110 research outputs found

    Developments in circular external fixators: a review

    Get PDF
    Circular external fixators (CEFs) are successfully used in orthopedics owing to their highly favorable stiffness characteristics which promote distraction osteogenesis. Although there are different designs of external fixators, how these features produce optimal biomechanics through structural and component designs is not well known. Therefore, the aim of this study was to conduct a review on CEFs following the PRISMA statement. A search for relevant research articles was performed on Scopus and PubMed databases providing the related keywords. Furthermore, a patent search was conducted on the Google Patent database. 126 records were found to be eligible for the review. Different designs of CEFs were summarized and tabulated based on their specific features. A bibliometric analysis was also performed on the eligible research papers. Based on the findings, the developments of CEFs in terms of materials, automation, adjustment methods, component designs, wire-clamping, and performance evaluation have been extensively discussed. The trends of the CEF design and future directions are also discussed in this review. Significant research gaps include a lack of consideration towards ease of assembly, effective wire-clamping methods, and CEFs embedded with online patient-monitoring systems, among others. An apparent lack of research interest from low-middle and low-income countries was also identified

    Novel soft bending actuator based power augmentation hand exoskeleton controlled by human intention

    Get PDF
    This article presents the development of a soft material power augmentation wearable robot using novel bending soft artificial muscles. This soft exoskeleton was developed as a human hand power augmentation system for healthy or partially hand disabled individuals. The proposed prototype serves healthy manual workers by decreasing the muscular effort needed for grasping objects. Furthermore, it is a power augmentation wearable robot for partially hand disabled or post-stroke patients, supporting and augmenting the fingers’ grasping force with minimum muscular effort in most everyday activities. This wearable robot can fit any adult hand size without the need for any mechanical system changes or calibration. Novel bending soft actuators are developed to actuate this power augmentation device. The performance of these actuators has been experimentally assessed. A geometrical kinematic analysis and mathematical output force model have been developed for the novel actuators. The performance of this mathematical model has been proven experimentally with promising results. The control system of this exoskeleton is created by hybridization between cascaded position and force closed loop intelligent controllers. The cascaded position controller is designed for the bending actuators to follow the fingers in their bending movements. The force controller is developed to control the grasping force augmentation. The operation of the control system with the exoskeleton has been experimentally validated. EMG signals were monitored during the experiments to determine that the proposed exoskeleton system decreased the muscular efforts of the wearer

    Upper limb rehabilitation using robotic exoskeleton systems: a systematic review

    Get PDF
    Exoskeleton assisted therapy has been reported as a significant reduction in impairment and gain in functional abilities of stroke patients. In this paper, we conduct a systematic review on the upper limb rehabilitation using robotic exoskeleton systems. This review is based on typical mechanical structures and control strategies for exoskeletons in clinical rehabilitation conditions. A variety of upper limb exoskeletons are classified and reviewed according to their rehabilitation joints. Special attentions are paid to the performance control strategies and mechanism designs in clinical trials and to promote the adaptability to different patients and conditions. Finally, we analyze and highlight the current research gaps and the future directions in this field. We intend to offer informative resources and reliable guidance for relevant researcher’s further studies, and exert a far-reaching influence on the development of advanced upper limb exoskeleton robotic systems

    A review : a comprehensive review of soft and rigid wearable rehabilitation and assistive devices with a focus on the shoulder joint

    Get PDF
    The importance of the human upper limb role in performing daily life and personal activities is significant. Improper functioning of this organ due to neurological disorders or surgeries can greatly affect the daily activities performed by patients. This paper aims to comprehensively review soft and rigid wearable robotic devices provided for rehabilitation and assistance focusing on the shoulder joint. In the last two decades, many devices have been proposed in this regard, however, there have been a few groups whose devices have had effective therapeutic capability with acceptable clinical evidence. Also, there were not many portable, lightweight and user-friendly devices. Therefore, this comprehensive study could pave the way for achieving optimal future devices, given the growing need for these devices. According to the results, the most commonly used plan was Exoskeleton, the most commonly used actuators were electrical, and most devices were considered to be stationary and rigid. By doing these studies, the advantages and disadvantages of each method are also presented. The presented devices each have a new idea and attitude in a specific field to solve the problems of movement disorders and rehabilitation, which were in the form of prototypes, initial clinical studies and sometimes comprehensive clinical and commercial studies. These plans need more comprehensive clinical trials to become a complete and efficient plan. This article could be used by researchers to identify and evaluate the important features and strengths and weaknesses of the plans to lead to the presentation of more optimal plans in the future

    Comparative study of actuation systems for portable upper limb exoskeletons.

    Get PDF
    During the last two decades, a large variety of upper limb exoskeletons have been developed. Out of these, majority are platform based systems which might be the reason for not being widely adopted for post-stroke rehabilitation. Despite the potential benefits of platform-based exoskeletons as being rugged and reliable, stroke patients prefer to have a portable and user-friendly device that they can take home. However, the types of actuator as well as the actuation mechanism used in the exoskeleton are the inhibiting factors why portable exoskeletons are mostly non-existent for patient use. This paper presents a quantitative analysis of the actuation systems available for developing portable upper arm exoskeletons with their specifications. Finally, it has been concluded from this research that there are not many stand-alone arm exoskeletons which can provide all forms of rehabilitation, therefore, a generic solution has been proposed as the rehabilitation strategy to get best out of the portable arm exoskeletons

    Analaysis and simulation of a poly bag manufacturing systems

    No full text
    The film blowing plays a major role in manufacturing poly bag products that are indispensable in day-to-day life. Film blowing is largely deployed to manufacture poly bags in a continuous flow. As material prices skyrocket to new heights and forecasters see no end to this trend, any positive contribution in the poly bag manufacturing value chain has a great impact on reducing the manufacturing costs. High density polyethylene (HDPE), low density polyethylene (LDPE), linear low density polyethylene (LLDPE), and polypropylene (PP) are basically used as raw materials for the poly bag manufacturing and subsequently undergo some other processes such as cutting, sealing, printing, quality checking, and packing. Due to the variations of parameters in poly bag manufacturing process with different products, a considerable setting time as conceded and substantial amount of raw material is wasted. Material wastage is high as 10% to 12% in figures. Rather high lead-time, improper line balancing, and improper inventory control mimic serious bottlenecks in the system from performance point of view. With the purpose of identifying the productivity and the efficiency problems of the poly bag manufacturing system, as a preliminary study to simulation, risk analysis, bottle neck analysis, and SWOT analysis were carried out in poly bag manufacturing system. Then the possible risk of the selected system was prioritized. In addition, a computer based simulation has been carried out to simulate the system and thereby find the draw backs. The poly bag manufacturing system has been modelled to obtain the optimum production times and throughput time of a given type of bag. Production schedule has been developed for maximum productivity by using the simulated production and throughput times, and customer orders. The effect of changing the parameters of the control process was investigated through simulation trials. A Graphical User Interface (GUI) was developed to present the result of simulation easily and user friendly

    Design of an ergonomically efficient chair

    No full text
    Ergonomically designed chairs are important for long time seated workers to increase their productivity and also to reduce low back injuries due to use of poorly designed chairs in ergonomic aspects. In addition, ergonomically designed chairs increase the seating comfortability of the chair users. Most of the chairs designed for the long time seated workers are not considered the full ergonomic aspects. In this paper, we discuss a design of an ergonomically efficient chair for the long time seated workers to increase their productivity and also to reduce low back injuries
    • …
    corecore