591 research outputs found

    Analysis and calibration of absorptive images of Bose-Einstein condensate at non-zero temperatures

    Full text link
    We describe the method allowing quantitative interpretation of absorptive images of mixtures of BEC and thermal atoms which reduces possible systematic errors associated with evaluation of the contribution of each fraction. By using known temperature dependence of the BEC fraction, the analysis allows precise calibration of the fitting results. The developed method is verified in two different measurements and compares well with theoretical calculations and with measurements performed by another group.Comment: 17 pages, 8 figure

    Optic nerve head three-dimensional shape analysis

    Get PDF
    We present a method for optic nerve head (ONH) 3-D shape analysis from retinal optical coherence tomography (OCT). The possibility to noninvasively acquire in vivo high-resolution 3-D volumes of the ONH using spectral domain OCT drives the need to develop tools that quantify the shape of this structure and extract information for clinical applications. The presented method automatically generates a 3-D ONH model and then allows the computation of several 3-D parameters describing the ONH. The method starts with a high-resolution OCT volume scan as input. From this scan, the model-defining inner limiting membrane (ILM) as inner surface and the retinal pigment epithelium as outer surface are segmented, and the Bruch's membrane opening (BMO) as the model origin is detected. Based on the generated ONH model by triangulated 3-D surface reconstruction, different parameters (areas, volumes, annular surface ring, minimum distances) of different ONH regions can then be computed. Additionally, the bending energy (roughness) in the BMO region on the ILM surface and 3-D BMO-MRW surface area are computed. We show that our method is reliable and robust across a large variety of ONH topologies (specific to this structure) and present a first clinical application

    The Certification of the Mass Concentrations of Aluminium, Selenium and Zinc in Human Serum, BCR-637, BCR-638, BCR-639.

    Get PDF
    Abstract not availableJRC.D-Institute for Reference Materials and Measurements (Geel

    The Certification of the Mass Concentrations of Lead and Cadmium in Reconstituted Human Blood. BCR-634, BCR-635, BCR-636.

    Get PDF
    Abstract not availableJRC.D-Institute for Reference Materials and Measurements (Geel

    Coherent Control of Magneto-optical Rotation in Inhomogeneously Broadened Medium

    Get PDF
    We extend our earlier investigations [Opt. Commun. {\bf 179}, 97 (2000)] on the enhancement of magneto-optical rotation (MOR) to include inhomogeneous broadening. We introduce a control field that counter-propagates with respect to the probe field. We derive analytical results for the susceptibilities corresponding to the two circular polarization components of the probe field. From the analytical results we identify and numerically demonstrate the region of parameters where significantly large magneto-optical rotation (MOR) can be obtained. From the numerical results we isolate the significance of the magnetic field and the control field in enhancement of MOR. The control field opens up many new regions of the frequencies of the probe where large magneto-optical rotation occurs. We also report that a large enhancement of MOR can be obtained by operating the probe and control field in two-photon resonance condition.Comment: REVTex format, 14 pages including 6 figures, to be published in Optics Communication

    Strontium optical lattice clocks for practical realization of the metre and secondary representation of the second

    Full text link
    We present a system of two independent strontium optical lattice standards probed with a single shared ultra-narrow laser. The absolute frequency of the clocks can be verified by the use of Er:fiber optical frequency comb with the GPS-disciplined Rb frequency standard. We report hertz-level spectroscopy of the clock line and measurements of frequency stability of the two strontium optical lattice clocks.Comment: This is an author-created, un-copyedited version of an article accepted for publication in Meas. Sci. Technol. The publisher is not responsible for any errors or omissions in this version of the manuscript or any version derived from it. The Version of Record is available online at doi:10.1088/0957-0233/26/7/07520
    corecore