131 research outputs found

    On the use of uavs in mining and archaeology - geo-accurate 3d reconstructions using various platforms and terrestrial views

    Get PDF
    During the last decades photogrammetric computer vision systems have been well established in scientific and commercial applications. Especially the increasing affordability of unmanned aerial vehicles (UAVs) in conjunction with automated multi-view processing pipelines have resulted in an easy way of acquiring spatial data and creating realistic and accurate 3D models. With the use of multicopter UAVs, it is possible to record highly overlapping images from almost terrestrial camera positions to oblique and nadir aerial images due to the ability to navigate slowly, hover and capture images at nearly any possible position. Multi-copter UAVs thus are bridging the gap between terrestrial and traditional aerial image acquisition and are therefore ideally suited to enable easy and safe data collection and inspection tasks in complex or hazardous environments. In this paper we present a fully automated processing pipeline for precise, metric and geo-accurate 3D reconstructions of complex geometries using various imaging platforms. Our workflow allows for georeferencing of UAV imagery based on GPS-measurements of camera stations from an on-board GPS receiver as well as tie and control point information. Ground control points (GCPs) are integrated directly in the bundle adjustment to refine the georegistration and correct for systematic distortions of the image block. We discuss our approach based on three different case studies for applications in mining and archaeology and present several accuracy related analyses investigating georegistration, camera network configuration and ground sampling distance. Our approach is furthermore suited for seamlessly matching and integrating images from different view points and cameras (aerial and terrestrial as well as inside views) into one single reconstruction. Together with aerial images from a UAV, we are able to enrich 3D models by combining terrestrial images as well inside views of an object by joint image processing to generate highly detailed, accurate and complete reconstructions

    ON THE USE OF UAVS IN MINING AND ARCHAEOLOGY - GEO-ACCURATE 3D RECONSTRUCTIONS USING VARIOUS PLATFORMS AND TERRESTRIAL VIEWS

    Get PDF
    During the last decades photogrammetric computer vision systems have been well established in scientific and commercial applications. Especially the increasing affordability of unmanned aerial vehicles (UAVs) in conjunction with automated multi-view processing pipelines have resulted in an easy way of acquiring spatial data and creating realistic and accurate 3D models. With the use of multicopter UAVs, it is possible to record highly overlapping images from almost terrestrial camera positions to oblique and nadir aerial images due to the ability to navigate slowly, hover and capture images at nearly any possible position. Multi-copter UAVs thus are bridging the gap between terrestrial and traditional aerial image acquisition and are therefore ideally suited to enable easy and safe data collection and inspection tasks in complex or hazardous environments. In this paper we present a fully automated processing pipeline for precise, metric and geo-accurate 3D reconstructions of complex geometries using various imaging platforms. Our workflow allows for georeferencing of UAV imagery based on GPS-measurements of camera stations from an on-board GPS receiver as well as tie and control point information. Ground control points (GCPs) are integrated directly in the bundle adjustment to refine the georegistration and correct for systematic distortions of the image block. We discuss our approach based on three different case studies for applications in mining and archaeology and present several accuracy related analyses investigating georegistration, camera network configuration and ground sampling distance. Our approach is furthermore suited for seamlessly matching and integrating images from different view points and cameras (aerial and terrestrial as well as inside views) into one single reconstruction. Together with aerial images from a UAV, we are able to enrich 3D models by combining terrestrial images as well inside views of an object by joint image processing to generate highly detailed, accurate and complete reconstructions

    Comparing chromosomal and mitochondrial phylogenies of the Indriidae (Primates, Lemuriformes)

    Get PDF
    The Malagasy primate family Indriidae comprises three genera with up to 19 species. Cytogenetic and molecular phylogenies of the Indriidae have been performed with special attention to the genus Propithecus. Comparative R-banding and FISH with human paints were applied to karyotypes of representatives of all three genera and confirmed most of the earlier R-banding results. However, additional chromosomal rearrangements were detected. A reticulated and a cladistic phylogeny, the latter including hemiplasies, have been performed. Cladistic analysis of cytogenetic data resulted in a phylogenetic tree revealing (1) monophyly of the family Indriidae, (2) monophyly of the genus Avahi, (3) sister–group relationships between Propithecus diadema and Propithecus edwardsi, and (4) the grouping of the latter with Indri indri, Propithecus verreauxi, and Propithecus tattersalli, and thus suggesting paraphyly of the genus Propithecus. A molecular phylogeny based on complete mitochondrial cytochrome b sequences of 16 species indicated some identical relationships, such as the monophyly of Avahi and the sister–group relationships of the eastern (P. diadema and P. edwardsi) to the western Propithecus species (P. verreauxi, Propithecus coquereli, and P. tattersalli). However, the main difference between the molecular and cytogenetic phylogenies consists in an early divergence of Indri in the molecular phylogeny while in the chromosomal phylogeny it is nested within Propithecus. The similarities and differences between molecular and cytogenetic phylogenies in relation to data on the species’ geographic distributions and mating systems allow us to propose a scenario of the evolution of Indriidae. Chromosomal and molecular processes alone or in combination created a reproductive barrier that was then followed by further speciation processes

    Comparison of two different physical activity monitors

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Understanding the relationships between physical activity (PA) and disease has become a major area of research interest. Activity monitors, devices that quantify free-living PA for prolonged periods of time (days or weeks), are increasingly being used to estimate PA. A range of different activity monitors brands are available for investigators to use, but little is known about how they respond to different levels of PA in the field, nor if data conversion between brands is possible.</p> <p>Methods</p> <p>56 women and men were fitted with two different activity monitors, the Actigraph™ (Actigraph LLC; AGR) and the Actical™ (Mini-Mitter Co.; MM) for 15 days. Both activity monitors were fixed to an elasticized belt worn over the hip, with the anterior and posterior position of the activity monitors randomized. Differences between activity monitors and the validity of brand inter-conversion were measured by <it>t</it>-tests, Pearson correlations, Bland-Altman plots, and coefficients of variation (CV).</p> <p>Results</p> <p>The AGR detected a significantly greater amount of daily PA (216.2 ± 106.2 vs. 188.0 ± 101.1 counts/min, P < 0.0001). The average difference between activity monitors expressed as a CV were 3.1 and 15.5% for log-transformed and raw data, respectively. When a conversion equation was applied to convert datasets from one brand to another, the differences were no longer significant, with CV's of 2.2 and 11.7%, log-transformed and raw data, respectively.</p> <p>Conclusion</p> <p>Although activity monitors predict PA on the same scale (counts/min), the results between these two brands are not directly comparable. However, the data are comparable if a conversion equation is applied, with better results for log-transformed data.</p

    Analysis of differential gene expression in human melanocytic tumour lesions by custom made oligonucleotide arrays

    Get PDF
    Melanoma is one of the most aggressive types of cancer and resection of the tumour prior to dissemination of tumour cells is still the most effective treatment. Therefore, early diagnosis of melanocytic lesions is important and identification of novel (molecular) markers would be helpful to improve diagnosis. Moreover, better understanding of molecular targets involved in melanocytic tumorigenesis could possibly lead to development of novel interventions. In this study, we used a custom made oligonucleotide array containing 298 genes that were previously found to be differentially expressed in human melanoma cell lines 1F6 (rarely metastasising) and Mel57 (frequently metastasising). We determined differential gene expression in human common nevocellular nevus and melanoma metastasis lesions. By performing nine dye-swap array experiments, using individual as well as pooled melanocytic lesions, a constant differential expression could be detected for 25 genes in eight out of nine or nine out of nine array analyses. For at least nine of these genes, namely THBD, FABP7, H2AFJ, RRAGD, MYADM, HR, CKS2, NCK2 and GDF15, the differential expression found by array analyses could be verified by semiquantitative and/or real-time quantitative RT–PCR. The genes that we identified to be differentially expressed during melanoma progression could be potent targets for diagnostic, prognostic and/or therapeutic interventions

    How Linear Tension Converts to Curvature: Geometric Control of Bone Tissue Growth

    Get PDF
    This study investigated how substrate geometry influences in-vitro tissue formation at length scales much larger than a single cell. Two-millimetre thick hydroxyapatite plates containing circular pores and semi-circular channels of 0.5 mm radius, mimicking osteons and hemi-osteons respectively, were incubated with MC3T3-E1 cells for 4 weeks. The amount and shape of the tissue formed in the pores, as measured using phase contrast microscopy, depended on the substrate geometry. It was further demonstrated, using a simple geometric model, that the observed curvature-controlled growth can be derived from the assembly of tensile elements on a curved substrate. These tensile elements are cells anchored on distant points of the curved surface, thus creating an actin “chord” by generating tension between the adhesion sites. Such a chord model was used to link the shape of the substrate to cell organisation and tissue patterning. In a pore with a circular cross-section, tissue growth increases the average curvature of the surface, whereas a semi-circular channel tends to be flattened out. Thereby, a single mechanism could describe new tissue growth in both cortical and trabecular bone after resorption due to remodelling. These similarities between in-vitro and in-vivo patterns suggest geometry as an important signal for bone remodelling

    Moderate alcohol consumption increases insulin sensitivity and ADIPOQ expression in postmenopausal women: a randomised, crossover trial

    Get PDF
    Aims/hypothesis To determine whether 6 weeks of daily, moderate alcohol consumption increases expression of the gene encoding adiponectin (ADIPOQ) and plasma levels of the protein, and improves insulin sensitivity in postmenopausal women. Methods In a randomised, open-label, crossover trial conducted in the Netherlands, 36 apparently healthy postmenopausal women who were habitual alcohol consumers, received 250 ml white wine (~25 g alcohol/day) or 250 ml of white grape juice (control) daily during dinner for 6 weeks. Randomisation to treatment allocation occurred according to BMI. Insulin sensitivity and ADIPOQ mRNA and plasma adiponectin levels were measured at the end of both periods. Insulin sensitivity was estimated using the homeostasis model assessment of insulin resistance (HOMA-IR). Levels of ADIPOQ mRNA in subcutaneous adipose tissue were determined by RT-PCR. Results All subjects completed the study. Six weeks of white wine consumption reduced fasting insulin (mean¿±¿SEM 40.0¿±¿3.4 vs 46.5¿±¿3.4 pmol/l; p

    Estimates of adherence and error analysis of physical activity data collected via accelerometry in a large study of free-living adults

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Activity monitors (AM) are small, electronic devices used to quantify the amount and intensity of physical activity (PA). Unfortunately, it has been demonstrated that data loss that occurs when AMs are not worn by subjects (removals during sleeping and waking hours) tend to result in biased estimates of PA and total energy expenditure (TEE). No study has reported the degree of data loss in a large study of adults, and/or the degree to which the estimates of PA and TEE are affected. Also, no study in adults has proposed a methodology to minimize the effects of AM removals.</p> <p>Methods</p> <p>Adherence estimates were generated from a pool of 524 women and men that wore AMs for 13 – 15 consecutive days. To simulate the effect of data loss due to AM removal, a reference dataset was first compiled from a subset consisting of 35 highly adherent subjects (24 HR; minimum of 20 hrs/day for seven consecutive days). AM removals were then simulated during sleep and between one and ten waking hours using this 24 HR dataset. Differences in the mean values for PA and TEE between the 24 HR reference dataset and the different simulations were compared using paired <it>t</it>-tests and/or coefficients of variation.</p> <p>Results</p> <p>The estimated average adherence of the pool of 524 subjects was 15.8 ± 3.4 hrs/day for approximately 11.7 ± 2.0 days. Simulated data loss due to AM removals during sleeping hours in the 24 HR database (n = 35), resulted in biased estimates of PA (p < 0.05), but not TEE. Losing as little as one hour of data from the 24 HR dataset during waking hours results in significant biases (p < 0.0001) and variability (coefficients of variation between 7 and 21%) in the estimates of PA. Inserting a constant value for sleep and imputing estimates for missing data during waking hours significantly improved the estimates of PA.</p> <p>Conclusion</p> <p>Although estimated adherence was good, measurements of PA can be improved by relatively simple imputation of missing AM data.</p
    corecore