2,319 research outputs found
Development of an IoT solution for detergent supervision in industrial washing machines
Dupla diplomação dom a UTFPR - Universidade Tecnológica Federal do ParanáAutomation of industrial activities aim to improve the efficiency of the productive processes
while reducing costs and increasing safety. In industrial laundries, the detergent
level measurement is a key element for asset management, mainly due to the necessity
of maintaining a continuous flow of washing processes. Therefore, this work presents a
solution implemented in the industrial laundry reservoirs of Santa Casa da Misericórdia
de Bragança, in Portugal, using an Internet of Things (IoT) approach, which integrates
a Wi-Fi based measurement system, capable of monitoring and recording the detergent
liquid level from reservoirs in real-time. Thereby, a microcontrolled system was developed
to perform level measurements using an ultrasonic sensor, in which data is sent to a
database and, through a web based platform, the client can remotely access the measurement
results. In order to facilitate the physical installation of the developed hardware in
the existent setup, a custom-made enclosure was designed and 3D printed.A automação das atividades industriais tem como objetivo melhorar a eficiência de processos
produtivos, reduzindo custos e aumentando a segurança. Em lavanderias industriais,
a medição de nível de detergente líquido é um elemento fundamental para o gerenciamento
de ativos, principalmente devido à necessidade de manter um fluxo contínuo dos
processos de lavagem. Dessa forma, o trabalho apresenta uma solução implementada nos
reservatórios da lavanderia industrial da Santa Casa da Misericórdia de Bragança, em
Portugal, usando uma abordagem de internet das coisas, na qual integra um sistema de
medição com conexão Wi-Fi, capaz de monitorar e registrar o nível de detergente líquido
dos reservatórios em tempo real. Com isso, foi desenvolvido um sistema microcontrolado
responsável por realizar as medições de nível ulilizando sensor ultrasônico, na qual os
dados são enviados para um banco de dados e, através de uma plataforma web, o cliente
consiga acessar de forma remota o resultado das medições. Para facilitar a instalação do
sistema nos reservatórios, um bujão foi desenhado sob medida e impresso em 3D
INTRODUCCIÓN: SABER Y PODER EN LA PERIFERIA DE OCCIDENTE
Consejo Nacl Invest Cient & Tecn, RA-1033 Buenos Aires, DF, ArgentinaUniversidade Federal de São Paulo, UNIFESP, São Paulo, BrazilUniversidade Federal de São Paulo, UNIFESP, São Paulo, BrazilWeb of Scienc
MICRO PHOTO IONIZATION DETECTOR FOR BTEX ANALYSIS: REVIEW REPORT OF PERFORMANCE INFLUENCING PARAMETERS
International audienceVolatile Organic Compounds (VOCs) are gaseous chemical species emitted from solids and liquids that may cause short and long term adverse health effects. They are present in both outdoor and indoor air. In open environments, automotive exhausts and industrial waste are major sources of VOCs. They are also emitted from building materials, varnishes, paints, solvents, etc. [1]. Within the VOCs, BTEX (benzene, toluene, ethylbenzene, xylenes) are of greatest concern due to their health effects. Benzene, for example, is highly carcinogenic and the World Health Organization reports no safe level of exposure [2]. Gas chromatographs (GC) monitor air quality and can detect VOCs, these equipment are heavy, lab-based and non-portable. In 2016, Nasreddine [3] reported a miniaturized gas analyzer that can detect BTEX at ppb levels and weights 4 kg. In order to further reduce the size of this equipment and the consumption of carrier gas, its main components must be miniaturized and operate under low gas flow rate. The detector is one of the main components of the gas chromatograph, responsible for quantifying the chemicals sampled. This paper is centered on the type of detector named photo ionization detector (PID). The objective of this work is to present the main factors that affect the analytical PID performance. The information summarized here should be used as guidelines to design a future micro PID.Fig. 1 shows the basic elements of a photo ionization detector. In this device, a gas sample containing the chemicals flows through the ionization chamber, where photons emitted by the ionization source (UV lamp and window) reach the sample molecules. As a general rule, if the ionization energy of the photon is greater than the ionization potential of the molecule, ionization occurs. The electrodes establish then an electric field in the ionization chamber where the ionized molecules generate an ionization current proportional to the concentration of molecules in the gas sample.The performance of the PID is affected by design choices at the ionization source, ionization chamberand electrodes. The ionization source is selected according to the desired photon energy output,considering the target compounds to be detected. In theory, an ionization source with energy greater orequal to 9.3 ionizes all the BTEX molecules. However, Driscoll and Duffy [4] suggests to use the 10.2eV ionization source since it has the highest photon flux resulting in high PID sensitivity. The ionizationchamber should ensure uniform flow, otherwise the sensitivity of the PID is reduced [5]. Besides that,the ionization chamber volume should be as low as possible to reduce response time, thereby increasingsensitivity. A small volume also avoids remixing of organic species that have been previously separatedin the gas chromatograph and ensures uniform ionization of the sample, contributing positively to thelinearity and sensitivity of the signal. The electrodes inside the ionization chamber directly influencethe ion collection efficiency, which affects the sensitivity of the PID. Important electrode design aspectsinfluencing the ions collection efficiency are the electric field in the ionization chamber, the area of theelectrodes and the position of the electrodes in the ionization chamber [5].Micro and nanofabrication techniques can be used to miniaturize the PID with the possibility to improveits performance [5,6]. In the future, a micro PID design will be proposed and the most suitable microand nanofabrication technique for its fabrication will be evaluated. The new design will be based on themajor guidelines presented in this work with focus in diminishing both the ionization chamber volumeand the associated gas flow rate while maintaining low detection limit. The prototype will be evaluatedand compared to commercial PIDs
Utilizando text mining na taxonomia processual
Trabalho de Conclusão de Curso (graduação)—Universidade de Brasília, Faculdade UnB Gama, 2018.O trabalho apresenta uma avaliação de métodos supervisionados de classificação utilizando
como entrada processos judiciais. O sistema judicial brasileiro recebe milhões de
processos por ano, que possuem uma variedade de informações que interessam diversos
atores inclusive o poder executivo. A tarefa de classificar esses processos para análise
em pesquisas específicas é uma tarefa hercúlea sendo uma grande oportunidade para o
uso de algoritmos inteligentes. O trabalho utilizou os algoritmos knn e naive bayses para
classificar os processos judiciais e avaliou a performance dos dois algoritmos. O trabalho
resultou em valores adequados para os dois algoritmos podendo os dois serem usados para
a classificação de processos judiciais.The paper presents an evaluation of supervised learning methods of classification using
as input lawsuits. The Brazilian judicial system receives millions of cases per year, which
have a variety of information that interests research papaer and stakeholders including the
executive power. The task of classifying these processes for analysis in specific searches
is a Herculean task being a great opportunity for the use of intelligent algorithms. The
work utilized the knn and naive bayses algorithms to classify the judicial processes and
evaluated the performance of the two algorithms. The work resulted in adequate values
for the two algorithms, both of which can be used to classify lawsuits
Abordagem da saúde dos cuidadores
Trata-se de uma abordagem sobre atenção aos cuidadores familiares na Estratégia de Saúde da Família (ESF), levando em consideração suas ações com os seus doentes e com sua própria saúde. Em função do envelhecimento populacional crescente, vem aumentando a demanda dessas pessoas no dia a dia, que muitas das vezes é um familiar. Porém a saúde deles não pode ser esquecida. Discutiremos a abordagem de uma família acompanhada pela UBS Chacrinha, onde um membro da mesma cuidava de outro com sequelas de AVE. A partir desse cenário, realizamos reuniões de equipe, levamos em consideração a Planilha de Intervenção (PI) realizada durante o curso com supervisão médica do PROVAB, para que alcançássemos uma melhor qualidade vida do cuidador e da família em si, destacando a sua importância e disseminando a saúde e minimizando as intercorrências diárias
O PENSAMENTO AGONÍSTICO POR UMA DEMOCRACIA PLURAL: uma análise da teoria de Chantal Mouff
Este trabalho pretende analisar a obra da pensadora política belga Chantal Mouffe, através da evolução de seu conceito de uma democracia radical e plural. Baseado na leitura de seus principais textos, escritos em diferentes momentos, pretendemos traçar uma linha de união e evolução ao longo de sua teoria, para que possamos compreender melhor a trajetória desta autora que é um marco no pensamento político contemporâneo. Partindo de um modelo “agonista”, a autora pretende traçar as bases para uma democracia que seja “radical e plural”, onde tanto os conceitos de igualdade e de liberdade sejam respeitados. Apoiada na ideia de que o “político” é indissociável de uma dimensão conflitual, esta que não pode ser eliminada por nenhum processo racional de negociação, a autora faz sua crítica ao modelo deliberativo de Habermas ao mesmo tempo em que crítica o véu da ignorância trazido por Rawls. Ao trazer os argumentos que Mouffe coloca na introdução de seus textos pretendemos compreender como esta teoria foi desenvolvida ao longo da trajetória desta autora
- …