17 research outputs found

    Computed Tomography Imaging in Simulated Ongoing Cardiopulmonary Resuscitation: No Need to Switch Off the Chest Compression Device during Image Acquisition

    Get PDF
    Computed tomography (CT) represents the current standard for imaging of patients with acute life-threatening diseases. As some patients present with circulatory arrest, they require cardiopulmonary resuscitation. Automated chest compression devices are used to continue resuscitation during CT examinations, but tend to cause motion artifacts degrading diagnostic evaluation of the chest. The aim was to investigate and evaluate a CT protocol for motion-free imaging of thoracic structures during ongoing mechanical resuscitation. The standard CT trauma protocol and a CT protocol with ECG triggering using a simulated ECG were applied in an experimental setup to examine a compressible thorax phantom during resuscitation with two different compression devices. Twenty-eight phantom examinations were performed, 14 with AutoPulse and 14 with corpuls cpr. With each device, seven CT examinations were carried out with ECG triggering and seven without. Image quality improved significantly applying the ECG-triggered protocol (p < 0.001), which allowed almost artifact-free chest evaluation. With the investigated protocol, radiation exposure was 5.09% higher (15.51 mSv vs. 14.76 mSv), and average reconstruction time of CT scans increased from 45 to 76 s. Image acquisition using the proposed CT protocol prevents thoracic motion artifacts and facilitates diagnosis of acute life-threatening conditions during continuous automated chest compression

    Observation of gravitational waves from the coalescence of a 2.5−4.5 M⊙ compact object and a neutron star

    Get PDF

    Search for gravitational-lensing signatures in the full third observing run of the LIGO-Virgo network

    Get PDF
    Gravitational lensing by massive objects along the line of sight to the source causes distortions of gravitational wave-signals; such distortions may reveal information about fundamental physics, cosmology and astrophysics. In this work, we have extended the search for lensing signatures to all binary black hole events from the third observing run of the LIGO--Virgo network. We search for repeated signals from strong lensing by 1) performing targeted searches for subthreshold signals, 2) calculating the degree of overlap amongst the intrinsic parameters and sky location of pairs of signals, 3) comparing the similarities of the spectrograms amongst pairs of signals, and 4) performing dual-signal Bayesian analysis that takes into account selection effects and astrophysical knowledge. We also search for distortions to the gravitational waveform caused by 1) frequency-independent phase shifts in strongly lensed images, and 2) frequency-dependent modulation of the amplitude and phase due to point masses. None of these searches yields significant evidence for lensing. Finally, we use the non-detection of gravitational-wave lensing to constrain the lensing rate based on the latest merger-rate estimates and the fraction of dark matter composed of compact objects

    Search for eccentric black hole coalescences during the third observing run of LIGO and Virgo

    Get PDF
    Despite the growing number of confident binary black hole coalescences observed through gravitational waves so far, the astrophysical origin of these binaries remains uncertain. Orbital eccentricity is one of the clearest tracers of binary formation channels. Identifying binary eccentricity, however, remains challenging due to the limited availability of gravitational waveforms that include effects of eccentricity. Here, we present observational results for a waveform-independent search sensitive to eccentric black hole coalescences, covering the third observing run (O3) of the LIGO and Virgo detectors. We identified no new high-significance candidates beyond those that were already identified with searches focusing on quasi-circular binaries. We determine the sensitivity of our search to high-mass (total mass M&gt;70 M⊙) binaries covering eccentricities up to 0.3 at 15 Hz orbital frequency, and use this to compare model predictions to search results. Assuming all detections are indeed quasi-circular, for our fiducial population model, we place an upper limit for the merger rate density of high-mass binaries with eccentricities 0&lt;e≤0.3 at 0.33 Gpc−3 yr−1 at 90\% confidence level

    Ultralight vector dark matter search using data from the KAGRA O3GK run

    Get PDF
    Among the various candidates for dark matter (DM), ultralight vector DM can be probed by laser interferometric gravitational wave detectors through the measurement of oscillating length changes in the arm cavities. In this context, KAGRA has a unique feature due to differing compositions of its mirrors, enhancing the signal of vector DM in the length change in the auxiliary channels. Here we present the result of a search for U(1)B−L gauge boson DM using the KAGRA data from auxiliary length channels during the first joint observation run together with GEO600. By applying our search pipeline, which takes into account the stochastic nature of ultralight DM, upper bounds on the coupling strength between the U(1)B−L gauge boson and ordinary matter are obtained for a range of DM masses. While our constraints are less stringent than those derived from previous experiments, this study demonstrates the applicability of our method to the lower-mass vector DM search, which is made difficult in this measurement by the short observation time compared to the auto-correlation time scale of DM

    Changing the Patient&rsquo;s Position: Pitfalls and Benefits for Radiation Dose and Image Quality of Computed Tomography in Polytrauma

    No full text
    For computed tomography (CT), representing the diagnostic standard for trauma patients, image quality is essential. The positioning of the patient&rsquo;s arms next to the abdomen causes artifacts and is also considered to increase radiation exposure. The aim of this study was to evaluate the effect of various positionings during different CT examination steps on the extent of artifacts as well as radiation dose using iterative reconstruction (IR). 354 trauma-CTs were analyzed retrospectively. All datasets were reconstructed using IR and three different examination protocols were applied. Arm elevation led to a significant improvement of the image quality across all examination protocols (p &lt; 0.001). Variation in arm positioning during image acquisition did not lead to a reduction of radiation dose (p = 0.123). Only elevation during scout acquisition resulted in the reduction of radiation exposure (p &lt; 0.001). To receive high-quality CT images, patients should be placed with elevated arms for the trunk scan, as artifacts remain even with the IR. Arm repositioning during the examination itself had no effect on the applied radiation dose because its modulation refers to the initial scout obtained. In order to achieve a dose effect by different positioning, a two-scout protocol (dual scout) should be used

    Safety Analysis of Four Randomized Controlled Studies of Ibrutinib in Patients With Chronic Lymphocytic Leukemia/Small Lymphocytic Lymphoma or Mantle Cell Lymphoma

    Get PDF
    Ibrutinib, a Bruton's tyrosine kinase inhibitor, has become a standard treatment for patients with chronic lymphocytic leukemia/small lymphocytic lymphoma (CLL/SLL). The present pooled safety analysis of 4 randomized controlled studies demonstrated a favorable benefit/risk profile for ibrutinib in patients with CLL/SLL and mantle cell lymphoma. Multiple studies have demonstrated the efficacy and safety of ibrutinib for chronic lymphocytic leukemia/small lymphocytic lymphoma (CLL/SLL) and mantle cell lymphoma (MCL). This first-in-class inhibitor of Bruton's tyrosine kinase has become a standard treatment for patients with CLL and MCL. We conducted an integrated safety analysis to characterize the frequency, severity, natural history, and outcomes of adverse events (AEs) with ibrutinib versus comparators. Data were pooled from 4 completed randomized controlled studies that had included 756 ibrutinib-treated and 749 comparator-treated patients with CLL/SLL or relapsed/refractory MCL. Safety analyses included reporting of AEs using crude and exposure-adjusted incidence rates. The median treatment duration was 13.3 months (maximum, 28.2 months) for ibrutinib and 5.8 months (maximum, 27.3 months) for comparators. When adjusted for exposure, diarrhea, atrial fibrillation, and hypertension were the only common grade ≥ 3 AEs more often reported with ibrutinib than with the comparators. Dose reductions (7% vs. 14%) and discontinuation (12% vs. 16%) because of AEs occurred less often with ibrutinib, and deaths due to AEs occurred at similar rates (6% vs. 7%). When adjusted for exposure, the corresponding data were all lower with ibrutinib than with the comparators (0.06 vs. 0.22, 0.11 vs. 0.22, and 0.06 vs. 0.09 patient-exposure-years, respectively). The prevalence of common grade 3/4 AEs with ibrutinib generally decreased over time, with the exception of hypertension. These results from an integrated analysis support a favorable benefit/risk profile of ibrutinib in patients with CLL/SLL and MCL

    Safety Analysis of Four Randomized Controlled Studies of Ibrutinib in Patients With Chronic Lymphocytic Leukemia/Small Lymphocytic Lymphoma or Mantle Cell Lymphoma

    No full text
    Ibrutinib, a Bruton's tyrosine kinase inhibitor, has become a standard treatment for patients with chronic lymphocytic leukemia/small lymphocytic lymphoma (CLL/SLL). The present pooled safety analysis of 4 randomized controlled studies demonstrated a favorable benefit/risk profile for ibrutinib in patients with CLL/SLL and mantle cell lymphoma. Background: Multiple studies have demonstrated the efficacy and safety of ibrutinib for chronic lymphocytic leukemia/small lymphocytic lymphoma (CLL/SLL) and mantle cell lymphoma (MCL). This first-in-class inhibitor of Bruton's tyrosine kinase has become a standard treatment for patients with CLL and MCL. Patients and Methods: We conducted an integrated safety analysis to characterize the frequency, severity, natural history, and outcomes of adverse events (AEs) with ibrutinib versus comparators. Data were pooled from 4 completed randomized controlled studies that had included 756 ibrutinib-treated and 749 comparator-treated patients with CLL/SLL or relapsed/refractory MCL. Safety analyses included reporting of AEs using crude and exposure-adjusted incidence rates. Results: The median treatment duration was 13.3 months (maximum, 28.2 months) for ibrutinib and 5.8 months (maximum, 27.3 months) for comparators. When adjusted for exposure, diarrhea, atrial fibrillation, and hypertension were the only common grade >= 3 AEs more often reported with ibrutinib than with the comparators. Dose reductions (7% vs. 14%) and discontinuation (12% vs. 16%) because of AEs occurred less often with ibrutinib, and deaths due to AEs occurred at similar rates (6% vs. 7%). When adjusted for exposure, the corresponding data were all lower with ibrutinib than with the comparators (0.06 vs. 0.22, 0.11 vs. 0.22, and 0.06 vs. 0.09 patient-exposure-years, respectively). The prevalence of common grade 3/4 AEs with ibrutinib generally decreased over time, with the exception of hypertension. Conclusion: These results from an integrated analysis support a favorable benefit/risk profile of ibrutinib in patients with CLL/SLL and MCL. (C) 2018 The Authors. Published by Elsevier Inc

    Newborn hearing screening vs later hearing screening and developmental outcomes in children with permanent childhood hearing impairment.

    No full text
    Item does not contain fulltextCONTEXT: Newborn hearing screening programs have been implemented in many countries because it was thought that the earlier permanent childhood hearing impairment is detected, the less developmentally disadvantaged children would become. To date, however, no strong evidence exists for universal introduction of newborn hearing screening. OBJECTIVE: To study the effect of newborn hearing screening vs distraction hearing screening, conducted at 9 months of age, on development, spoken communication, and quality of life. DESIGN, SETTING, AND PARTICIPANTS: Between 2002 and 2006, all 65 regions in The Netherlands replaced distraction hearing screening with newborn hearing screening. Consequently, the type of hearing screening offered was based on availability at the place and date of birth and was independent of developmental prognoses of individual children. All children born in The Netherlands between 2003 and 2005 were included. At the age of 3 to 5 years, all children with permanent childhood hearing impairment were identified. Evaluation ended December 2009. MAIN OUTCOME MEASURES: Performance (education and spoken and signed communication), development (general and language), and quality of life. RESULTS: During the study period, 335,560 children were born in a newborn hearing screening region and 234,826 children in a distraction hearing screening region. At follow-up, 263 children in newborn hearing screening regions (0.78 per 1000 children) and 171 children in distraction hearing screening regions (0.73 per 1000 children) had been diagnosed with permanent childhood hearing impairment. Three hundred one children (69.4%) participated in analysis of general performance measures. There was no difference between groups in the primary mode of communication or type of education. Analysis of extensive developmental outcomes included 80 children born in newborn hearing screening regions and 70 in distraction hearing screening regions. Multivariate analysis of variance showed that overall, children in newborn hearing screening regions had higher developmental outcome scores compared with children in distraction hearing screening regions (Wilks lambda = 0.79; F(12) = 2.705; P = .003). For social development, the mean between-group difference in quotient points was 8.8 (95% CI, 0.8 to 16.7) and for gross motor development, 9.1 (95% CI, 1.1 to 17.1). For quality of life, the mean between-group difference was 5.3 (95% CI, 1.7 to 8.9), also in favor of children in newborn hearing screening regions. CONCLUSION: Compared with distraction hearing screening, a newborn hearing screening program was associated with better developmental outcomes at age 3 to 5 years among children with permanent childhood hearing impairment
    corecore