15 research outputs found

    ATOMS (Adjustable Transobturator Male System) Is an Effective and Safe Second-Line Treatment Option for Recurrent Urinary Incontinence after Implantation of an AdVance/AdVance XP Fixed Male Sling? A Multicenter Cohort Analysis

    Get PDF
    (1) Background: This study examined outcomes of second-line ATOMS implantation after failure of the fixed male sling (FMS) AdVance/AdVance XP. (2) Methods: A retrospective multicenter cohort analysis was carried out in men implanted with an ATOMS between 2011 and 2020 after failure of an AdVance/AdVance XP. Success was assessed on the basis of objective (dryness, 0–1 pad/24 h or >20 g/24 h pad test) and subjective results (PGI-I). We performed the Wilcoxon rank sum test, Fisher’s exact test, logistic regression, and multivariate analysis. (3) Results: The study included 88 patients from 9 centers with a mean age of 71.3 years. No Clavien–Dindo > II complications occurred within the first 3 months after ATOMS implantation. A total of 10 cases (9%) required revision in the ensuing clinical course. After a mean follow-up of 42.5 months, 76.1% achieved social continence, and 56.8% used no pads at all. Mean urine leakage/24 h dropped from 422 g (3.9 pads) to 38 g (0.69 pads) and the mean ICIQ-SF decreased from 16.25 to 5.3 (p < 0.0001). PROMs (patient-reported outcome measures) showed improvement in 98.9% of cases, and 63.6% gave a “very much better” PGI-I rating. Multivariate analysis identified a lower probability of achieving maximum satisfaction for the following factors: the AdVance XP as first-line therapy (OR 0.35), a lower ICIQ-SF question 1 (OR 0.26), status post-irradiation (OR 0.14), and more severe pain prior to ATOMS implantation (OR 0.51). (4) Conclusions: Implantation of an ATOMS is an effective and safe second-line treatment option for recurrent urinary incontinence after implantation of an AdVance/AdVance XP sling. High patient satisfaction was demonstrated in a long-term follow-up

    Usefulness of bone turnover markers as predictors of mortality risk, disease progression and skeletal-related events appearance in patients with prostate cancer with bone metastases following treatment with zoledronic acid: TUGAMO study

    Full text link
    Owing to the limited validity of clinical data on the treatment of prostate cancer (PCa) and bone metastases, biochemical markers are a promising tool for predicting survival, disease progression and skeletal-related events (SREs) in these patients. The aim of this study was to evaluate the predictive capacity of biochemical markers of bone turnover for mortality risk, disease progression and SREs in patients with PCa and bone metastases undergoing treatment with zoledronic acid (ZA). Methods: This was an observational, prospective and multicenter study in which ninety-eight patients were included. Patients were treated with ZA (4mg every 4 weeks for 18 months). Data were collected at baseline and 3, 6, 9, 12, 15 and 18 months after the beginning of treatment. Serum levels of bone alkaline phosphtase (BALP), aminoterminal propeptide of procollagen type I (P1NP) and beta-isomer of carboxiterminal telopeptide of collagen I (b-CTX) were analysed at all points in the study. Data on disease progression, SREs development and survival were recorded. Results: Cox regression models with clinical data and bone markers showed that the levels of the three markers studied were predictive of survival time, with b-CTX being especially powerful, in which a lack of normalisation in visit 1 (3 months after the beginning of treatment) showed a 6.3-times more risk for death than in normalised patients. Levels of these markers were also predictive for SREs, although in this case BALP and P1NP proved to be better predictors. We did not find any relationship between bone markers and disease progression. Conclusion: In patients with PCa and bone metastases treated with ZA, b-CTX and P1NP can be considered suitable predictors for mortality risk, while BALP and P1NP are appropriate for SREs. The levels of these biomarkers 3 months after the beginning of treatment are especially importantThis study was supported by Novartis Oncology Spai

    Assessment of a New ROS1 Immunohistochemistry Clone (SP384) for the Identification of ROS1 Rearrangements in Patients with Non–Small Cell Lung Carcinoma: the ROSING Study

    Get PDF
    Introduction: The ROS1 gene rearrangement has become an important biomarker in NSCLC. The College of American Pathologists/International Association for the Study of Lung Cancer/Association for Molecular Pathology testing guidelines support the use of ROS1 immunohistochemistry (IHC) as a screening test, followed by confirmation with fluorescence in situ hybridization (FISH) or a molecular test in all positive results. We have evaluated a novel anti-ROS1 IHC antibody (SP384) in a large multicenter series to obtain real-world data. Methods: A total of 43 ROS1 FISH-positive and 193 ROS1 FISH-negative NSCLC samples were studied. All specimens were screened by using two antibodies (clone D4D6 from Cell Signaling Technology and clone SP384 from Ventana Medical Systems), and the different interpretation criteria were compared with break-apart FISH (Vysis). FISH-positive samples were also analyzed with next-generation sequencing (Oncomine Dx Target Test Panel, Thermo Fisher Scientific). Results: An H-score of 150 or higher or the presence of at least 70% of tumor cells with an intensity of staining of 2+ or higher by the SP384 clone was the optimal cutoff value (both with 93% sensitivity and 100% specificity). The D4D6 clone showed similar results, with an H-score of at least 100 (91% sensitivity and 100% specificity). ROS1 expression in normal lung was more frequent with use of the SP384 clone (p < 0.0001). The ezrin gene (EZR)-ROS1 variant was associated with membranous staining and an isolated green signal FISH pattern (p = 0.001 and p = 0.017, respectively). Conclusions: The new SP384 ROS1 IHC clone showed excellent sensitivity without compromising specificity, so it is another excellent analytical option for the proposed testing algorithm

    Estudio comparativo aleatorizado para la evaluación de un nuevo esquema terapéutico de fosfomicina trometamol en mujeres posmenopáusicas con infección no complicada del tracto urinario inferior

    No full text
    Comparación de 2 regímenes terapéuticos en términos de erradicación bacteriana para mujeres posmenopáusicas con cistitis aguda no complicada, que completan el tratamiento antibiótico.1.148 JCR (2013) Q4, 57/75 Urology & nephrolog

    ATOMS (Adjustable Transobturator Male System) Is an Effective and Safe Second-Line Treatment Option for Recurrent Urinary Incontinence after Implantation of an AdVance/AdVance XP Fixed Male Sling? A Multicenter Cohort Analysis

    No full text
    (1) Background: This study examined outcomes of second-line ATOMS implantation after failure of the fixed male sling (FMS) AdVance/AdVance XP. (2) Methods: A retrospective multicenter cohort analysis was carried out in men implanted with an ATOMS between 2011 and 2020 after failure of an AdVance/AdVance XP. Success was assessed on the basis of objective (dryness, 0–1 pad/24 h or >20 g/24 h pad test) and subjective results (PGI-I). We performed the Wilcoxon rank sum test, Fisher’s exact test, logistic regression, and multivariate analysis. (3) Results: The study included 88 patients from 9 centers with a mean age of 71.3 years. No Clavien–Dindo > II complications occurred within the first 3 months after ATOMS implantation. A total of 10 cases (9%) required revision in the ensuing clinical course. After a mean follow-up of 42.5 months, 76.1% achieved social continence, and 56.8% used no pads at all. Mean urine leakage/24 h dropped from 422 g (3.9 pads) to 38 g (0.69 pads) and the mean ICIQ-SF decreased from 16.25 to 5.3 (p < 0.0001). PROMs (patient-reported outcome measures) showed improvement in 98.9% of cases, and 63.6% gave a “very much better” PGI-I rating. Multivariate analysis identified a lower probability of achieving maximum satisfaction for the following factors: the AdVance XP as first-line therapy (OR 0.35), a lower ICIQ-SF question 1 (OR 0.26), status post-irradiation (OR 0.14), and more severe pain prior to ATOMS implantation (OR 0.51). (4) Conclusions: Implantation of an ATOMS is an effective and safe second-line treatment option for recurrent urinary incontinence after implantation of an AdVance/AdVance XP sling. High patient satisfaction was demonstrated in a long-term follow-up
    corecore