation = 0.94). With respect to construct validity, it showed a clear association with functional status measurements, sick days and number of consultations. The discriminative ability was good for the PHQ-9 (area under the ROC curve = 0.87, 95% CI: 0.84-0.90) and the PHQ-2 (ROC area = 0.83, 95% CI 0.80-0.87). Sensitivities at the recommended thresholds were 0.49 for the PHQ-9 at a score of 10 and 0.28 for a categorical algorithm. Adjustment of the threshold and the algorithm improved sensitivities to 0.82 and 0.84 respectively but the specificity decreased from 0.95 to 0.82 (threshold) and from 0.98 to 0.81 (algorithm). Similar results were found for the PHQ-2: the recommended threshold of 3 had a sensitivity of 0.42 and lowering the threshold resulted in an improved sensitivity of 0.81.</p> <p>Conclusion</p> <p>The PHQ-9 and the PHQ-2 are useful instruments to detect major depressive disorder in primary care, provided a high score is followed by an additional diagnostic work-up. However, often recommended thresholds for the PHQ-9 and the PHQ-2 resulted in many undetected major depressive disorders.</p

    Posters display III clinical outcome and PET

    Get PDF

    TESS Delivers Five New Hot Giant Planets Orbiting Bright Stars From The Full-Frame Images

    Get PDF
    We present the discovery and characterization of five hot and warm Jupiters—TOI-628 b (TIC 281408474; HD 288842), TOI-640 b (TIC 147977348), TOI-1333 b (TIC 395171208, BD+47 3521A), TOI-1478 b (TIC 409794137), and TOI-1601 b (TIC 139375960)—based on data from NASA\u27s Transiting Exoplanet Survey Satellite (TESS). The five planets were identified from the full-frame images and were confirmed through a series of photometric and spectroscopic follow-up observations by the TESS Follow-up Observing Program Working Group. The planets are all Jovian size (RP = 1.01–1.77 RJ) and have masses that range from 0.85 to 6.33 MJ. The host stars of these systems have F and G spectral types (5595 ≤ Teff ≤ 6460 K) and are all relatively bright (9.5 \u3c V \u3c 10.8, 8.2 \u3c K \u3c 9.3), making them well suited for future detailed characterization efforts. Three of the systems in our sample (TOI-640 b, TOI-1333 b, and TOI-1601 b) orbit subgiant host stars (log\mathrm{log} g \u3c 4.1). TOI-640 b is one of only three known hot Jupiters to have a highly inflated radius (RP \u3e 1.7 RJ, possibly a result of its host star\u27s evolution) and resides on an orbit with a period longer than 5 days. TOI-628 b is the most massive, hot Jupiter discovered to date by TESS with a measured mass of 6.31−0.30+0.28{6.31}_{-0.30}^{+0.28}MJ and a statistically significant, nonzero orbital eccentricity of e = 0.074−0.022+0.021{0.074}_{-0.022}^{+0.021}. This planet would not have had enough time to circularize through tidal forces from our analysis, suggesting that it might be remnant eccentricity from its migration. The longest-period planet in this sample, TOI-1478 b (P = 10.18 days), is a warm Jupiter in a circular orbit around a near-solar analog. NASA\u27s TESS mission is continuing to increase the sample of well-characterized hot and warm Jupiters, complementing its primary mission goals

    Erratum to: Methods for evaluating medical tests and biomarkers

    Get PDF
    [This corrects the article DOI: 10.1186/s41512-016-0001-y.]
    • …
    corecore