5 research outputs found

    A Follow-Up of the Multicenter Collaborative Study on HIV-1 Drug Resistance and Tropism Testing Using 454 Ultra Deep Pyrosequencing

    Get PDF
    Background: Ultra deep sequencing is of increasing use not only in research but also in diagnostics. For implementation of ultra deep sequencing assays in clinical laboratories for routine diagnostics, intra- and inter-laboratory testing are of the utmost importance. Methods: A multicenter study was conducted to validate an updated assay design for 454 Life Sciences’ GS FLX Titanium system targeting protease/reverse transcriptase (RTP) and env (V3) regions to identify HIV-1 drug-resistance mutations and determine co-receptor use with high sensitivity. The study included 30 HIV-1 subtype B and 6 subtype non-B samples with viral titers (VT) of 3,940–447,400 copies/mL, two dilution series (52,129–1,340 and 25,130–734 copies/mL), and triplicate samples. Amplicons spanning PR codons 10–99, RT codons 1–251 and the entire V3 region were generated using barcoded primers. Analysis was performed using the GS Amplicon Variant Analyzer and geno2pheno for tropism. For comparison, population sequencing was performed using the ViroSeq HIV-1 genotyping system. Results: The median sequencing depth across the 11 sites was 1,829 reads per position for RTP (IQR 592–3,488) and 2,410 for V3 (IQR 786–3,695). 10 preselected drug resistant variants were measured across sites and showed high inter-laboratory correlation across all sites with data (P20% were missed, variants 2–10% were detected at most sites (even at low VT), and variants 1–2% were detected by some sites. All mutations detected by population sequencing were also detected by UDS. Conclusions: This assay design results in an accurate and reproducible approach to analyze HIV-1 mutant spectra, even at variant frequencies well below those routinely detectable by population sequencing

    An international multicenter study on HIV-1 drug resistance testing by 454 ultra-deep pyrosequencing

    Full text link
    The detection of mutant spectra within the viral quasispecies is critical for therapeutic management of HIV-1 infections. Routine clinical application of ultrasensitive genotyping requires reproducibility and concordance within and between laboratories. The goal of the study was to evaluate a new protocol on HIV-1 drug resistance testing by 454 ultra-deep pyrosequencing (454-UDS) in an international multicenter study. Sixteen blinded HIV-1 subtype B samples were provided for 454-UDS as both RNA and cDNA with viral titers of 88,600-573,000 HIV-1 RNA copies/ml. Eight overlapping amplicons spanning protease (PR) codons 10-99 and reverse transcriptase (RT) codons 1-251 were generated using molecular barcoded primers. 454-UDS was performed using the 454 Life Sciences/Roche GS FLX platform. PR and RT sequences were analyzed using 454 Life Sciences Amplicon Variant Analyzer (AVA) software. Quantified variation data were analyzed for intra-laboratory reproducibility and inter-laboratory concordance. Routine population sequencing was performed using the ViroSeq HIV-1 genotyping system. Eleven laboratories and the reference laboratory 454 Life Sciences sequenced the HIV-1 sample set. Data presented are derived from seven laboratories and the reference laboratory since severe study protocol execution errors occurred in four laboratories leading to exclusion. The median sequencing depth across all sites was 1364 reads per position (IQR=809-2065). 100% of the ViroSeq-reported mutations were also detected by 454-UDS. Minority HIV-1 drug resistance mutations, defined as HIV-1 drug resistance mutations identified at frequencies of 1-25%, were only detected by 454-UDS. Analysis of 10 preselected majority and minority mutations were consistently found across sites. The analysis of drug-resistance mutations detected between 1 and 10% demonstrated high intra- and inter-laboratory consistency in frequency estimates for both RNA and prepared cDNA samples, indicating robustness of the method. HIV-1 drug resistance testing using 454 ultra-deep pyrosequencing results in an accurate and highly reproducible, albeit complex, approach to the analysis of HIV-1 mutant spectra, even at frequencies well below those detected by routine population sequencing

    A Follow-Up of the Multicenter Collaborative Study on HIV-1 Drug Resistance and Tropism Testing Using 454 Ultra Deep Pyrosequencing

    No full text
    Ultra deep sequencing is of increasing use not only in research but also in diagnostics. For implementation of ultra deep sequencing assays in clinical laboratories for routine diagnostics, intra- and inter-laboratory testing are of the utmost importance. 5A multicenter study was conducted to validate an updated assay design for 454 Life Sciences' GS FLX Titanium system targeting protease/reverse transcriptase (RTP) and env (V3) regions to identify HIV-1 drug-resistance mutations and determine co-receptor use with high sensitivity. The study included 30 HIV-1 subtype B and 6 subtype non-B samples with viral titers (VT) of 3,940-447,400 copies/mL, two dilution series (52,129-1,340 and 25,130-734 copies/mL), and triplicate samples. Amplicons spanning PR codons 10-99, RT codons 1-251 and the entire V3 region were generated using barcoded primers. Analysis was performed using the GS Amplicon Variant Analyzer and geno2pheno for tropism. For comparison, population sequencing was performed using the ViroSeq HIV-1 genotyping system. The median sequencing depth across the 11 sites was 1,829 reads per position for RTP (IQR 592-3,488) and 2,410 for V3 (IQR 786-3,695). 10 preselected drug resistant variants were measured across sites and showed high inter-laboratory correlation across all sites with data (P20% were missed, variants 2-10% were detected at most sites (even at low VT), and variants 1-2% were detected by some sites. All mutations detected by population sequencing were also detected by UDS. This assay design results in an accurate and reproducible approach to analyze HIV-1 mutant spectra, even at variant frequencies well below those routinely detectable by population sequencing

    Drug resistance mutation detection in limiting dilution series.

    No full text
    <p>Two HIV-1 subtype B samples were used for the dilution series (A, samples 40–44; B, samples 45–49). The four groups shown in the histogram are based on the median frequency of each drug resistance mutation in its respective <i>undiluted</i> sample: >20% (white bars), 10–20% (bright grey bars), 2–10% (dark grey bars), and 1–2% (black bars). The means and standard deviations are given of the percentage of sites reporting drug-resistance mutations in these categories. The number of mutations in each category is represented by n.</p
    corecore