3,692 research outputs found

    Structural Evolution of Electrochemically Lithiated MoS2_{2} Nanosheets and the Role of Carbon Additive in Li-Ion Batteries

    Get PDF
    Understanding the structure and phase changes associated with conversion-type materials is key to optimizing their electrochemical performance in Li-ion batteries. For example, molybdenum disulfide (MoS2_{2}) offers a capacity up to 3-fold higher (∼1 Ah/g) than the currently used graphite anodes, but they suffer from limited Coulombic efficiency and capacity fading. The lack of insights into the structural dynamics induced by electrochemical conversion of MoS2_{2} still hampers its implementation in high energy-density batteries. Here, by combining ab initio\textit{ab initio} density-functional theory (DFT) simulation with electrochemical analysis, we found new sulfur-enriched intermediates that progressively insulate MoS2_{2} electrodes and cause instability from the first discharge cycle. Because of this, the choice of conductive additives is critical for the battery performance. We investigate the mechanistic role of carbon additive by comparing equal loading of standard Super P carbon powder and carbon nanotubes (CNTs). The latter offer a nearly 2-fold increase in capacity and a 45% reduction in resistance along with Coulombic efficiency of over 90%. These insights into the phase changes during MoS2_{2} conversion reactions and stabilization methods provide new solutions for implementing cost-effective metal sulfide electrodes, including Li-S systems in high energy-density batteries.C.G and M.D.V acknowledge the support from ERC starting grant 337739-HIENA. A.J.M. acknowledges the support from the Winton Programme for the Physics of Sustainability. Computational resources were provided by the Cambridge High Performance Computing service. M.H.M acknowledges the support from EPSRC Cambridge NanoDTC, EP/G037221/1

    Transcription profiling reveals potential mechanisms of dysbiosis in the oral microbiome of rhesus macaques with chronic untreated SIV infection.

    Get PDF
    A majority of individuals infected with human immunodeficiency virus (HIV) have inadequate access to antiretroviral therapy and ultimately develop debilitating oral infections that often correlate with disease progression. Due to the impracticalities of conducting host-microbe systems-based studies in HIV infected patients, we have evaluated the potential of simian immunodeficiency virus (SIV) infected rhesus macaques to serve as a non-human primate model for oral manifestations of HIV disease. We present the first description of the rhesus macaque oral microbiota and show that a mixture of human commensal bacteria and "macaque versions" of human commensals colonize the tongue dorsum and dental plaque. Our findings indicate that SIV infection results in chronic activation of antiviral and inflammatory responses in the tongue mucosa that may collectively lead to repression of epithelial development and impact the microbiome. In addition, we show that dysbiosis of the lingual microbiome in SIV infection is characterized by outgrowth of Gemella morbillorum that may result from impaired macrophage function. Finally, we provide evidence that the increased capacity of opportunistic pathogens (e.g. E. coli) to colonize the microbiome is associated with reduced production of antimicrobial peptides

    Quantum control of hybrid nuclear-electronic qubits

    Full text link
    Pulsed magnetic resonance is a wide-reaching technology allowing the quantum state of electronic and nuclear spins to be controlled on the timescale of nanoseconds and microseconds respectively. The time required to flip either dilute electronic or nuclear spins is orders of magnitude shorter than their decoherence times, leading to several schemes for quantum information processing with spin qubits. We investigate instead the novel regime where the eigenstates approximate 50:50 superpositions of the electronic and nuclear spin states forming "hybrid nuclear-electronic" qubits. Here we demonstrate quantum control of these states for the first time, using bismuth-doped silicon, in just 32 ns: this is orders of magnitude faster than previous experiments where pure nuclear states were used. The coherence times of our states are five orders of magnitude longer, reaching 4 ms, and are limited by the naturally-occurring 29Si nuclear spin impurities. There is quantitative agreement between our experiments and no-free-parameter analytical theory for the resonance positions, as well as their relative intensities and relative Rabi oscillation frequencies. In experiments where the slow manipulation of some of the qubits is the rate limiting step, quantum computations would benefit from faster operation in the hybrid regime.Comment: 20 pages, 8 figures, new data and simulation

    Veganism

    Get PDF
    Narrowly understood, veganism is the practice of excluding all animal products from one’s diet, with the exception of human milk. More broadly, veganism is not only a food ethics, but it encompasses all other areas of life. As defined by the Vegan Society when it became an established charity in the UK in 1979, veganism is best understood as “a philosophy and way of living which seeks to exclude – as far as is possible and practicable – all forms of exploitation of, and cruelty to, animals for food, clothing or any other purpose; and by extension, promotes the development and use of animal-free alternatives for the benefit of humans, animals and the environment”. There are two main moral justifications for veganism, both of which rely on a common assumption: that sentience, i.e., the capacity to feel pleasure and pain, is the necessary and sufficient trait to be morally considerable. In what follows, I present these two justifications and a third one which, although less popular, captures some core intuitions among vegans. I then present a challenge faced by veganism and two arguments that reject it as discriminatory, and briefly conclude

    The epidemiology of injuries across the weight-training sports

    Get PDF
    Background: Weight-training sports, including weightlifting, powerlifting, bodybuilding, strongman, Highland Games, and CrossFit, are weight-training sports that have separate divisions for males and females of a variety of ages, competitive standards, and bodyweight classes. These sports may be considered dangerous because of the heavy loads commonly used in training and competition. Objectives: Our objective was to systematically review the injury epidemiology of these weight-training sports, and, where possible, gain some insight into whether this may be affected by age, sex, competitive standard, and bodyweight class. Methods: We performed an electronic search using PubMed, SPORTDiscus, CINAHL, and Embase for injury epidemiology studies involving competitive athletes in these weight-training sports. Eligible studies included peer-reviewed journal articles only, with no limit placed on date or language of publication. We assessed the risk of bias in all studies using an adaption of the musculoskeletal injury review method. Results: Only five of the 20 eligible studies had a risk of bias score ≥75 %, meaning the risk of bias in these five studies was considered low. While 14 of the studies had sample sizes >100 participants, only four studies utilized a prospective design. Bodybuilding had the lowest injury rates (0.12–0.7 injuries per lifter per year; 0.24–1 injury per 1000 h), with strongman (4.5–6.1 injuries per 1000 h) and Highland Games (7.5 injuries per 1000 h) reporting the highest rates. The shoulder, lower back, knee, elbow, and wrist/hand were generally the most commonly injured anatomical locations; strains, tendinitis, and sprains were the most common injury type. Very few significant differences in any of the injury outcomes were observed as a function of age, sex, competitive standard, or bodyweight class. Conclusion: While the majority of the research we reviewed utilized retrospective designs, the weight-training sports appear to have relatively low rates of injury compared with common team sports. Future weight-training sport injury epidemiology research needs to be improved, particularly in terms of the use of prospective designs, diagnosis of injury, and changes in risk exposure

    Development and use of a computer program to detect potentially inappropriate prescribing in older adults residing in Canadian long-term care facilities

    Get PDF
    BACKGROUND: Inappropriate prescribing has been estimated to be as high as 40% in long-term care. The purpose of this study was to develop a computer program that identifies potentially inappropriate drug prescriptions and to test its reliability. METHODS: Potentially inappropriate prescriptions were identified based on modified McLeod guidelines. A database from one pharmacy servicing long-term care facilities in Ontario was utilized for this cross-sectional study. Prescription information was available for the 356 long-term care residents and included: the date the prescription was filled, the quantity of drug prescribed and the eight-digit drug identification number. The pharmacy database was linked to the computer-based program for targeting potential inappropriate prescriptions. The computer program's reliability was assessed by comparing its results to a manual search conducted by two independent research assistants. RESULTS: There was complete agreement between the computer and manual abstraction for the total number of potentially inappropriate prescriptions detected. In total, 83 potentially inappropriate prescriptions were identified. Fifty-three residents (14.9%) received at least one potentially inappropriate prescription. Of those, twenty (37.7%) received two potential inappropriate prescriptions and eight (15.1%) received 3 or more potential inappropriate prescriptions. The most common potential inappropriate prescriptions were identified as long-term use of non-steroidal anti-inflammatory agents and tricyclic antidepressants with active metabolites. CONCLUSION: A computer program can accurately and automatically detect inappropriate prescribing in residents of long-term care facilities. This tool may be used to identify potentially inappropriate drug combinations and educate health care professionals

    Site-specific perturbations of alpha-synuclein fibril structure by the Parkinson's disease associated mutations A53T and E46K.

    Get PDF
    PMCID: PMC3591419This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.Parkinson's disease (PD) is pathologically characterized by the presence of Lewy bodies (LBs) in dopaminergic neurons of the substantia nigra. These intracellular inclusions are largely composed of misfolded α-synuclein (AS), a neuronal protein that is abundant in the vertebrate brain. Point mutations in AS are associated with rare, early-onset forms of PD, although aggregation of the wild-type (WT) protein is observed in the more common sporadic forms of the disease. Here, we employed multidimensional solid-state NMR experiments to assess A53T and E46K mutant fibrils, in comparison to our recent description of WT AS fibrils. We made de novo chemical shift assignments for the mutants, and used these chemical shifts to empirically determine secondary structures. We observe significant perturbations in secondary structure throughout the fibril core for the E46K fibril, while the A53T fibril exhibits more localized perturbations near the mutation site. Overall, these results demonstrate that the secondary structure of A53T has some small differences from the WT and the secondary structure of E46K has significant differences, which may alter the overall structural arrangement of the fibrils

    Influence of Matrix Polarity on the Properties of Ethylene Vinyl Acetate–Carbon Nanofiller Nanocomposites

    Get PDF
    A series of ethylene vinyl acetate (EVA) nanocomposites using four kinds of EVA with 40, 50, 60, and 70 wt% vinyl acetate (VA) contents and three different carbon-based nanofillers—expanded graphite (EG), multi-walled carbon nanotube (MWCNT), and carbon nanofiber (CNF) have been prepared via solution blending. The influence of the matrix polarity and the nature of nanofillers on the morphology and properties of EVA nanocomposites have been investigated. It is observed that the sample with lowest vinyl acetate content exhibits highest mechanical properties. However, the enhancement in mechanical properties with the incorporation of various nanofillers is the highest for EVA with high VA content. This trend has been followed in both dynamic mechanical properties and thermal conductivity of the nanocomposites. EVA copolymer undergoes a transition from partial to complete amorphousness between 40 and 50 wt% VA content, and this changes the dispersion of the nanofillers. The high VA-containing polymers show more affinity toward fillers due to the large free volume available and allow easy dispersion of nanofillers in the amorphous rubbery phase, as confirmed from the morphological studies. The thermal stability of the nanocomposites is also influenced by the type of nanofiller

    A pilot study using tactile cueing for gait rehabilitation following stroke

    Get PDF
    Recovery of walking function is a vital goal of post-stroke rehabilitation. Cueing using audio metronomes has been shown to improve gait, but can be impractical when interacting with others, particularly outdoors where awareness of vehicles and bicycles is essential. Audio is also unsuitable in environments with high background noise, or for those with a hearing impairment. If successful, lightweight portable tactile cueing has the potential to take the benefits of cueing out of the laboratory and into everyday life. The Haptic Bracelets are lightweight wireless devices containing a computer, accelerometers and low-latency vibrotactiles with a wide dynamic range. In this paper we review gait rehabilitation problems and existing solutions, and present an early pilot in which the Haptic Bracelets were applied to post-stroke gait rehabilitation. Tactile cueing during walking was well received in the pilot, and analysis of motion capture data showed immediate improvements in gait
    corecore