6 research outputs found

    Healthcare Utilization and Quality of Life Improvement after Ablation for Paroxysmal AF in Younger and Older Patients

    Get PDF
    Background Atrial fibrillation (AF) prevalence increases significantly with age. Little is known about the effect of AF ablation on quality of life and healthcare utilization in the elderly. The objective of this study was to quantify the healthcare utilization and quality of life benefits of catheter ablation for AF, for patients ≥65 years compared to patients <65 years. Methods Two multicenter U.S. registry studies enrolled patients with paroxysmal AF. Baseline characteristics and acute outcomes were collected for 736 patients receiving catheter ablation with the Navistar® ThermoCool® SF Catheter (Biosense Webster, Inc., Diamond Bar, CA, USA). Healthcare utilization and quality of life outcomes were collected through 1 year postablation for 508 patients. Results The rates of acute pulmonary vein isolation were high and similar between patients ≥65 years and <65 years (97.5% vs 95.8%, P = 0.2130). Length of stay for the index procedure was similar between age groups with 82.2% of the older group and 83.2% of the younger group having one-day hospitalization. Disease-specific quality of life instrument scores improved significantly and similarly for older and younger patients at 1 year postablation, compared to baseline. AF-related hospitalizations and emergency department visits were similar or lower in older patients compared to younger patients, as reported at 1 year postablation. Conclusion For older patients undergoing catheter ablation for paroxysmal AF, healthcare utilization parameters were lower or not significantly different than for younger patients, and quality of life outcomes were similarly improved. These findings support the use of catheter ablation as a treatment option in older patients with paroxysmal AF

    In vivo porcine characterization of atrial lesion safety and efficacy utilizing a circular pulsed-field ablation catheter including assessment of collateral damage to adjacent tissue in supratherapeutic ablation applications.

    No full text
    IntroductionPulsed-field ablation (PFA), an ablative method that causes cell death by irreversible electroporation, has potential safety advantages over radiofrequency ablation and cryoablation. Pulmonary vein (PV) isolation was performed in a porcine model to characterize safety and performance of a novel, fully-integrated biphasic PFA system comprising a multi-channel generator, variable loop circular catheter, and integrated PFA mapping software module.MethodsEight healthy porcine subjects were included. To evaluate safety, multiple ablations were performed, including sites not generally targeted for therapeutic ablation, such as the right inferior PV lumen, right superior PV ostium, and adjacent to the esophagus and phrenic nerve. To evaluate the efficacy, animals were recovered, followed for 30(±3) days, then re-mapped. Gross pathological and histopathological examinations assessed procedural injuries, chronic thrombosis, tissue ablation, penetration depth, healing, and inflammatory response.ResultsAll eight animals survived follow-up. PV narrowing was not observed acutely nor at follow-up, even when ablation was performed deep to the PV ostium. No injury was seen grossly or histologically in adjacent structures. All PVs were durably isolated, confirmed by bidirectional block at re-map procedure. Histological examination showed complete, transmural necrosis around the circumference of the ablated section of right PVs.ConclusionThis preclinical evaluation of a fully-integrated PFA system demonstrated effective and durable ablation of cardiac tissue and PV isolation without collateral damage to adjacent structures, even when ablation was performed in more extreme settings than those used therapeutically. Histological staining confirmed complete transmural cell necrosis around the circumference of the PV ostium at 30 days

    Bibliography

    No full text
    corecore