91 research outputs found

    Analysis of reinforced concrete structures with occurrence of discrete cracks at arbitrary positions

    Get PDF
    A nonlinear analysis of in-plane loaded plates is presented, which eliminates the disadvantages of the smeared crack approach. The elements used and the computational method are discussed. An example is shown in which one or more discrete cracks are dominant

    Adaptive bone-remodeling theory applied to prosthetic-design analysis

    Get PDF
    The subject of this article is the development and application of computer-simulation methods to predict stress-related adaptive bone remodeling, in accordance with ‘Wolff's Law’. These models are based on the Finite Element Method (FEM) in combination with numerical formulations of adaptive bone-remodeling theories.\ud \ud In the adaptive remodeling models presented, the Strain Energy Density (SED) is used as a feed-back control variable to determine shape or bone density adaptations to alternative functional requirements, whereby homeostatic SED distribution is assumed as the remodeling objective.\ud \ud These models are applied to investigate the relation between ‘stress shielding’ and bone resorption in the femoral cortex around intramedullary prostheses, such as used in Total Hip Arthroplasty (THA). It is shown that the amount of bone resorption depends mainly on the rigidity and the bonding characteristics of the implant. Homeostatic SED can be obtained when the resorption process occurs at the periosteal surface, rather than inside the cortex, provided that the stem is adequately flexible

    The modelling and mechanical consequences of fibrous-tissue formation around femoral hip prostheses

    Get PDF
    On the longer term, bone resorption around the prosthesis may occur, at least when acrylic cement is used for fixation, resulting in a soft fibrous tissue layer between cement and bone. The mechanical behavior of a fibrous-tissue interface connection will therefore be governed by the following effects: 1) reduced compliance; 2) material nonlinearity of the tissue itself; 3) loosening on tension; 4) slip in shear; 5) time dependency. In the present analysis, a (nonlinear) 2-D finite element method model (using quasi 3-D structural characteristics) of femoral hip replacement was used to study the consequences of the effects 1 through 4 on the load-transfer mechanism, the stress patterns and the relative motions occurring between implant and bone. [9 Refs; In English

    An extendable modular endoprosthetic system for bone tumour management in the leg

    Get PDF
    A modular endoprosthetic system has been developed at the Groningen University Hospital and the University of Twente. The system can bridge a defect resulting from the resection of a malignant bone tumour which has developed around the knee joint of a child. Since the other healthy leg continues to grow, the system includes an element whose length can be adjusted non-invasively by using an external magnetic field. In addition to this lengthening element, there are one hip and two knee components, connectors of various lengths, and fixation elements. The paper describes the elements of the modular endoprosthetic system. Tables are created by means of which the elemental composition of such an endoprosthesis can be determined for each individual patient

    Design and analysis of coupling methods for modular endoprosthetic systems as an alternative to the conical coupling

    Get PDF
    Modular endoprostheses are often used in bone tumor management. However, the conical coupling that connects the various modules has several shortcomings. As an alternative, four new couplings have been developed. To find out if they have sufficient strength and show no movement during loading, each coupling was analysed using the finite element method. Bolt force and friction coefficient was varied to examine their influence. From the analysis it was concluded that coupling B, a dovetail coupling, meets all requirements and is the best alternative to the conical coupling. Sensitivity to bolt force and friction coefficient is very limited

    Trends of mechanical consequences and modeling of a fibrous membrane around femoral hip prostheses

    Get PDF
    In the present study, the effects of a fibrous membrane between cement and bone in a femoral total hip replacement were investigated. The study involved the problem of modeling this fibrous membrane in finite-element analyses, and its global consequences for the load-transfer mechanism and its resulting stress patterns. A finite-element model was developed, suitable to describe nonlinear contact conditions in combination with nonlinear material properties of the fibrous membrane. The fibrous tissue layer was described as a highly compliant material with little resistance against tension and shear. The analysis showed that the load transfer mechanism from stem to bone changes drastically when such a membrane is present. These effects are predominantly caused by tensile loosening and slip at the interface, and are enhanced by the nonlinear membrane characteristics.\ud \ud Using parametric analysis, it was shown that these effects on the load-transfer mechanism cannot be described satisfactorily with linear elastic models.\ud \ud Most importantly, the fibrous tissue interposition causes excessive stress concentrations in bone and cement, and relatively high relative displacements between these materials

    Quantitative analysis of bone reactions to relative motions at implant-bone interfaces

    Get PDF
    Connective soft tissues at the interface between implants and bone, such as in human joint replacements, can endanger the stability of the implant fixation. The potential of an implant to generate interface bone resorption and form soft tissue depends on many variables, including mechanical ones. These mechanical factors can be expressed in terms of relative motions between bone and implant at the interface or deformation of the interfacial material.\ud \ud The purpose of this investigation was to determine if interface debonding and subsequent relative interface motions can be responsible for interface degradation and soft tissue interposition as seen in experiments and clinical results. A finite element computer program was augmented with a mathematical description of interface debonding, dependent on interface stress criteria, and soft tissue interface interposition, dependent on relative interface motions. Three simplified models of orthopaedic implants were constructed: a cortical bone screw for fracture fixation plates, a femoral resurfacing prosthesis and a straight stem model, cemented in a bone. The predicted computer configurations were compared with clinical observations. The computer results showed how interface disruption and fibrous tissue interposition interrelate and possibly enhance each other, whereby a progressive development of the soft tissue layer can occur.\ud \ud Around the cortical bone screw, the predicted resorption patterns were relatively large directly under the screw head and showed a pivot point in the opposite cortex. The resurfacing cup model predicted some fibrous tissue formation under the medial and lateral cup rim, whereby the medial layer developed first because of higher initial interface stresses. The straight stem model predicted initial interface failure at the proximal parts. After proximal resorption and fibrous tissue interposition, the medial interface was completely disrupted and developed an interface layer. The distal and mid lateral side maintained within the strength criterion.\ud \ud Although the applied models were relatively simple, the results showed reasonable qualitative agreement with resorption patterns found in clinical studies concerning bone screws and the resurfacing cup. The hypothesis that interface debonding and subsequent relative (micro)motions could be responsible for bone resorption and fibrous tissue propagation is thereby sustained by the results

    Novel mutations in PIEZO1 cause an autosomal recessive generalized lymphatic dysplasia with non-immune hydrops fetalis.

    Get PDF
    Generalized lymphatic dysplasia (GLD) is a rare form of primary lymphoedema characterized by a uniform, widespread lymphoedema affecting all segments of the body, with systemic involvement such as intestinal and/or pulmonary lymphangiectasia, pleural effusions, chylothoraces and/or pericardial effusions. This may present prenatally as non-immune hydrops. Here we report homozygous and compound heterozygous mutations in PIEZO1, resulting in an autosomal recessive form of GLD with a high incidence of non-immune hydrops fetalis and childhood onset of facial and four limb lymphoedema. Mutations in PIEZO1, which encodes a mechanically activated ion channel, have been reported with autosomal dominant dehydrated hereditary stomatocytosis and non-immune hydrops of unknown aetiology. Besides its role in red blood cells, our findings indicate that PIEZO1 is also involved in the development of lymphatic structures

    Extramuscular myofascial force transmission alters substantially the acute effects of surgical aponeurotomy: assessment by finite element modeling

    Get PDF
    Effects of extramuscular myofascial force transmission on the acute effects of aponeurotomy were studied using finite element modeling and implications of such effects on surgery were discussed. Aponeurotomized EDL muscle of the rat was modeled in two conditions: (1) fully isolated (2) with intact extramuscular connections. The specific goal was to assess the alterations in muscle length-force characteristics in relation to sarcomere length distributions and to investigate how the mechanical mechanism of the intervention is affected if the muscle is not isolated. Major effects of extramuscular myofascial force transmission were shown on muscle length-force characteristics. In contrast to the identical proximal and distal forces of the aponeurotomized isolated muscle, substantial proximo-distal force differences were shown for aponeurotomized muscle with extramuscular connections (for all muscle lengths F dist > F prox after distal muscle lengthening). Proximal optimal length did not change whereas distal optimal length was lower (by 0.5 mm). The optimal forces of the aponeurotomized muscle with extramuscular connections exerted at both proximal and distal tendons were lower than that of isolated muscle (by 15 and 7%, respectively). The length of the gap separating the two cut ends of the intervened aponeurosis decreases substantially due to extramuscular myofascial force transmission. The amplitude of the difference in gap length was muscle length dependent (maximally 11.6% of the gap length of the extramuscularly connected muscle). Extramuscular myofascial force transmission has substantial effects on distributions of lengths of sarcomeres within the muscle fiber populations distal and proximal to the location of intervention: (a) Within the distal population, the substantial sarcomere shortening at the proximal ends of muscle fibers due to the intervention remained unaffected however, extramuscular myofascial force transmission caused a more pronounced serial distribution towards the distal ends of muscle fibers. (b) In contrast, extramuscular myofascial force transmission limits the serial distribution of sarcomere lengths shown for the aponeurotomized isolated muscle in the proximal population. Fiber stress distributions showed that extramuscular myofascial force transmission causes most sarcomeres within the aponeurotomized muscle to attain lengths favorable for higher force exertion. It is concluded that acute effects of aponeurotomy on muscular mechanics are affected greatly by extramuscular myofascial force transmission. Such effects have important implications for the outcome of surgery performed to improve impeded function since muscle in vivo is not isolated both anatomically and mechanically
    • …
    corecore