484 research outputs found
Conventional dual-cure versus self-adhesive resin cements in dentin bond integrity
During post preparation, the root canal is exposed to the oral cavity, and endodontic treatment may fail because of coronal leakage, bacterial infection and sealing inability of the luting cement. OBJECTIVE: this study quantified the interfacial continuity produced with conventional dual-cure and self-adhesive resin cements in the cervical (C), medium (M) and apical (A) thirds of the root. MATERIAL AND METHODS: Forty single-rooted human teeth were restored using Reforpost # 01 conical glass-fiber posts and different materials (N=10 per group): group AC=Adper™ ScotchBond™ Multi-purpose Plus + AllCem; group ARC=Adper™ ScotchBond™ Multi-purpose Plus + RelyX ARC; group U100=RelyX U100; and group MXC=Maxcem Elite. After being kept in 100% humidity at 37°C for 72 hours, the samples were sectioned parallel to their longitudinal axis and positive epoxy resin replicas were made. The scanning electron micrographs of each third section of the teeth were combined using Image Analyst software and measured with AutoCAD-2002. We obtained percentage values of the interfacial continuity. RESULTS: Interfacial continuity was similar in the apical, medium and cervical thirds of the roots within the groups (Friedman test, p>0.05). Comparison of the different cements in a same root third showed that interfacial continuity was lower in MXC (C=45.5%; M=48.5%; A=47.3%) than in AC (C=85.9%, M=81.8% and A=76.0%), ARC (C=83.8%, M=82.4% and A=75.0%) and U100 (C=84.1%, M=82.4% and A=77.3%) (Kruskal-Wallis test, p<0.05). CONCLUSIONS: Allcem, Rely X ARC and U100 provide the best cementation; cementation was similar among root portions; in practical terms, U100 is the best resin because it combines good cementation and easy application and none of the cements provides complete interfacial continuity
Influence of Modeling Liquids and Universal Adhesives Used as Lubricants on Color Stability and Translucency of Resin-Based Composites
The use of lubricants during restorative procedures is a clinically common practice to alleviate the stickiness of resin-based composite (RBCs) materials and to improve its handling. This study evaluated the effects of three modeling liquids (ML) and one universal adhesive (UA) used as lubricants during composite layering on the color stability and translucency of RBCs. Methods. The following materials were applied between every 1 mm RBC layer (total restoration height of 4 mm): GC modeling liquid (GCML, GC Corporation, Tokyo, Japan), composite wetting resin (UPWR, Ultradent Products, South Jordan, UT, USA), Bisco modeling resin (BSMR, Bisco Inc., Schaumburg, IL, USA) as an ML and Clearfil Universal Bond Quick (KUBQ, Kuraray Noritake Dental, Tokyo, Japan) as a UA. Lubricant-free specimens were used as the control. Color coordinates (L*, a* and b*) were recorded at baseline and after a simulation of 1 month of coffee consumption. Data were analyzed using ANOVA and a post hoc Tukey test (p < 0.05). Results. All lubricants induced a color change higher than the perceptibility threshold (ΔE00 > 0.81). GCML showed the highest color stability. The use of KUBQ resulted in significantly higher a* values (p = 0.001) at baseline and after staining. KUBQ and UPWR significantly influenced the color stability (ΔE00, p = 0.0001) after staining, overcoming the clinical acceptability threshold (ΔE00 > 1.77). Conclusions. The use of lubricants may affect color stability at baseline and after simulation of staining. Translucency was not affected at baseline nor after staining. Clinical Significance. Clinicians should be aware that some lubricants may affect color stability, even at baseline
In vivo and in vitro permeability of one-step self-etch adhesives
Adhesive dentistry should effectively restore the peripheral seal of dentin after enamel removal. We hypothesize that non-rinsing, simplified, one-step self-etch adhesives are effective for minimizing dentin permeability after tooth preparation procedures. Crown preparations in vital human teeth were sealed with Adper Prompt, Xeno III, iBond, or One-Up Bond F. Epoxy resin replicas were produced from polyvinyl siloxane impressions for SEM examination. Dentin surfaces from extracted human teeth were bonded with these adhesives and connected to a fluid-transport model for permeability measurements and TEM examination. Dentinal fluid droplets were observed from adhesive surfaces in resin replicas of in vivo specimens. In vitro fluid conductance of dentin bonded with one-step self-etch adhesives was either similar to or greater than that of smear-layer-covered dentin. TEM revealed water trees within the adhesives that facilitate water movement across the polymerized, highly permeable adhesives. Both in vitro and in vivo results did not support the proposed hypothesis.published_or_final_versio
Solvent and water retention in dental adhesive films after evaporation
published_or_final_versio
Solvent and water retention in dental adhesive blends after evaporation
This study examined the extent of organic solvent and water retention in comonomer blends with different hydrophilicity (Hoy's solubility parameter for hydrogen bonding, δh) after solvent evaporation, and the extent of tracer penetration in polymerised films prepared from these resins. For each comonomer blend, adhesive/solvent mixtures were prepared by addition of (1) 50 wt% acetone, (2) 50 wt% ethanol, (3) 30 wt% acetone and 20 wt% water and (4) 30 wt% ethanol and 20 wt% water. The mixtures were placed in glass wells and evaporated for 30-60 s for acetone-based resins, and 60-120 s for ethanol-based resins. The weight of the comonomer mixtures was measured before and after solvent evaporation. Resin films were prepared for transmission electron microscopy (TEM) after immersion in ammonical silver nitrate. The percentages of solvent and water retained in the comonomer mixtures, and between the acetone and ethanol groups were measured gravimetrically and were statistically compared. In comonomer-organic solvent mixtures, the percentage of solvent retained in acetone and ethanol-based mixtures increased significantly with hydrophilicity of the comonomer blends (P<0.05). In resin-organic solvent-water mixtures, significantly more solvent and water were retained in the ethanol-based mixtures (P<0.0001), when compared to acetone-based mixtures after 60 s of air-drying. TEM revealed residual water being trapped as droplets in resin films containing acetone and water. Water-filled channels were seen along the film periphery of all groups and throughout the entire resin films containing ethanol and water. The addition of water to comonomer-ethanol mixtures results in increased retention of both ethanol and water because both solvents can hydrogen bond to the monomers. © 2005 Elsevier Ltd. All rights reserved.postprin
Incompatibility profiles of all-in-one adhesives. II. Contribution of oxygen inhibition
published_or_final_versio
Influence of low-ph beverages on the two-body wear of cad/cam monolithic materials
The aim of this in vitro study is to evaluate the effect of different acidic media on volumetric wear and surface roughness of CAD/CAM monolithic materials. Forty-eight rectangular specimens were prepared using different CAD/CAM monolithic materials: nanohybrid composite (Grandio Blocks, Voco), resin-based composite (Cerasmart, GC), lithium disilicate (E-Max, Ivoclar), and high-translucency zirconia (Katana STML, Kuraray Noritake). After storage in distilled water at 37â—¦ C for two days, the specimens were tested using a chewing machine with a stainless-steel ball as an antagonist (49N loads, 250,000 cycles). Testing was performed using distilled water, Coca-Cola, and Red Bull as abrasive media. Wear and surface roughness analyses of the CAD/CAM materials were performed using a 3D profilometer and analyzed with two-way analysis of variance and post hoc pairwise comparison procedures. Worn surfaces were examined using scanning electron microscopy. Resin-based materials suffered higher volumetric wear than ceramics (p = 0.00001). Water induced significantly less volumetric wear than the other tested solutions (p = 0.0014), independent of the material tested. High-translucency zirconia showed less surface roughness than all the other materials tested. The selection of monolithic CAD/CAM materials to restore worn dentition due to erosive processes could impact restorative therapy stability over time. Resin-based materials seem to be more influenced by the acidic environment when subjected to a two-body wear test
Influence of different scanning techniques on in vitro performance of CAD-CAM-fabricated fiber posts
This study assessed push-out strength, cement layer thickness, and interfacial nanoleakage of luted fiber posts fabricated with computer-aided design/computer-assisted manufacture (CAD/CAM) technology after use of 1 of 3 scanning techniques, namely, direct scanning of the post space (DS), scanning of a polyether impression of the post space (IS), and scanning of a plaster model of the post space (MS). Thirty premolars were randomly assigned to three groups corresponding to the scanning technique. Posts were computer-designed and milled from experimental fiber-reinforced composite blocks. The mean (±SD) values for push-out strength and cement thickness were 17.1 ± 7.7 MPa and 162 ± 24 μm, respectively, for DS, 10.7 ± 4.6 MPa and 187 ± 50 μm for IS, and 12.0 ± 7.2 MPa and 258 ± 78 μm for MS specimens. Median (interquartile range) interfacial nanoleakage scores were 3 (2-4) for DS, 2.5 (2-4) for IS, and 3 (2-4) for MS. Post retention was better for fiber posts fabricated by DS technique than for those fabricated by IS and MS. Cement thickness did not differ between DS and IS specimens, but the cement layer was significantly thicker in the MS group than in the other two groups. Scanning technique did not affect sealing ability, as the three groups had comparable nanoleakage values
- …