126 research outputs found

    On understanding the microstructure of SiC/SiC Ceramic Matrix Composites (CMCs) after a material removal process

    Get PDF
    The unique material nature (e.g. hard, brittle, heterogeneous and orthotropic) of SiC-based Ceramic Matrix Composites (CMCs) highly affects the outcomes of machining process by inducing high thermo-mechanical loads during material removal. This can result in severe material damage which in turn causes a reduction of the in-service life of critical structural ceramic components (such as in aero-engines or nuclear reactors). In this study, the phenomenon by which the material removal mechanism during drilling influences the CMC surface integrity are discussed by characterising the fracture and deformation phenomena on the CMC's constituents - i.e. SiC and Si materials. Moreover, the strain induced to the surface, together with the changes in chemical composition are characterised via micro Raman spectroscopy and related to the principles of residual stresses upon cutting. This results in a novel understanding of the material removal process that governs cutting of SiC-based CMCs while emphasising how the different microstructure, morphology and nature of ceramics behave under the same cutting conditions. This study has therefore led to a comprehension of how the microstructure of complex hierarchical ceramic materials such as SiC/SiC CMCs is affected by a mechanical cutting process and opens avenues to understand the structure damage under other machining operations (e.g. milling, grinding)

    Determining the Fundamental Failure Modes in Ni-rich Lithium Ion Battery Cathodes

    Full text link
    Challenges associated with in-service mechanical degradation of Li-ion battery cathodes has prompted a transition from polycrystalline to single crystal cathode materials. Whilst for single crystal materials, dislocation-assisted crack formation is assumed to be the dominating failure mechanism throughout battery life, there is little direct information about their mechanical behaviour, and mechanistic understanding remains elusive. Here, we demonstrated, using in situ micromechanical testing, direct measurement of local mechanical properties within LiNi0.8Mn0.1Co0.1O2 single crystalline domains. We elucidated the dislocation slip systems, their critical stresses, and how slip facilitate cracking. We then compared single crystal and polycrystal deformation behaviour. Our findings answer two fundamental questions critical to understanding cathode degradation: What dislocation slip systems operate in Ni-rich cathode materials? And how does slip cause fracture? This knowledge unlocks our ability to develop tools for lifetime prediction and failure risk assessment, as well as in designing novel cathode materials with increased toughness in-service

    Laser-induced breakdown spectroscopy for food authentication

    Get PDF
    With the globalisation of food markets, food authentication has become a significant concern worldwide to ensure food safety and to avoid origin and quality fraud. A multi-elemental fingerprint is a powerful tool for detection of adulterants and geographical origin of foods. Laser-induced breakdown spectroscopy (LIBS) is a promising technique that can provide a mineral fingerprint of food products. LIBS allows a rapid, high-throughput, micro-destructive and multi-elemental analysis of a wide range of samples type. It has already been demonstrated by several authors that LIBS can be successfully used for food authentication. Although LIBS shows excellent potential for at-line or portable applications, improvement in sensitivity of trace elements detection, sample preparation, data analysis and instrument miniaturisation are needed

    Rapid analysis of magnesium in infant formula powder using laser-induced breakdown spectroscopy

    Get PDF
    Laser-induced breakdown spectroscopy (LIBS) was investigated to determine magnesium (Mg) content in infant formula powder. To predict Mg content in the range established by the Codex Alimentarius, a partial least squares regression (PLSR) model was developed using a calibration data set (n = 30) based on full cross-validation and validated using an independent validation data set (n = 21). The prediction model performance was evaluated using the regression coefficients of determination (Rcv2 = 0.94 and Rp2 = 0.85) with the root mean square errors on cross-validation and prediction (RMSECV = 60 mg kg−1 and RMSEP = 80 mg kg−1). The limit of detection (150 mg kg−1) was also calculated. In addition, LIBS successfully predicted the Mg content distributed within a pellet. This study demonstrated that LIBS is suitable as a rapid reagent-free method for the quantification of Mg in powdered infant formula and can provide spatial information with acceptable accuracy

    Quantification of calcium in infant formula using laser-induced breakdown spectroscopy (LIBS), Fourier transform mid-infrared (FT-IR) and Raman spectroscopy combined with chemometrics including data fusion

    Get PDF
    peer-reviewedLaser-induced breakdown spectroscopy (LIBS), Fourier transform mid-infrared (FT-IR) and Raman spectroscopy combined with chemometrics were investigated to quantify calcium (Ca) content in infant formula powder (INF). INF samples (n = 51) with calcium content levels (ca. 6.5–30 mg Ca/100 kJ) were prepared in accordance with the guidelines of Commission Directive 2006/125/EC. Atomic absorption spectroscopy (AAS) was used as the reference method for Ca content determination. To predict Ca content in INF samples, partial least squares regression (PLSR) models that developed based on LIBS, Raman and FT-IR spectral data, respectively. The model developed using LIBS data achieved the best performance for the quantification of Ca content in INF (R2 (cross-validation (CV))-0.99, RMSECV-0.29 mg/g; R2 (prediction (P))-1, RMSEP-0.63 mg/g). PLSR models that developed based on data fusion of Raman and FT-IR spectral features obtained the second best performance (R2CV-0.97, RMSECV-0.38 mg/g; R2P-0.97, RMSEP-0.36 mg/g). This study demonstrated the potential of LIBS, FT-IR and Raman spectroscopy to accurately quantify Ca content in INF.Department of Agriculture, Food and the Marine, Irelan

    Sampling effects on the quantification of sodium content in infant formula using laser induced breakdown spectroscopy (LIBS)

    Get PDF
    Laser-induced breakdown spectroscopy (LIBS) was employed to predict the sodium content of infant formula (IF) over the range 0.5–4 mg Na g−1. Calibration models were built using partial least squares regression (PLS), correlating the LIBS spectral data with reference Na content quantified by atomic absorption spectroscopy (AAS). The main aim of this study was to demonstrate the ability of LIBS as a rapid tool for quantifying sodium in IF, but also to explore strategies concerning the acquisition and pre-processing of LIBS spectra. A range of different pre-processing techniques, measuring depths (repetition of laser shots) and accumulations were conducted and evaluated in terms of PLS performance. The best calibration model was developed using the third-layer spectra normalised by the H I 656.29 nm emission line, yielding a coefficient of determination (R2) of 0.93, and root-mean-square errors (RMSE) of 0.37 and 0.13 mg g−1 for cross-validation and validation, respectively

    Transiting exoplanets from the CoRoT space mission VIII. CoRoT-7b: the first Super-Earth with measured radius

    Get PDF
    We report the discovery of very shallow (DF/F = 3.4 10-4), periodic dips in the light curve of an active V = 11.7 G9V star observed by the CoRoT satellite, which we interpret as due to the presence of a transiting companion. We describe the 3-colour CoRoT data and complementary ground-based observations that support the planetary nature of the companion. Methods. We use CoRoT color information, good angular resolution ground-based photometric observations in- and out- of transit, adaptive optics imaging, near-infrared spectroscopy and preliminary results from Radial Velocity measurements, to test the diluted eclipsing binary scenarios. The parameters of the host star are derived from optical spectra, which were then combined with the CoRoT light curve to derive parameters of the companion. We examine carefully all conceivable cases of false positives, and all tests performed support the planetary hypothesis. Blends with separation larger than 0.40 arcsec or triple systems are almost excluded with a 8 10-4 risk left. We conclude that, as far as we have been exhaustive, we have discovered a planetary companion, named CoRoT-7b, for which we derive a period of 0.853 59 +/- 3 10-5 day and a radius of Rp = 1.68 +/- 0.09 REarth. Analysis of preliminary radial velocity data yields an upper limit of 21 MEarth for the companion mass, supporting the finding. CoRoT-7b is very likely the first Super-Earth with a measured radius.Comment: Accepted in Astronomy and Astrophysics; typos and language corrections; version sent to the printer w few upgrade

    Efficacy and safety of once-daily aclidinium in chronic obstructive pulmonary disease

    Get PDF
    BACKGROUND: The long-term efficacy and safety of aclidinium bromide, a novel, long-acting muscarinic antagonist, were investigated in patients with moderate to severe chronic obstructive pulmonary disease (COPD). METHODS: In two double-blind, 52-week studies, ACCLAIM/COPD I (n=843) and II (n=804), patients were randomised to inhaled aclidinium 200 μg or placebo once-daily. Patients were required to have a post-bronchodilator forced expiratory volume in 1 second (FEV1)/forced vital capacity ratio of ≤70% and FEV1<80% of the predicted value. The primary endpoint was trough FEV1 at 12 and 28 weeks. Secondary endpoints were health status measured by St George's Respiratory Questionnaire (SGRQ) and time to first moderate or severe COPD exacerbation. RESULTS: At 12 and 28 weeks, aclidinium improved trough FEV1 versus placebo in ACCLAIM/COPD I (by 61 and 67 mL; both p<0.001) and ACCLAIM/COPD II (by 63 and 59 mL; both p<0.001). More patients had a SGRQ improvement≥4 units at 52 weeks with aclidinium versus placebo in ACCLAIM/COPD I (48.1% versus 39.5%; p=0.025) and ACCLAIM/COPD II (39.0% versus 32.8%; p=0.074). The time to first exacerbation was significantly delayed by aclidinium in ACCLAIM/COPD II (hazard ratio [HR] 0.7; 95% confidence interval [CI] 0.55 to 0.92; p=0.01), but not ACCLAIM/COPD I (HR 1.0; 95% CI 0.72 to 1.33; p=0.9). Adverse events were minor in both studies. CONCLUSION: Aclidinium is effective and well tolerated in patients with moderate to severe COPD
    • …
    corecore