38 research outputs found

    Temporal characterization of individual harmonics of an attosecond pulse train by THz streaking

    Full text link
    We report on the global temporal pulse characteristics of individual harmonics in an attosecond pulse train by means of photo-electron streaking in a strong low-frequency transient. The scheme allows direct retrieval of pulse durations and first order chirp of individual harmonics without the need of temporal scanning. The measurements were performed using an intense THz field generated by tilted phase front technique in LiNbO_3 . Pulse properties for harmonics of order 23, 25 and 27 show that the individual pulse durations and linear chirp are decreasing by the harmonic order

    Commissioning of the electron injector for the AWAKE experiment

    Get PDF
    The advanced wakefield experiment (AWAKE) at CERN is the first proton beam-driven plasma wakefield acceleration experiment. The main goal of AWAKE RUN 1 was to demonstrate seeded self-modulation (SSM) of the proton beam and electron witness beam acceleration in the plasma wakefield. For the AWAKE experiment, a 10-meter-long Rubidium-vapor cell together with a high-power laser for ionization was used to generate the plasma. The plasma wakefield is driven by a 400 GeV/c proton beam extracted from the super proton synchrotron (SPS), which undergoes a seeded self-modulation process in the plasma. The electron witness beam used to probe the wakefields is generated from an S-band RF photo-cathode gun and then accelerated by a booster structure up to energies between 16 and 20 MeV. The first run of the AWAKE experiment revealed that the maximum energy gain after the plasma cell is 2 GeV, and the SSM mechanism of the proton beam was verified. In this paper, we will present the details of the AWAKE electron injector. A comparison of the measured electron beam parameters, such as beam size, energy, and normalized emittance, with the simulation results was performed

    The AWAKE Electron Spectrometer

    Get PDF
    The AWAKE experiment at CERN aims to use a proton driven plasma wakefield to accelerate electrons from 10–20 MeV up to GeV energies in a 10 m plasma cell. We present the design of the magnetic spectrometer which will measure the electron energy distribution. Results from the calibration of the spectrometer's scintillator and optical system are presented, along with a study of the backgrounds generated by the 400 GeV SPS proton beam

    Measurement and application of electron stripping of ultrarelativistic 208Pb81+^{208}\textrm{Pb}^{81+}

    Get PDF
    New measurements of the stripping cross-section for ultrarelativistic hydrogen-like lead ions passing through aluminium and silicon have been performed at the Advanced Wakefield experiment at CERN. Agreement with existing measurements and theory has been obtained. Improvements in terms of electron beam quality and ion beam diagnostic capability, as well as further applications of such an electron beam, are discussed

    Commissioning of Beam Instrumentation at the Cern Awake Facility After Integration of the Electron Beam Line

    Get PDF
    The Advanced Proton Driven Plasma Wakefield Acceleration Experiment (AWAKE) is a project at CERN aiming to accelerate an electron bunch in a plasma wakefield driven by a proton bunch. The plasma is induced in a 10 m long rubidium vapor cell using a pulsed Ti:Sapphire laser, with the wakefield formed by a proton bunch from the CERN Super Proton Synchrotron (SPS). A 16 MeV electron bunch is simultaneously injected into the plasma cell to be accelerated by the wakefield to energies in the GeV range over this short distance. After successful runs with the proton and laser beams, the electron beam line was installed and commissioned at the end of 2017 to produce and inject a suitable electron bunch into the plasma cell. To achieve the goals of the experiment, it is important to have reliable beam instrumentation measuring the various parameters of the proton, electron and laser beams. This contribution presents the status of the beam instrumentation in AWAKE and reports on the performance achieved during the AWAKE runs in 2017

    Experimental study of extended timescale dynamics of a plasma wakefield driven by a self-modulated proton bunch

    Get PDF
    Plasma wakefield dynamics over timescales up to 800 ps, approximately 100 plasma periods, are studied experimentally at the Advanced Wakefield Experiment (AWAKE). The development of the longitudinal wakefield amplitude driven by a self-modulated proton bunch is measured using the external injection of witness electrons that sample the fields. In simulation, resonant excitation of the wakefield causes plasma electron trajectory crossing, resulting in the development of a potential outside the plasma boundary as electrons are transversely ejected. Trends consistent with the presence of this potential are experimentally measured and their dependence on wakefield amplitude are studied via seed laser timing scans and electron injection delay scan

    Experimental Observation of Plasma Wakefield Growth Driven by the Seeded Self-Modulation of a Proton Bunch

    Get PDF
    We measure the effects of transverse wakefields driven by a relativistic proton bunch in plasma with densities of 2.1 x 10(14) and 7.7 x 10(14) electrons/cm(3). We show that these wakefields periodically defocus the proton bunch itself, consistently with the development of the seeded self-modulation process. We show that the defocusing increases both along the bunch and along the plasma by using time resolved and time-integrated measurements of the proton bunch transverse distribution. We evaluate the transverse wakefield amplitudes and show that they exceed their seed value (< 15 MV/m) and reach over 300 MV/m. All these results confirm the development of the seeded self-modulation process, a necessary condition for external injection of low energy and acceleration of electrons to multi-GeV energy levels

    Experimental Observation of Proton Bunch Modulation in a Plasma at Varying Plasma Densities

    Get PDF
    We give direct experimental evidence for the observation of the full transverse self-modulation of a long, relativistic proton bunch propagating through a dense plasma. The bunch exits the plasma with a periodic density modulation resulting from radial wakefield effects. We show that the modulation is seeded by a relativistic ionization front created using an intense laser pulse copropagating with the proton bunch. The modulation extends over the length of the proton bunch following the seed point. By varying the plasma density over one order of magnitude, we show that the modulation frequency scales with the expected dependence on the plasma density, i.e., it is equal to the plasma frequency, as expected from theory

    BioMAX the first macromolecular crystallography beamline at MAX IV Laboratory

    Get PDF
    BioMAX is the first macromolecular crystallography beamline at the MAX IV Laboratory 3 GeV storage ring, which is the first operational multi bend achromat storage ring. Due to the low emittance storage ring, BioMAX has a parallel, high intensity X ray beam, even when focused down to 20 mm 5 mm using the bendable focusing mirrors. The beam is tunable in the energy range 5 25 keV using the in vacuum undulator and the horizontally deflecting doublecrystal monochromator. BioMAX is equipped with an MD3 diffractometer, an ISARA high capacity sample changer and an EIGER 16M hybrid pixel detector. Data collection at BioMAX is controlled using the newly developed MXCuBE3 graphical user interface, and sample tracking is handled by ISPyB. The computing infrastructure includes data storage and processing both at MAX IV and the Lund University supercomputing center LUNARC. With state of the art instrumentation, a high degree of automation, a user friendly control system interface and remote operation, BioMAX provides an excellent facility for most macromolecular crystallography experiments. Serial crystallography using either a high viscosity extruder injector or the MD3 as a fixedtarget scanner is already implemented. The serial crystallography activities at MAX IV Laboratory will be further developed at the microfocus beamline MicroMAX, when it comes into operation in 2022. MicroMAX will have a 1 mm x 1 mm beam focus and a flux up to 10 15 photons s 1 with main applications in serial crystallography, room temperature structure determinations and time resolved experiment
    corecore