38 research outputs found

    Energy Response and Longitudinal Shower Profiles Measured in CMS HCAL and Comparison With Geant4

    Get PDF
    The response of the CMS combined electromagnetic and hadron calorimeter to beams of pions with momenta in the range 5-300 GeV/c has been measured in the H2 test beam at CERN. The raw response with the electromagnetic compartment calibrated to electrons and the hadron compartment calibrated to 300 GeV pions may be represented by sigma = (1.2) sqrt{E} oplus (0.095) E. The fraction of energy visible in the calorimeter ranges from 0.72 at 5 GeV to 0.95 at 300 GeV, indicating a substantial nonlinearity. The intrinsic electron to hadron ratios are fit as a function of energy and found to be in the range 1.3-2.7 for the electromagnetic compartment and 1.4-1.8 for the hadronic compartment. The fits are used to correct the non-linearity of the e pi response to 5% over the entire measured range resulting in a substantially improved resolution at low energy. Longitudinal shower profile have been measured in detail and compared to Geant4 models, LHEP-3.7 and QGSP-2.8. At energies below 30 GeV, the data, LHEP and QGSP are in agreement. Above 30 GeV, LHEP gives a more accurate simulation of the longitudinal shower profile

    Synchronization and Timing in CMS HCAL

    Get PDF
    The synchronization and timing of the hadron calorimeter (HCAL) for the Compact Muon Solenoid has been extensively studied with test beams at CERN during the period 2003-4, including runs with 40 MHz structured beam. The relative phases of the signals from different calorimeter segments are timed to 1 ns accuracy using a laser and equalized using programmable delay settings in the front-end electronics. The beam was used to verify the timing and to map out the entire range of pulse shapes over the 25 ns interval between beam crossings. These data were used to make detailed measurements of energy-dependent time slewing effects and to tune the electronics for optimal performance

    Design, Performance and Calibration of the CMS Forward Calorimeter Wedges

    Get PDF
    We report on the test beam results and calibration methods using charged particles of the CMS Forward Calorimeter (HF). The HF calorimeter covers a large pseudorapidity region (3\l |\eta| \le 5), and is essential for large number of physics channels with missing transverse energy. It is also expected to play a prominent role in the measurement of forward tagging jets in weak boson fusion channels. The HF calorimeter is based on steel absorber with embedded fused-silica-core optical fibers where Cherenkov radiation forms the basis of signal generation. Thus, the detector is essentially sensitive only to the electromagnetic shower core and is highly non-compensating (e/h \approx 5). This feature is also manifest in narrow and relatively short showers compared to similar calorimeters based on ionization. The choice of fused-silica optical fibers as active material is dictated by its exceptional radiation hardness. The electromagnetic energy resolution is dominated by photoelectron statistics and can be expressed in the customary form as a/\sqrt{E} + b. The stochastic term a is 198% and the constant term b is 9%. The hadronic energy resolution is largely determined by the fluctuations in the neutral pion production in showers, and when it is expressed as in the electromagnetic case, a = 280% and b = 11%

    The first Turkish family with Rotor syndrome diagnosed at the molecular level

    No full text
    Rotor syndrome is defined as a self-limiting hyperbilirubinemia characterized by jaundice that does not need treatment, cause any morbidity or affect life expectancy. As far as the literature is evaluated, the number of patients with Rotor syndrome diagnosed at the molecular level is less than 20 until today. In this case presentation, we aimed to present two siblings with Rotor syndrome who were diagnosed at the molecular level. To the nest of our knowledge, these patients are the first Turkish patients with Rotor syndrome diagnosed at the molecular level

    Zinc-coated Foam With Negative Pressure Wound Therapy in the Treatment of Challenging Wounds: A New Alternative Interface Material

    No full text
    Objective. The aim of the study was to present the authors' clinical observations on zinc-coated foam with negative pressure wound therapy (NPWT). MaterialS and Methods. Ninety-four consecutive patients treated with zinc-coated foam with VAC therapy were retrospectively reviewed. Nonhealing wounds of at least 6 months duration with high to moderate exudate that required open wound management to secondary intervention were included in this study. The evaluation criteria consisted of the measurement of wound surface area, length Of overall treatment time, and a clinical observation of granulation tissue formation in the wound bed. Results. In all wounds, there was a significant decrease of the wound surface area, and wound exudate was obtained at the end Of the treatment. There was a statistically significant difference between pretreatment and posttreatment measurements (P < 0.05). In all wounds, granulation tissue formation was clinically observed by day 6. Of the 94 wounds, 72 were surgically closed and 22 healed secondarily. The follow-up period averaged 12 months, and it was uneventful with no sign of complications from the use of the material. Conclusion. The results of the retrospective study demonstrate zinc-coatedfoam with NPWT can be safely used as an effective and alternative interface material in the treatment of challenging wounds

    Vinorelbine in Combination with Carboplatin followed by Single-agent Consolidation Therapy for Unresectable Localized or Metastatic Non-small-cell Lung Carcinomas

    No full text
    Background: Adding more than four cycles of the combination regimen increase toxicities. The availability of an intravenous (i.v.) and oral form of vinorelbine appeared as a particularly convenient way to provide a consolidation treatment to patients who have achieved an objective response or stable disease. Patients and methods: This study was retrospectively designed to investigate the efficacy in terms of response and safety of i.v. vinorelbine 25 mg/m(2) on day 1 and oral vinorelbine 60 mg/m(2) on day 8 given with carboplatin area under the curve (AUC) 5 once every 3 weeks (q3w) for four cycles followed by consolidation therapy with single-agent vinorelbine in non-progressive patients with advanced non-small-cell lung cancer (NSCLC). Results: Seventy-two patients enrolled into the study from October 2006 to July 2009 received the combination regimen. Thirty-seven patients (51.3%) also received the subsequent consolidation treatment. Partial tumor responses were obtained in 25 patients (34.7%) of 72 evaluable patients. Stable disease was observed in 26 (36.1%) of patients. The median progression free-survival was 4 months (95% CI 3.1-4.8). The median overall survival time was 10 months (95% CI 8.2-11.7) and the 1 year survival was 38.1%. The main toxicities recorded were hematological. Grade 3-4 neutropenia were observed in 17 patients (23.6%). Only two patients experienced grade three febrile neutropenia in the induction period, and there was no occurrence of febril neutropenia in the consolidation period. Nausea and vomiting were the major non-hematological toxicities reported. Toxicities occurred primarily during the initial combination phase of the chemotherapy. Conclusions: Despite the low dose of vinorelbine (25mg/m(2) i.v. on day 1 and only 60 mg/m(2) oral on day 8, every 3 weeks) achieved during the study, the response rate of 34.7%, the disease control of 70.8% and the 10 months median overall survival with tolerable toxicity profile, confirmed that this combination, offers an active and safe regimen for patients with advanced NSCL

    The prognostic value of detecting symptomatic or asymptomatic recurrence in patients with gastric cancer after a curative gastrectomy

    No full text
    Background: Although studies have investigated whether a routine follow-up should be performed after a gastrectomy, no consensus has been reached on the significance of the follow-up or the optimal surveillance protocol. In the present study, we evaluated the significance of the presence or absence of symptoms in the detection of recurrences after curative gastrectomy for gastric cancer
    corecore