608 research outputs found
Study of a high spatial resolution 10B-based thermal neutron detector for application in neutron reflectometry: the Multi-Blade prototype
Although for large area detectors it is crucial to find an alternative to
detect thermal neutrons because of the 3He shortage, this is not the case for
small area detectors. Neutron scattering science is still growing its
instruments' power and the neutron flux a detector must tolerate is increasing.
For small area detectors the main effort is to expand the detectors'
performances. At Institut Laue-Langevin (ILL) we developed the Multi-Blade
detector which wants to increase the spatial resolution of 3He-based detectors
for high flux applications. We developed a high spatial resolution prototype
suitable for neutron reflectometry instruments. It exploits solid 10B-films
employed in a proportional gas chamber. Two prototypes have been constructed at
ILL and the results obtained on our monochromatic test beam line are presented
here
Some Restrictions Abroad Affecting Corporations
A neutron detector concept based on solid layers of boron carbide enriched in 1 B has been in development for the last few years as an alternative for He-3 by collaboration between the ILL, ESS and Linkoping University. This Multi-Grid detector uses layers of aluminum substrates coated with (B4C)-B-10 on both sides that are traversed by the incoming neutrons. Detection is achieved using a gas counter readout principle. By segmenting the substrate and using multiple anode wires, the detector is made inherently position sensitive. This development is aimed primarily at neutron scattering instruments with large detector areas, such as time-of-flight chopper spectrometers. The most recent prototype has been built to be interchangeable with the He-3 detectors of IN6 at ILL. The 1 B detector has an active area of 32 x 48 cm(2). It was installed at the IN6 instrument and operated for several weeks, collecting data in parallel with the regularly scheduled experiments, thus providing the first side-by-side comparison with the conventional He-3 detectors. Results include an efficiency comparison, assessment of the in-detector scattering contribution, sensitivity to gamma-rays and the signal-to-noise ratio in time-of-flight spectra. The good expected performance has been confirmed with the exception of an unexpected background count rate. This has been identified as natural alpha activity in aluminum. New convertor substrates are under study to eliminate this source of background
A comparison of transgenic rodent mutation and in vivo comet assay responses for 91 chemicals.
A database of 91 chemicals with published data from both transgenic rodent mutation (TGR) and rodent comet assays has been compiled. The objective was to compare the sensitivity of the two assays for detecting genotoxicity. Critical aspects of study design and results were tabulated for each dataset. There were fewer datasets from rats than mice, particularly for the TGR assay, and therefore, results from both species were combined for further analysis. TGR and comet responses were compared in liver and bone marrow (the most commonly studied tissues), and in stomach and colon evaluated either separately or in combination with other GI tract segments. Overall positive, negative, or equivocal test results were assessed for each chemical across the tissues examined in the TGR and comet assays using two approaches: 1) overall calls based on weight of evidence (WoE) and expert judgement, and 2) curation of the data based on a priori acceptability criteria prior to deriving final tissue specific calls. Since the database contains a high prevalence of positive results, overall agreement between the assays was determined using statistics adjusted for prevalence (using AC1 and PABAK). These coefficients showed fair or moderate to good agreement for liver and the GI tract (predominantly stomach and colon data) using WoE, reduced agreement for stomach and colon evaluated separately using data curation, and poor or no agreement for bone marrow using both the WoE and data curation approaches. Confidence in these results is higher for liver than for the other tissues, for which there were less data. Our analysis finds that comet and TGR generally identify the same compounds (mainly potent mutagens) as genotoxic in liver, stomach and colon, but not in bone marrow. However, the current database content precluded drawing assay concordance conclusions for weak mutagens and non-DNA reactive chemicals
Frailty and inflammatory markers in older adults with cancer
We examined the associations between frailty and inflammatory markers, in particular neutrophil lymphocyte ratio (NLR), in elderly cancer patients. We conducted cross-sectional analyses of data derived from the Carolina Seniors Registry (CSR), a database of geriatric assessments (GA) in older adults (≧65 years) with cancer. We included patients in the CSR who had a GA and complete blood count test before initiation of therapy. The primary outcome was frailty, determined using the 36-item Carolina Frailty Index (CFI). In our sample of 133 patients, the median age was 74, and 54% were robust, 22% were pre-frail, and 24% were frail. There was a significant positive correlation between CFI and NLR (r = 0.22, p = 0.025). In multivariable analysis, patients in the top tertile of NLR had an odds ratio of 3.8 (95% CI = 1.1-12.8) for frail/pre-frail status, adjusting for age, sex, race, education level, marital status, cancer type and stage. In bivariable analyses, higher NLR was associated with lower instrumental activity of daily living (IADL) score (p = 0.040) and prolonged timed up and go (p = 0.016). This study suggests an association between frailty and inflammation in older adults with cancer
Experimental Search for Solar Axions
A new technique has been used to search for solar axions using a single crystal germanium detector. It exploits the coherent conversion of axions into photons when their angle of incidence satisfies a Bragg condition with a crystalline plane. The analysis of approximately 1.94 kg.yr of data from the 1-kg DEMOS detector in Sierra Grande, Argentina, yields a new laboratory bound on axion-photon coupling of g_{a,\gamma\gamma}<2.7\times 10^{-9} GeV^{-1} independent of axion mass up to \sim 1 keV
Determination of absolute neutrino masses from Z-bursts
Ultrahigh energy neutrinos (UHE\nu) scatter on relic neutrinos (R\nu)
producing Z bosons, which can decay hadronically producing protons (Z-burst).
We compare the predicted proton spectrum with the observed ultrahigh energy
cosmic ray (UHECR) spectrum and determine the mass of the heaviest R\nu via a
maximum likelihood analysis. Our prediction depends on the origin of the
power-like part of the UHECR spectrum: m_\nu=2.75^{+1.28}_{-0.97} eV for
Galactic halo and 0.26^{+0.20}_{-0.14} eV for extragalactic (EG) origin. The
necessary UHE\nu flux should be detected in the near future.Comment: slight rewording, revised neutrino fluxes, conclusions unchanged,
version to appear in Phys. Rev. Let
Relic neutrino masses and the highest energy cosmic rays
We consider the possibility that a large fraction of the ultrahigh energy
cosmic rays are decay products of Z bosons which were produced in the
scattering of ultrahigh energy cosmic neutrinos on cosmological relic
neutrinos. We compare the observed ultrahigh energy cosmic ray spectrum with
the one predicted in the above Z-burst scenario and determine the required mass
of the heaviest relic neutrino as well as the necessary ultrahigh energy cosmic
neutrino flux via a maximum likelihood analysis. We show that the value of the
neutrino mass obtained in this way is fairly robust against variations in
presently unknown quantities, like the amount of neutrino clustering, the
universal radio background, and the extragalactic magnetic field, within their
anticipated uncertainties. Much stronger systematics arises from different
possible assumptions about the diffuse background of ordinary cosmic rays from
unresolved astrophysical sources. In the most plausible case that these
ordinary cosmic rays are protons of extragalactic origin, one is lead to a
required neutrino mass in the range 0.08 eV - 1.3 eV at the 68 % confidence
level. This range narrows down considerably if a particular universal radio
background is assumed, e.g. to 0.08 eV - 0.40 eV for a large one. The required
flux of ultrahigh energy cosmic neutrinos near the resonant energy should be
detected in the near future by AMANDA, RICE, and the Pierre Auger Observatory,
otherwise the Z-burst scenario will be ruled out.Comment: 19 pages, 22 figures, REVTeX
Grand Unification Signal from Ultra High Energy Cosmic Rays?
The spectrum of ultrahigh energy (above \approx 10^{9} GeV) cosmic rays is
consistent with the decay of GUT scale particles. The predicted mass is
m_X=10^b GeV, where b=14.6_{-1.7}^{+1.6}.Comment: 4 pages, 3 figures one figure removed, one table added, conclusions
essentially remained the same within errorbar
- …