380 research outputs found

    High sensitivity in situ monitoring of NO3 in an atmospheric simulation chamber using incoherent broadband cavity-enhanced absorption spectroscopy

    Get PDF
    We describe the application of incoherent broadband cavity-enhanced absorption spectroscopy (IBBCEAS) for the in situ detection of atmospheric trace gases and radicals (NO3, NO2, O-3, H2O) in an atmospheric simulation chamber under realistic atmospheric conditions. The length of the optical cavity across the reaction chamber is 4.5 m, which is significantly longer than in previous studies that use high finesse optical cavities to achieve high absorption sensitivity. Using a straightforward spectrometer configuration, we show that detection limits corresponding to typical atmospheric concentrations can be achieved with a measurement time of seconds to a few minutes. In particular, with only moderate reflectivity mirrors, we report a measured sensitivity of 4 pptv to NO3 in a 1 min acquisition time. The high spatial and temporal resolution of the IBBCEAS method and its pptv sensitivity to NO3 makes it useful in laboratory studies of atmospheric processes as well as having obvious potential for field measurements.We describe the application of incoherent broadband cavity-enhanced absorption spectroscopy (IBBCEAS) for the in situ detection of atmospheric trace gases and radicals (NO3, NO2, O-3, H2O) in an atmospheric simulation chamber under realistic atmospheric conditions. The length of the optical cavity across the reaction chamber is 4.5 m, which is significantly longer than in previous studies that use high finesse optical cavities to achieve high absorption sensitivity. Using a straightforward spectrometer configuration, we show that detection limits corresponding to typical atmospheric concentrations can be achieved with a measurement time of seconds to a few minutes. In particular, with only moderate reflectivity mirrors, we report a measured sensitivity of 4 pptv to NO3 in a 1 min acquisition time. The high spatial and temporal resolution of the IBBCEAS method and its pptv sensitivity to NO3 makes it useful in laboratory studies of atmospheric processes as well as having obvious potential for field measurements

    XUV Frequency Combs via Femtosecond Enhancement Cavities

    Full text link
    We review the current state of tabletop extreme ultraviolet (XUV) sources based on high harmonic generation (HHG) in femtosecond enhancement cavities (fsEC). Recent developments have enabled generation of high photon flux (1014 photons/sec) in the XUV, at high repetition rates (>50 MHz) and spanning the spectral region from 40 nm - 120 nm. This level of performance has enabled precision spectroscopy with XUV frequency combs and promises further applications in XUV spectroscopic and photoemission studies. We discuss the theory of operation and experimental details of the fsEC and XUV generation based on HHG, including current technical challenges to increasing the photon flux and maximum photon energy produced by this type of system. Current and future applications for these sources are also discussed.Comment: invited review article, 38 page

    Parasitic fauna in farmed trouts in Tismana, Romania

    Get PDF
    Epidemiological study of the general prevalence of parasites in trouts in the two farms from have revealed various aspects depending on the species studied, depending on season, age category (size) but also from a farm to another

    The Posttraumatic Occlusion of the Vertebral Artery: Case presentation

    Get PDF
    We investigate radiographic features of vertebral artery injury/occlusion associated with nonpenetrating cervical spine trauma and to demonstrate the importance of the CTA in high-risk cases. With the popularization of CTA (Computed Tomography Angiography) and MRA (Magnetic Resonance Angiography), vertebral artery injury has been a common complication of cervical spine trauma. The occlusion of the vertebral artery secondary to non-penetrating trauma of the cervical spine (fractures and/dislocations) can be found in approximately 20% of the cases. Vertebral artery occlusion was rarely symptomatic because of sufficient collateral blood supply through not only contralateral vertebral artery but also the circle of Willis

    Structure functions for the three nucleon system

    Get PDF
    The spectral functions and light-cone momentum distributions of protons and neutrons in 3He and 3H are given in terms of the three-nucleon wave function for realistic nucleon-nucleon interactions. To reduce computational complexity, separable expansions are employed for the nucleon-nucleon potentials. The results for the light-cone momentum distributions suggest that they are not very sensitive to the details of the two-body interaction, as long as it has reasonable short-range repulsion. The unpolarised and polarised structure functions are examined for both 3He and 3H in order to test the usefulness of 3He as a neutron target. It is found that the measurement of the spin structure function of polarised 3H would provide a very clear test of the predicted change in the polarised parton distributions of a bound proton.Comment: 30 pages, REVTeX, 11 figure

    A calibration method for broad-bandwidth cavity enhanced absorption spectroscopy performed with supercontinuum radiation

    Get PDF
    An efficient calibration method has been developed for broad-bandwidth cavity enhanced absorption spectroscopy. The calibration is performed using phase shift cavity ring-down spectroscopy, which is conveniently implemented through use of an acousto-optic tunable filter (AOTF). The AOTF permits a narrowband portion of the SC spectrum to be scanned over the full high-reflectivity bandwidth of the cavity mirrors. After calibration the AOTF is switched off and broad-bandwidth CEAS can be performed with the same light source without any loss of alignment to the set-up. We demonstrate the merits of the method by probing transitions of oxygen molecules O-2 and collisional pairs of oxygen molecules (O-2)(2) in the visible spectral range

    The reference human nuclear mitochondrial sequences compilation validated and implemented on the UCSC genome browser

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Eukaryotic nuclear genomes contain fragments of mitochondrial DNA called NumtS (Nuclear mitochondrial Sequences), whose mode and time of insertion, as well as their functional/structural role within the genome are debated issues. Insertion sites match with chromosomal breaks, revealing that micro-deletions usually occurring at non-homologous end joining <it>loci </it>become reduced in presence of NumtS. Some NumtS are involved in recombination events leading to fragment duplication. Moreover, NumtS are polymorphic, a feature that renders them candidates as population markers. Finally, they are a cause of contamination during human mtDNA sequencing, leading to the generation of false heteroplasmies.</p> <p>Results</p> <p>Here we present RHNumtS.2, the most exhaustive human NumtSome catalogue annotating 585 NumtS, 97% of which were here validated in a European individual and in HapMap samples. The NumtS complete dataset and related features have been made available at the UCSC Genome Browser. The produced sequences have been submitted to INSDC databases. The implementation of the RHNumtS.2 tracks within the UCSC Genome Browser has been carried out with the aim to facilitate browsing of the NumtS tracks to be exploited in a wide range of research applications.</p> <p>Conclusions</p> <p>We aimed at providing the scientific community with the most exhaustive overview on the human NumtSome, a resource whose aim is to support several research applications, such as studies concerning human structural variation, diversity, and disease, as well as the detection of false heteroplasmic mtDNA variants. Upon implementation of the NumtS tracks, the application of the BLAT program on the UCSC Genome Browser has now become an additional tool to check for heteroplasmic artefacts, supported by data available through the NumtS tracks.</p

    The WOMAN Trial (World Maternal Antifibrinolytic Trial): tranexamic acid for the treatment of postpartum haemorrhage: an international randomised, double blind placebo controlled trial

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Each year, worldwide about 530,000 women die from causes related to pregnancy and childbirth. Of the deaths 99% are in low and middle income countries. Obstetric haemorrhage is the leading cause of maternal mortality, most occurring in the postpartum period. Systemic antifibrinolytic agents are widely used in surgery to prevent clot breakdown (fibrinolysis) in order to reduce surgical blood loss. At present there is little reliable evidence from randomised trials on the effectiveness of tranexamic acid in the treatment of postpartum haemorrhage.</p> <p>Methods</p> <p>The Trial aims to determine the effect of early administration of tranexamic acid on mortality, hysterectomy and other morbidities (surgical interventions, blood transfusion, risk of non-fatal vascular events) in women with clinically diagnosed postpartum haemorrhage. The use of health services and safety, especially thromboembolic effect, on breastfed babies will also be assessed. The trial will be a large, pragmatic, randomised, double blind, placebo controlled trial among 15,000 women with a clinical diagnosis of postpartum haemorrhage. All legally adult women with clinically diagnosed postpartum haemorrhage following vaginal delivery of a baby or caesarean section will potentially be eligible. The fundamental eligibility criterion is the responsible clinician's 'uncertainty' as to whether or not to use an antifibrinolytic agent in a particular woman with postpartum haemorrhage. Treatment will entail a dose of tranexamic acid (1 gram by intravenous injection) or placebo (sodium chloride 0.9%) will be given as soon as possible after randomisation. A second dose may be given if after 30 minutes bleeding continues, or if it stops and restarts within 24 hours after the first dose.</p> <p>The main analyses will be on an 'intention to treat' basis, irrespective of whether the allocated treatment was received or not. Subgroup analyses for the primary outcome will be based on type of delivery; administration or not of prophylactic uterotonics; and on whether the clinical decision to consider trial entry was based primarily on estimated blood loss alone or on haemodynamic instability. A study with 15,000 women will have over 90% power to detect a 25% reduction from 4% to 3% in the primary endpoint of mortality or hysterectomy.</p> <p>Trial registration</p> <p>Current Controlled Trials: ISRCTN76912190 and Clinicaltrials.gov ID: NCT00872469</p

    Trace species detection in the near infrared using Fourier transform broadband cavity enhanced absorption spectroscopy: Initial studies on potential breath analytes

    Get PDF
    Cavity enhanced absorption measurements have been made of several species that absorb light between 1.5 and 1.7 µm using both a supercontinuum source and superluminescent light emitting diodes. A system based upon an optical enhancement cavity of relatively high finesse, consisting of mirrors of reflectivity ∼99.98%, and a Fourier transform spectrometer, is demonstrated. Spectra are recorded of isoprene, butadiene, acetone and methane, highlighting problems with spectral interference and unambiguous concentration determinations. Initial results are presented of acetone within a breath-like matrix indicating ppm precision at &lt;∼10 ppm acetone levels. Instrument sensitivities are sufficiently enhanced to enable the detection of atmospheric levels of methane. Higher detection sensitivities are achieved using the supercontinuum source, with a minimum detectable absorption coefficient of ∼4 × 10(-9) cm(-1) reported within a 4 min acquisition time. Finally, two superluminescent light emitting diodes are coupled together to increase the wavelength coverage, and measurements are made simultaneously on acetylene, CO(2), and butadiene. The absorption cross-sections for acetone and isoprene have been measured with an instrumental resolution of 4 cm(-1) and are found to be 1.3 ± 0.1 × 10(-21) cm(2) at a wavelength of 1671.9 nm and 3.6 ± 0.2 × 10(-21) cm(2) at 1624.7 nm, respectively
    corecore